Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gingold, E. L.
Right arrow Articles by Barnes, G. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gingold, E. L.
Right arrow Articles by Barnes, G. T.

Radiology, Vol 195, 639-644, Copyright © 1995 by Radiological Society of North America


ARTICLES

Contrast and dose with Mo-Mo, Mo-Rh, and Rh-Rh target-filter combinations in mammography

EL Gingold, X Wu and GT Barnes
Department of Radiology, University of Alabama Hospitals and Clinics, University of Alabama at Birmingham, USA.

PURPOSE: To study the effect of three mammography target-filter combinations on contrast and dose. MATERIALS AND METHODS: With screen- film sensitometry, the contrast of a calcification target embedded in simulated breast tissue was measured for three target-filter combinations--molybdenum-molybdenum (Mo-Mo), molybdenum rhodium (Mo- Rh), and rhodium-rhodium (Rh-Rh)--as a function of x-ray tube potential, breast thickness, and breast composition. The corresponding average glandular tissue doses were also determined. RESULTS: Contrast and dose decreased with increasing kilovolt peak with all three target- filter combinations. Contrast was highest for Mo-Mo and lowest for Rh- Rh for images exposed with a low kilovoltage (< 29 kVp). For thick or radiographically dense phantoms, the contrast produced with Mo-Mo was less than or equal to that produced by the other two x-ray spectra when a higher kilovoltage (> or = 29 kVp) was selected. Average glandular dose was greatest for Mo-Mo and lowest for Rh-Rh for all phantom thicknesses, breast compositions, and tube potentials studied. CONCLUSIONS: For the thick or dense breast, the alternative target- filter selections can achieve contrast comparable to or better than that obtainable with Mo-Mo while using a smaller dose.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. K. Nishino, X. Wu, and R. F. Johnson Jr.
Thickness of Molybdenum Filter and Squared Contrast-to-Noise Ratio per Dose for Digital Mammography
Am. J. Roentgenol., October 1, 2005; 185(4): 960 - 963.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Boone
Glandular Breast Dose for Monoenergetic and High-Energy X-ray Beams: Monte Carlo Assessment
Radiology, October 1, 1999; 213(1): 23 - 37.
[Abstract] [Full Text]


Home page
RadiologyHome page
P. S. Rezentes, A. de Almeida, and G. T. Barnes
Mammography Grid Performance
Radiology, January 1, 1999; 210(1): 227 - 232.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.