Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boone, J. M.
Right arrow Articles by Moore, E. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boone, J. M.
Right arrow Articles by Moore, E. H.

Radiology, Vol 196, 845-850, Copyright © 1995 by Radiological Society of North America


ARTICLES

Filter wheel equalization in chest radiography: demonstration with a prototype system

JM Boone, J Duryea and EH Moore
Department of Radiology, University of California, Davis 95817, USA.

PURPOSE: To determine the feasibility of using the filter wheel equalization (FWE) technique for radiographic equalization in chest radiography. MATERIALS AND METHODS: An FWE system with two rotating wheels (one for each lung) with 25 lung-shaped, 1.0-mm-thick copper templates was constructed. Preexposure images were acquired; the computer used these images to select and position templates for each lung. An equalized radiograph was then produced. Radiographs were acquired in two male volunteers (both 33 years of age) and in a phantom. RESULTS: Optical densities in the lungs and nonlung areas on a conventional phantom radiograph were 2.07 and 0.55, respectively; after equalization, the corresponding optical densities were 2.06 and 1.42. Outside the lungs, radiographic contrast (difference in optical density) increased threefold; in the lungs, there was a very small decrease in radiographic contrast due to beam hardening. Well-equalized and relatively artifact-free radiographs were obtained with a 20-msec exposure time. CONCLUSION: The FWE system was shown in the laboratory to be feasible.


This article has been cited by other articles:


Home page
RadiologyHome page
S. Molloi, A. Van Drie, and F. Wang
X-ray Beam Equalization: Feasibility and Performance of an Automated Prototype System in a Phantom and Swine
Radiology, December 1, 2001; 221(3): 668 - 675.