|
|
||||||||
Radiology, Vol 195, 805-814, Copyright © 1995 by Radiological Society of North America
ARTICLES |
JF Schenck, FA Jolesz, PB Roemer, HE Cline, WE Lorensen, R Kikinis, SG Silverman, CJ Hardy, WD Barber and ET Laskaris
General Electric Corporate Research and Development Center, General Electric Co, Schenectady, NY 12309, USA.
PURPOSE: To develop a superconducting magnetic resonance (MR) imager that provides direct access to the patient and permits interactive MR- guided interventional procedures. MATERIALS AND METHODS: A 0.5-T superconducting magnet that allows a region of vertical access to the patient was designed and constructed. This magnet was integrated with newly designed shielded gradient coils, flexible surface coils, and nonmagnetic displays and with position-monitoring probes and device- tracking instrumentation. RESULTS: The magnet homogeneity was 12.3 ppm, and the gradient field was linear to within 1% over an imaging region 30 cm in diameter. The signal-to-noise ratio was 10% higher than in a comparable 0.5-T superconducting imager. Images were obtained in several anatomic regions with use of routine pulse sequences. Interactive image plane selection and near real-time imaging, with use of fast gradient-recalled echo sequences, were demonstrated at a rate of one image every 1.5 seconds. CONCLUSION: MR-guided interventional procedures can be performed with full patient access with use of an open-configuration, superconducting MR magnet with near real-time imaging and interactive image plane control.
This article has been cited by other articles:
![]() |
J. S. Lewin, S. G. Nour, M. L. Meyers, A. K. Metzger, R. J. Maciunas, M. Wendt, J. L. Duerk, A. Oppelt, and W. R. Selman Intraoperative MRI with a Rotating, Tiltable Surgical Table: A Time Use Study and Clinical Results in 122 Patients Am. J. Roentgenol., November 1, 2007; 189(5): 1096 - 1103. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Carrino, B. Khurana, J. E. Ready, S. G. Silverman, and C. S. Winalski Magnetic Resonance Imaging-Guided Percutaneous Biopsy of Musculoskeletal Lesions J. Bone Joint Surg. Am., October 1, 2007; 89(10): 2179 - 2187. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Tuncali, P. R. Morrison, C. S. Winalski, J. A. Carrino, S. Shankar, J. E. Ready, E. vanSonnenberg, and S. G. Silverman MRI-Guided Percutaneous Cryotherapy for Soft-Tissue and Bone Metastases: Initial Experience Am. J. Roentgenol., July 1, 2007; 189(1): 232 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Geva and A. C. Marshall Magnetic Resonance Imaging-Guided Catheter Interventions in Congenital Heart Disease Circulation, February 28, 2006; 113(8): 1051 - 1052. [Full Text] [PDF] |
||||
![]() |
S. G. Silverman, K. Tuncali, E. vanSonnenberg, P. R. Morrison, S. Shankar, N. Ramaiya, and J. P. Richie Renal Tumors: MR Imaging-guided Percutaneous Cryotherapy--Initial Experience in 23 Patients Radiology, August 1, 2005; 236(2): 716 - 724. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. K. Wacker, K. Reither, W. Ebert, M. Wendt, J. S. Lewin, and K.-J. Wolf MR Image-guided Endovascular Procedures with the Ultrasmall Superparamagnetic Iron Oxide SH U 555 C as an Intravascular Contrast Agent: Study in Pigs Radiology, February 1, 2003; 226(2): 459 - 464. [Abstract] [Full Text] [PDF] |
||||
![]() |
E A Dick, S D Taylor-Robinson, H C Thomas, and W M W Gedroyc Ablative therapy for liver tumours Gut, May 1, 2002; 50(5): 733 - 739. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Steiner, S. K. Koskinen, C. S. Winalski, S. D. Martin, and M. Haymen Dynamic Lateral Patellar Tilt in the Anterior Cruciate Ligament-Deficient Knee: A Magnetic Resonance Imaging Analysis Am. J. Sports Med., September 1, 2001; 29(5): 593 - 599. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Hata, M. Jinzaki, D. Kacher, R. Cormak, D. Gering, A. Nabavi, S. G. Silverman, A. V. D'Amico, R. Kikinis, F. A. Jolesz, et al. MR Imaging-guided Prostate Biopsy with Surgical Navigation Software: Device Validation and Feasibility Radiology, July 1, 2001; 220(1): 263 - 268. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. C. Tempany and B. J. McNeil Advances in Biomedical Imaging JAMA, February 7, 2001; 285(5): 562 - 567. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Schneider, T. Schulz, F. Schmidt, J. Dietrich, S. Lieberenz, C. Trantakis, V. Seifert, S. Kellermann, R. Schober, L. Schaffranietz, et al. Gross-total Surgery of Supratentorial Low-grade Gliomas under Intraoperative MR Guidance AJNR Am. J. Neuroradiol., January 1, 2001; 22(1): 89 - 98. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Silverman, K. Tuncali, D. F. Adams, E. vanSonnenberg, K. H. Zou, D. F. Kacher, P. R. Morrison, and F. A. Jolesz MR Imaging-guided Percutaneous Cryotherapy of Liver Tumors: Initial Experience Radiology, December 1, 2000; 217(3): 657 - 664. [Abstract] [Full Text] |
||||
![]() |
W. J. Rogers, J. W. Prichard, Y.-L. Hu, P. R. Olson, D. H. Benckart, C. M. Kramer, D. A. Vido, and N. Reichek Characterization of Signal Properties in Atherosclerotic Plaque Components by Intravascular MRI Arterioscler. Thromb. Vasc. Biol., July 1, 2000; 20(7): 1824 - 1830. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Martin, W. A. Hall, H. Liu, C. H. Pozza, E. Michel, S. O. Casey, R. E. Maxwell, and C. L. Truwit Brain Tumor Resection: Intraoperative Monitoring with High-Field-Strength MR Imaging-Initial Results Radiology, April 1, 2000; 215(1): 221 - 228. [Abstract] [Full Text] |
||||
![]() |
D. Jaramillo, T. A. Galen, C. S. Winalski, J. DiCanzio, D. Zurakowski, R. V. Mulkern, P. A. McDougall, O. L. Villegas-Medina, F. A. Jolesz, and J. R. Kasser Legg-Calve-Perthes Disease: MR Imaging Evaluation during Manual Positioning of the Hip—Comparison with Conventional Arthrography Radiology, August 1, 1999; 212(2): 519 - 525. [Abstract] [Full Text] |
||||
![]() |
J. Lewin Interventional MR Imaging: Concepts, Systems, and Applications in AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 735 - 748. [Full Text] |
||||
![]() |
R. B. Schwartz, L. Hsu, T. Z. Wong, D. F. Kacher, A. A. Zamani, P. M. Black, E. A. III, P. E. Stieg, T. M. Moriarty, C. A. Martin, et al. Intraoperative MR Imaging Guidance for Intracranial Neurosurgery: Experience with the First 200 Cases Radiology, May 1, 1999; 211(2): 477 - 488. [Abstract] [Full Text] |
||||
![]() |
G. G. Zimmermann-Paul, H. H. Quick, P. Vogt, G. K. von Schulthess, D. Kling, and J. F. Debatin High-Resolution Intravascular Magnetic Resonance Imaging : Monitoring of Plaque Formation in Heritable Hyperlipidemic Rabbits Circulation, March 2, 1999; 99(8): 1054 - 1061. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Genant, J. E. Vandevenne, A. G. Bergman, C. F. Beaulieu, S. T. Kee, A. M. Norbash, and P. Lang Interventional Musculoskeletal Procedures Performed by Using MR Imaging Guidance with a Vertically Open MR Unit: Assessment of Techniques and Applicability Radiology, April 1, 2002; 223(1): 127 - 136. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |