|
|
||||||||
Radiology, Vol 196, 371-378, Copyright © 1995 by Radiological Society of North America
ARTICLES |
JJ Snidow, AM Aisen, VJ Harris, SO Trerotola, MS Johnson, AP Sawchuk and MC Dalsing
Department of Radiology, Indiana University Medical Center, Indianapolis 46202-5253, USA.
PURPOSE: To determine if a three-dimensional (3D) gadolinium-enhanced technique is useful for improving the accuracy of magnetic resonance (MR) angiography. MATERIALS AND METHODS: Prospectively, two-dimensional (2D) time-of-flight (TOF) and 3D gadolinium-enhanced MR angiography was performed in 23 patients. Conventional arteriography, the reference standard, was performed in all but five patients. Images from each examination were interpreted blindly by two observers. RESULTS: For common and external iliac arteries, interpretations of dynamic 3D gadolinium-enhanced MR angiograms matched those of conventional arteriograms in 12 of 18 patients (67%) for both observers. Interpretations of 2D TOF images matched those of conventional arteriograms in six (33%) and seven (39%) patients for the two observers respectively. CONCLUSION: Preliminary results suggest that iliac artery MR angiography can be improved by complementing standard 2D TOF acquisitions with 3D gadolinium-enhanced acquisitions.
This article has been cited by other articles:
![]() |
M. Goyen, M. Edelman, P. Perreault, E. O'Riordan, H. Bertoni, J. Taylor, D. Siragusa, M. Sharafuddin, E. R. Mohler III, R. Breger, et al. MR Angiography of Aortoiliac Occlusive Disease: A Phase III Study of the Safety and Effectiveness of the Blood-Pool Contrast Agent MS-325 Radiology, September 1, 2005; 236(3): 825 - 833. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Vogt, W. Ajaj, P. Hunold, C. U. Herborn, H. H. Quick, J. F. Debatin, and S. G. Ruehm Venous Compression at High-Spatial-Resolution Three-dimensional MR Angiography of Peripheral Arteries Radiology, December 1, 2004; 233(3): 913 - 920. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Goyen, H. H. Quick, J. F. Debatin, M. E. Ladd, J. Barkhausen, C. U. Herborn, S. Bosk, H. Kuehl, M. Schleputz, and S. G. Ruehm Whole-Body Three-dimensional MR Angiography with a Rolling Table Platform: Initial Clinical Experience Radiology, July 1, 2002; 224(1): 270 - 277. [Abstract] [Full Text] |
||||
![]() |
M. J. W. Koelemay, J. G. Lijmer, J. Stoker, D. A. Legemate, and P. M. M. Bossuyt Magnetic Resonance Angiography for the Evaluation of Lower Extremity Arterial Disease: A Meta-analysis JAMA, March 14, 2001; 285(10): 1338 - 1345. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Ruehm, C. Corot, P. Vogt, S. Kolb, and J. F. Debatin Magnetic Resonance Imaging of Atherosclerotic Plaque With Ultrasmall Superparamagnetic Particles of Iron Oxide in Hyperlipidemic Rabbits Circulation, January 23, 2001; 103(3): 415 - 422. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Serfaty, P. Chirossel, J. M. Chevallier, R. Ecochard, J. C. Froment, and P. C. Douek Accuracy of Three-Dimensional Gadolinium-Enhanced MR Angiography in the Assessment of Extracranial Carotid Artery Disease Am. J. Roentgenol., August 1, 2000; 175(2): 455 - 463. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Visser and M. G. Myriam Hunink Peripheral Arterial Disease: Gadolinium-enhanced MR Angiography versus Color-guided Duplex US-A Meta-analysis Radiology, July 1, 2000; 216(1): 67 - 77. [Abstract] [Full Text] |
||||
![]() |
D. Weishaupt, S. G. Ruhm, C. A. Binkert, M. Schmidt, M. A. Patak, F. Steybe, S. McGill, and J. F. Debatin Equilibrium-Phase MR Angiography of the Aortoiliac and Renal Arteries Using a Blood Pool Contrast Agent Am. J. Roentgenol., July 1, 2000; 175(1): 189 - 195. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Ruehm, T. F. Hany, T. Pfammatter, E. Schneider, M. Ladd, and J. F. Debatin Pelvic and Lower Extremity Arterial Imaging: Diagnostic Performance of Three-Dimensional Contrast-Enhanced MR Angiography Am. J. Roentgenol., April 1, 2000; 174(4): 1127 - 1135. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Clarke, H.-J. Weinmann, E. Dai, A. R. Lucas, and B. K. Rutt Comparison of Two Blood Pool Contrast Agents for 0.5-T MR Angiography: Experimental Study in Rabbits Radiology, March 1, 2000; 214(3): 787 - 794. [Abstract] [Full Text] |
||||
![]() |
N. M. Rofsky and M. A. Adelman MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease Radiology, February 1, 2000; 214(2): 325 - 338. [Abstract] [Full Text] |
||||
![]() |
E. Sueyoshi, I. Sakamoto, Y. Matsuoka, Y. Ogawa, H. Hayashi, R. Hashmi, and K. Hayashi Aortoiliac and Lower Extremity Arteries: Comparison of Three-dimensional Dynamic Contrast-enhanced Subtraction MR Angiography and Conventional Angiography Radiology, March 1, 1999; 210(3): 683 - 688. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |