Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nishimine, K.
Right arrow Articles by Rosch, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nishimine, K.
Right arrow Articles by Rosch, J.

Radiology, Vol 196, 341-347, Copyright © 1995 by Radiological Society of North America


ARTICLES

Improved transjugular intrahepatic portosystemic shunt patency with PTFE-covered stent-grafts: experimental results in swine

K Nishimine, RR Saxon, K Kichikawa, J Mendel-Hartvig, HA Timmermans, HJ Shim, BT Uchida, RE Barton, FS Keller and J Rosch
Dotter Interventional Institute, Oregon Health Sciences University, Portland 97201-3098, USA.

PURPOSE: To evaluate the ability of stent-grafts made with polytetrafluoroethylene (PTFE) graft material to improve transjugular intrahepatic portosystemic shunt (TIPS) patency. MATERIALS AND METHODS: TIPS were created in 13 swine by using PTFE-covered stent-grafts. Uncovered TIPS were placed in 13 other swine. Twenty-one of 26 animals were followed up with portal venography for 3 months or until the shunt became severely stenotic. Five animals without severe stenosis were sacrificed before 3 months because of illness. RESULTS: At 4 weeks after TIPS placement, nine of 13 stent-graft TIPS were patent (< 50% diameter narrowing) compared with only one patent stent in 13 uncovered TIPS. Six of 13 stent-graft TIPS remained patent until the animals were sacrificed. In 11 of 12 uncovered TIPS, stenosis was most prominent in the parenchymal tract. In five of seven stent-graft TIPS, stenosis was most prominent in the hepatic vein above the end of the graft material. Bile leaks were discovered in six occluded uncovered TIPS and in two of the stent-graft TIPS. CONCLUSION: PTFE-covered stent-grafts significantly improved TIPS patency in swine (P < .01). However, stenosis in the hepatic vein led to late shunt malfunction in selected cases.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
G. Maleux, C. Verslype, S. Heye, G. Wilms, G. Marchal, and F. Nevens
Endovascular Shunt Reduction in the Management of Transjugular Portosystemic Shunt-Induced Hepatic Encephalopathy: Preliminary Experience with Reduction Stents and Stent-Grafts
Am. J. Roentgenol., March 1, 2007; 188(3): 659 - 664.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Gandini, D. Konda, and G. Simonetti
Transjugular Intrahepatic Portosystemic Shunt Patency and Clinical Outcome in Patients with Budd-Chiari Syndrome: Covered versus Uncovered Stents
Radiology, October 1, 2006; 241(1): 298 - 305.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Vignali, I. Bargellini, M. Grosso, G. Passalacqua, F. Maglione, F. Pedrazzini, P. Filauri, R. Niola, R. Cioni, and P. Petruzzi
TIPS with Expanded Polytetrafluoroethylene-Covered Stent: Results of an Italian Multicenter Study
Am. J. Roentgenol., August 1, 2005; 185(2): 472 - 480.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. T. Lau, M. Scott, S. W. Stavropoulos, M. C. Soulen, J. A. Solomon, and T. W. I. Clark
Dacron-covered Stent-Grafts in Transjugular Intrahepatic Portosystemic Shunts: Initial Experience
Radiology, August 1, 2005; 236(2): 725 - 729.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G.-J. Teng and Q. Lu
Bile Leakage during Transjugular Intrahepatic Portosystemic Shunt Creation: In Vitro Effect of Bile on Growth and Function of Human Umbilical Vein Endothelium
Radiology, June 1, 2005; 235(3): 867 - 871.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Rossi, F. M. Salvatori, F. Fanelli, M. Bezzi, M. Rossi, G. Marcelli, D. Pepino, O. Riggio, and R. Passariello
Polytetrafluoroethylene-covered Nitinol Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation: 3-year Experience
Radiology, June 1, 2004; 231(3): 820 - 830.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. C. J. ter Borg, M. Hollemans, H. R. van Buuren, F. P. Vleggaar, M. Groeneweg, W. C. J. Hop, and J. S. Lameris
Transjugular Intrahepatic Portosystemic Shunts: Long-term Patency and Clinical Results in a Patient Cohort Observed for 3-9 Years
Radiology, May 1, 2004; 231(2): 537 - 545.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
D. C. Madoff, M. J. Wallace, K. Ahrar, and R. R. Saxon
TIPS-related Hepatic Encephalopathy: Management Options with Novel Endovascular Techniques
RadioGraphics, January 1, 2004; 24(1): 21 - 36.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. J. Wallace, K. Ahrar, L. C. Stephens, and K. C. Wright
Transvenous Extrahepatic Portacaval Shunt: Feasibility Study in a Swine Model
Radiology, July 1, 2003; 228(1): 119 - 125.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Otal, T. Smayra, C. Bureau, J. M. Peron, V. Chabbert, P. Chemla, F. Joffre, J. P. Vinel, and H. Rousseau
Preliminary Results of a New Expanded-Polytetrafluoroethylene--Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Procedures
Am. J. Roentgenol., January 1, 2002; 178(1): 141 - 147.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J D G Rose, S Pimpalwar, and R W Jackson
A new stent-graft for transjugular intrahepatic portosystemic shunts
Br. J. Radiol., October 1, 2001; 74(886): 908 - 912.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. J. Cloft, D. F. Kallmes, H.-B. Lin, S.-T. Li, W. F. Marx, S. B. Hudson, G. A. Helm, M. B. Lopes, J. K. McGraw, J. E. Dion, et al.
Bovine Type I Collagen as an Endovascular Stent-Graft Material: Biocompatibility Study in Rabbits
Radiology, February 1, 2000; 214(2): 557 - 562.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
E. N. Brountzos, E. Alexopoulou, I. Koskinas, L. Thanos, M. A. Papathanasiou, and D. A. Kelekis
Intraperitoneal Portal Vein Bleeding During Transjugular Intrahepatic Portosystemic Shunt: Treatment with Stent-Graft Placement
Am. J. Roentgenol., January 1, 2000; 174(1): 132 - 134.
[Full Text] [PDF]


Home page
RadiologyHome page
Z. J. Haskal
Improved Patency of Transjugular Intrahepatic Portosystemic Shunts in Humans: Creation and Revision with PTFE Stent-Grafts
Radiology, December 1, 1999; 213(3): 759 - 766.
[Abstract] [Full Text]


Home page
RadiologyHome page
Z. J. Haskal and L. H. Brennecke
Transjugular Intrahepatic Portosystemic Shunts Formed with Polyethylene Terephthalate-covered Stents: Experimental Evaluation in Pigs
Radiology, December 1, 1999; 213(3): 853 - 859.
[Abstract] [Full Text]


Home page
RadiologyHome page
M. Cejna, M. Peck-Radosavljevic, S. A. Thurnher, K. Hittmair, M. Schoder, and J. Lammer
Creation of Transjugular Intrahepatic Portosystemic Shunts with Stent-Grafts: Initial Experiences with a Polytetrafluoroethylene-covered Nitinol Endoprosthesis
Radiology, November 1, 2001; 221(2): 437 - 446.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.