Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buckley, J. A.
Right arrow Articles by Fishman, E. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buckley, J. A.
Right arrow Articles by Fishman, E. K.

Radiology, Vol 196, 395-400, Copyright © 1995 by Radiological Society of North America


ARTICLES

Pulmonary nodules: effect of increased data sampling on detection with spiral CT and confidence in diagnosis

JA Buckley, WW Scott Jr, SS Siegelman, JE Kuhlman, BA Urban, DA Bluemke and EK Fishman
Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Hospital, Baltimore, MD 21287, USA.

PURPOSE: To compare spiral computed tomography (CT) with interscan spacing of 4-5 mm versus 8-10 mm for detection rate and level of confidence in diagnosis of pulmonary nodules. MATERIALS AND METHODS: Four radiologists (two junior and two senior faculty members) retrospectively reviewed 67 spiral CT studies with one to six nodules per study. Every second image was masked, which resulted in 8-mm sections every 8 or 10 mm; then all images reconstructed every 4 or 5 mm were reviewed. Lesions were classified as definite, probable, or possible. RESULTS: Narrow interscan spacing yielded more lesions overall (583 vs 566, P < .025) and more definite lesions and fewer equivocal lesions (482 vs 431 and 101 vs 135, respectively; P < .055). The greatest effects were in the reduction of possible lesions (50 vs 88, P < .001) and in the reduction of false-positive diagnoses made by less experienced radiologists. CONCLUSION: Increased reconstruction frequency of spiral CT volume data sets improves detection of pulmonary nodules and enhances confidence in the diagnosis.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. K. Leader, T. E. Warfel, C. R. Fuhrman, S. K. Golla, J. L. Weissfeld, R. S. Avila, W. D. Turner, and B. Zheng
Pulmonary Nodule Detection with Low-Dose CT of the Lung: Agreement Among Radiologists
Am. J. Roentgenol., October 1, 2005; 185(4): 973 - 978.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J.-S. Kim, J.-H. Kim, G. Cho, and K. T. Bae
Automated Detection of Pulmonary Nodules on CT Images: Effect of Section Thickness and Reconstruction Interval--Initial Results
Radiology, July 1, 2005; 236(1): 295 - 299.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. M. Hansell
Small-Vessel Diseases of the Lung: CT-Pathologic Correlates
Radiology, December 1, 2002; 225(3): 639 - 653.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. F. Gruden, S. Ouanounou, S. Tigges, S. D. Norris, and T. S. Klausner
Incremental Benefit of Maximum-Intensity-Projection Images on Observer Detection of Small Pulmonary Nodules Revealed by Multidetector CT
Am. J. Roentgenol., July 1, 2002; 179(1): 149 - 157.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
V. Ambrogi, M. Paci, E. Pompeo, and T. C. Mineo
Transxiphoid video-assisted pulmonary metastasectomy: relevance of helical computed tomography occult lesions
Ann. Thorac. Surg., December 1, 2000; 70(6): 1847 - 1852.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Itoh, M. Ikeda, S. Arahata, T. Kodaira, T. Isomura, T. Kato, K. Yamakawa, K. Maruyama, and T. Ishigaki
Lung Cancer Screening: Minimum Tube Current Required for Helical CT
Radiology, April 1, 2000; 215(1): 175 - 183.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
P. Haage, T. Schmitz-Rode, D. Hubner, W. Piroth, and R. W. Gunther
Reduction of Contrast Material Dose and Artifacts by a Saline Flush Using a Double Power Injector in Helical CT of the Thorax
Am. J. Roentgenol., April 1, 2000; 174(4): 1049 - 1053.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Kakinuma, H. Ohmatsu, M. Kaneko, K. Eguchi, T. Naruke, K. Nagai, Y. Nishiwaki, A. Suzuki, and N. Moriyama
Detection Failures in Spiral CT Screening for Lung Cancer: Analysis of CT Findings
Radiology, June 1, 1999; 212(1): 61 - 66.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.