Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McCollough, C. H.
Right arrow Articles by Liu, H. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McCollough, C. H.
Right arrow Articles by Liu, H. H.

Radiology, Vol 196, 153-157, Copyright © 1995 by Radiological Society of North America


ARTICLES

Breast dose during electron-beam CT: measurement with film dosimetry

CH McCollough and HH Liu
Department of Diagnostic Radiology, Rochester, MN 55905, USA.

PURPOSE: To measure the breast dose and dose distribution from examinations performed with electron-beam computed tomography (CT). MATERIALS AND METHODS: Radiographic film was placed bilaterally at three depths in the breasts of an anthropomorphic phantom and exposed with clinically relevant protocols. The average breast dose and the dose distribution were obtained from the digitized and calibrated film and compared with those obtained with conventional CT. RESULTS: Breast doses from electron-beam CT chest, coronary artery calcium, and cardiac function examinations were 21.9, 2.87, and 1.55 mGy, respectively. Within the breast, the dose decreased linearly by a factor of three from the axilla to the sternum. The breast dose from a conventional CT chest examination ranged from 18 to 33 mGy and did not vary substantially across the breast. CONCLUSION: For chest examinations, the average breast dose from an electron-beam CT scanner was comparable to that from conventional CT scanners, despite the differences in dose distribution.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. M. Costantino, G. Randall, M. Gosselin, M. Brandt, K. Spinning, and C. D. Vegas
CT Angiography in the Evaluation of Acute Pulmonary Embolus
Am. J. Roentgenol., August 1, 2008; 191(2): 471 - 474.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. M. Hurwitz, T. T. Yoshizumi, R. E. Reiman, E. K. Paulson, D. P. Frush, G. T. Nguyen, G. I. Toncheva, and P. C. Goodman
Radiation dose to the female breast from 16-MDCT body protocols.
Am. J. Roentgenol., June 1, 2006; 186(6): 1718 - 1722.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. S. Parker, F. K. Hui, M. A. Camacho, J. K. Chung, D. W. Broga, and N. N. Sethi
Female Breast Radiation Exposure During CT Pulmonary Angiography
Am. J. Roentgenol., November 1, 2005; 185(5): 1228 - 1233.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. L. Fricke, L. F. Donnelly, D. P. Frush, T. Yoshizumi, V. Varchena, S. A. Poe, and J. Lucaya
In-Plane Bismuth Breast Shields for Pediatric CT: Effects on Radiation Dose and Image Quality Using Experimental and Clinical Data
Am. J. Roentgenol., February 1, 2003; 180(2): 407 - 411.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
M. M Rehani and M. Berry
Radiation doses in computed tomography
BMJ, March 4, 2000; 320(7235): 593 - 594.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.