Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zambuto, D.
Right arrow Articles by Blickman, J. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zambuto, D.
Right arrow Articles by Blickman, J. G.

Radiology, Vol 196, 55-58, Copyright © 1995 by Radiological Society of North America


ARTICLES

Intracolonic pressure measurements during hydrostatic and air contrast barium enema studies in children

D Zambuto, RT Bramson and JG Blickman
Department of Radiology, Massachusetts General Hospital, Boston, 02114, USA.

PURPOSE: To prospectively evaluate intraluminal pressure changes in the colon of children undergoing conventional hydrostatic (barium and water- soluble contrast material) and air contrast barium enema studies. MATERIALS AND METHODS: Dynamic intracolonic pressure was measured in 26 children undergoing hydrostatic barium (23% wt/vol) enema studies, air contrast barium enema studies, or water-soluble contrast material enema examinations. Measurements were obtained with a measuring device capable of recording rapid changes in pressure. Pressure measurements were obtained with the contrast reservoir system open (contrast material was free to run through the tubing into the patient's colon) and closed (tube was clamped). RESULTS: The colonic pressures during the filling phase with liquid contrast material were equal to those elsewhere at the same level with the hydrostatic system. Mean pressure ranged from 30 to 50 mm Hg with peaks of more than 100 mm Hg during Valsalva maneuvers. During air contrast barium enema studies, sharp pressure increases and rapid swings in the intracolonic pressure occurred during and after manual insufflation of air. CONCLUSION: During conventional hydrostatic barium enema studies, intracolonic pressures remain low. During air insufflation, there were intermittent high, sharp pressure peaks.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
J. H. Lee, S. H. Choi, Y. K. Jeong, W. J. Kwon, A. K. Jeong, B. S. Kang, and S. H. Shin
Intermittent sonographic guidance in air enemas for reduction of childhood intussusception.
J. Ultrasound Med., September 1, 2006; 25(9): 1125 - 1130.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
G. del-Pozo, J. C. Albillos, D. Tejedor, R. Calero, M. Rasero, U. de-la-Calle, and U. Lopez-Pacheco
Intussusception in Children: Current Concepts in Diagnosis and Enema Reduction
RadioGraphics, March 1, 1999; 19(2): 299 - 319.
[Abstract] [Full Text] [PDF]