Radiology, Vol 196, 153-157, Copyright © 1995 by Radiological Society of North America
ARTICLES |
CH McCollough and HH Liu
Department of Diagnostic Radiology, Rochester, MN 55905, USA.
PURPOSE: To measure the breast dose and dose distribution from examinations performed with electron-beam computed tomography (CT). MATERIALS AND METHODS: Radiographic film was placed bilaterally at three depths in the breasts of an anthropomorphic phantom and exposed with clinically relevant protocols. The average breast dose and the dose distribution were obtained from the digitized and calibrated film and compared with those obtained with conventional CT. RESULTS: Breast doses from electron-beam CT chest, coronary artery calcium, and cardiac function examinations were 21.9, 2.87, and 1.55 mGy, respectively. Within the breast, the dose decreased linearly by a factor of three from the axilla to the sternum. The breast dose from a conventional CT chest examination ranged from 18 to 33 mGy and did not vary substantially across the breast. CONCLUSION: For chest examinations, the average breast dose from an electron-beam CT scanner was comparable to that from conventional CT scanners, despite the differences in dose distribution.
This article has been cited by other articles:
![]() |
M. M. Costantino, G. Randall, M. Gosselin, M. Brandt, K. Spinning, and C. D. Vegas CT Angiography in the Evaluation of Acute Pulmonary Embolus Am. J. Roentgenol., August 1, 2008; 191(2): 471 - 474. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. M. Hurwitz, T. T. Yoshizumi, R. E. Reiman, E. K. Paulson, D. P. Frush, G. T. Nguyen, G. I. Toncheva, and P. C. Goodman Radiation dose to the female breast from 16-MDCT body protocols. Am. J. Roentgenol., June 1, 2006; 186(6): 1718 - 1722. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Parker, F. K. Hui, M. A. Camacho, J. K. Chung, D. W. Broga, and N. N. Sethi Female Breast Radiation Exposure During CT Pulmonary Angiography Am. J. Roentgenol., November 1, 2005; 185(5): 1228 - 1233. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. Fricke, L. F. Donnelly, D. P. Frush, T. Yoshizumi, V. Varchena, S. A. Poe, and J. Lucaya In-Plane Bismuth Breast Shields for Pediatric CT: Effects on Radiation Dose and Image Quality Using Experimental and Clinical Data Am. J. Roentgenol., February 1, 2003; 180(2): 407 - 411. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M Rehani and M. Berry Radiation doses in computed tomography BMJ, March 4, 2000; 320(7235): 593 - 594. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |