Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schenck, J. F.
Right arrow Articles by Laskaris, E. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schenck, J. F.
Right arrow Articles by Laskaris, E. T.

Radiology, Vol 195, 805-814, Copyright © 1995 by Radiological Society of North America


ARTICLES

Superconducting open-configuration MR imaging system for image-guided therapy

JF Schenck, FA Jolesz, PB Roemer, HE Cline, WE Lorensen, R Kikinis, SG Silverman, CJ Hardy, WD Barber and ET Laskaris
General Electric Corporate Research and Development Center, General Electric Co, Schenectady, NY 12309, USA.

PURPOSE: To develop a superconducting magnetic resonance (MR) imager that provides direct access to the patient and permits interactive MR- guided interventional procedures. MATERIALS AND METHODS: A 0.5-T superconducting magnet that allows a region of vertical access to the patient was designed and constructed. This magnet was integrated with newly designed shielded gradient coils, flexible surface coils, and nonmagnetic displays and with position-monitoring probes and device- tracking instrumentation. RESULTS: The magnet homogeneity was 12.3 ppm, and the gradient field was linear to within 1% over an imaging region 30 cm in diameter. The signal-to-noise ratio was 10% higher than in a comparable 0.5-T superconducting imager. Images were obtained in several anatomic regions with use of routine pulse sequences. Interactive image plane selection and near real-time imaging, with use of fast gradient-recalled echo sequences, were demonstrated at a rate of one image every 1.5 seconds. CONCLUSION: MR-guided interventional procedures can be performed with full patient access with use of an open-configuration, superconducting MR magnet with near real-time imaging and interactive image plane control.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. S. Lewin, S. G. Nour, M. L. Meyers, A. K. Metzger, R. J. Maciunas, M. Wendt, J. L. Duerk, A. Oppelt, and W. R. Selman
Intraoperative MRI with a Rotating, Tiltable Surgical Table: A Time Use Study and Clinical Results in 122 Patients
Am. J. Roentgenol., November 1, 2007; 189(5): 1096 - 1103.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. A. Carrino, B. Khurana, J. E. Ready, S. G. Silverman, and C. S. Winalski
Magnetic Resonance Imaging-Guided Percutaneous Biopsy of Musculoskeletal Lesions
J. Bone Joint Surg. Am., October 1, 2007; 89(10): 2179 - 2187.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Tuncali, P. R. Morrison, C. S. Winalski, J. A. Carrino, S. Shankar, J. E. Ready, E. vanSonnenberg, and S. G. Silverman
MRI-Guided Percutaneous Cryotherapy for Soft-Tissue and Bone Metastases: Initial Experience
Am. J. Roentgenol., July 1, 2007; 189(1): 232 - 239.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Geva and A. C. Marshall
Magnetic Resonance Imaging-Guided Catheter Interventions in Congenital Heart Disease
Circulation, February 28, 2006; 113(8): 1051 - 1052.
[Full Text] [PDF]


Home page
RadiologyHome page
S. G. Silverman, K. Tuncali, E. vanSonnenberg, P. R. Morrison, S. Shankar, N. Ramaiya, and J. P. Richie
Renal Tumors: MR Imaging-guided Percutaneous Cryotherapy--Initial Experience in 23 Patients
Radiology, August 1, 2005; 236(2): 716 - 724.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. K. Wacker, K. Reither, W. Ebert, M. Wendt, J. S. Lewin, and K.-J. Wolf
MR Image-guided Endovascular Procedures with the Ultrasmall Superparamagnetic Iron Oxide SH U 555 C as an Intravascular Contrast Agent: Study in Pigs
Radiology, February 1, 2003; 226(2): 459 - 464.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
E A Dick, S D Taylor-Robinson, H C Thomas, and W M W Gedroyc
Ablative therapy for liver tumours
Gut, May 1, 2002; 50(5): 733 - 739.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
M. E. Steiner, S. K. Koskinen, C. S. Winalski, S. D. Martin, and M. Haymen
Dynamic Lateral Patellar Tilt in the Anterior Cruciate Ligament-Deficient Knee: A Magnetic Resonance Imaging Analysis
Am. J. Sports Med., September 1, 2001; 29(5): 593 - 599.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Hata, M. Jinzaki, D. Kacher, R. Cormak, D. Gering, A. Nabavi, S. G. Silverman, A. V. D'Amico, R. Kikinis, F. A. Jolesz, et al.
MR Imaging-guided Prostate Biopsy with Surgical Navigation Software: Device Validation and Feasibility
Radiology, July 1, 2001; 220(1): 263 - 268.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
C. M. C. Tempany and B. J. McNeil
Advances in Biomedical Imaging
JAMA, February 7, 2001; 285(5): 562 - 567.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. P. Schneider, T. Schulz, F. Schmidt, J. Dietrich, S. Lieberenz, C. Trantakis, V. Seifert, S. Kellermann, R. Schober, L. Schaffranietz, et al.
Gross-total Surgery of Supratentorial Low-grade Gliomas under Intraoperative MR Guidance
AJNR Am. J. Neuroradiol., January 1, 2001; 22(1): 89 - 98.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Silverman, K. Tuncali, D. F. Adams, E. vanSonnenberg, K. H. Zou, D. F. Kacher, P. R. Morrison, and F. A. Jolesz
MR Imaging-guided Percutaneous Cryotherapy of Liver Tumors: Initial Experience
Radiology, December 1, 2000; 217(3): 657 - 664.
[Abstract] [Full Text]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
W. J. Rogers, J. W. Prichard, Y.-L. Hu, P. R. Olson, D. H. Benckart, C. M. Kramer, D. A. Vido, and N. Reichek
Characterization of Signal Properties in Atherosclerotic Plaque Components by Intravascular MRI
Arterioscler. Thromb. Vasc. Biol., July 1, 2000; 20(7): 1824 - 1830.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. J. Martin, W. A. Hall, H. Liu, C. H. Pozza, E. Michel, S. O. Casey, R. E. Maxwell, and C. L. Truwit
Brain Tumor Resection: Intraoperative Monitoring with High-Field-Strength MR Imaging-Initial Results
Radiology, April 1, 2000; 215(1): 221 - 228.
[Abstract] [Full Text]


Home page
RadiologyHome page
D. Jaramillo, T. A. Galen, C. S. Winalski, J. DiCanzio, D. Zurakowski, R. V. Mulkern, P. A. McDougall, O. L. Villegas-Medina, F. A. Jolesz, and J. R. Kasser
Legg-Calve-Perthes Disease: MR Imaging Evaluation during Manual Positioning of the Hip—Comparison with Conventional Arthrography
Radiology, August 1, 1999; 212(2): 519 - 525.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
J. Lewin
Interventional MR Imaging: Concepts, Systems, and Applications in
AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 735 - 748.
[Full Text]


Home page
RadiologyHome page
R. B. Schwartz, L. Hsu, T. Z. Wong, D. F. Kacher, A. A. Zamani, P. M. Black, E. A. III, P. E. Stieg, T. M. Moriarty, C. A. Martin, et al.
Intraoperative MR Imaging Guidance for Intracranial Neurosurgery: Experience with the First 200 Cases
Radiology, May 1, 1999; 211(2): 477 - 488.
[Abstract] [Full Text]


Home page
CirculationHome page
G. G. Zimmermann-Paul, H. H. Quick, P. Vogt, G. K. von Schulthess, D. Kling, and J. F. Debatin
High-Resolution Intravascular Magnetic Resonance Imaging : Monitoring of Plaque Formation in Heritable Hyperlipidemic Rabbits
Circulation, March 2, 1999; 99(8): 1054 - 1061.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. W. Genant, J. E. Vandevenne, A. G. Bergman, C. F. Beaulieu, S. T. Kee, A. M. Norbash, and P. Lang
Interventional Musculoskeletal Procedures Performed by Using MR Imaging Guidance with a Vertically Open MR Unit: Assessment of Techniques and Applicability
Radiology, April 1, 2002; 223(1): 127 - 136.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.