Radiology, Vol 197, 175-181, Copyright © 1995 by Radiological Society of North America
ARTICLES |
SG Silverman, BD Collick, MR Figueira, R Khorasani, DF Adams, RW Newman, GP Topulos and FA Jolesz
Department of Radiology, Brigham and Women's Hospital, Boston, MA 02115, USA.
PURPOSE: To describe new techniques for percutaneous biopsy with use of an open-configuration magnetic resonance (MR) imaging system with integrated frameless stereotaxic guidance tools. MATERIALS AND METHODS: In 28 patients, biopsy was performed in which the image plane was interactively controlled by the position of a hand-held probe attached to the biopsy needle. An icon integrated into the image was used to guide needle advancement in three planes orthogonal to the needle. In vitro measurements of spatial accuracy were also performed. RESULTS: Diagnostic tissue was retrieved in 25 of 28 patients. The system was most accurate near the isocenter with a maximum measured error of 3.1 mm within a sphere of radius 2.5 cm about the isocenter. CONCLUSION: MR- guided biopsy with a frameless stereotaxic technique is safe and accurate. Image feedback is near real time, and the procedure is interactive. These techniques may be used to perform MR-guided biopsies and to place probes for MR-guided therapies.
This article has been cited by other articles:
![]() |
J. S. Lewin, S. G. Nour, M. L. Meyers, A. K. Metzger, R. J. Maciunas, M. Wendt, J. L. Duerk, A. Oppelt, and W. R. Selman Intraoperative MRI with a Rotating, Tiltable Surgical Table: A Time Use Study and Clinical Results in 122 Patients Am. J. Roentgenol., November 1, 2007; 189(5): 1096 - 1103. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Carrino, B. Khurana, J. E. Ready, S. G. Silverman, and C. S. Winalski Magnetic Resonance Imaging-Guided Percutaneous Biopsy of Musculoskeletal Lesions J. Bone Joint Surg. Am., October 1, 2007; 89(10): 2179 - 2187. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Tuncali, P. R. Morrison, C. S. Winalski, J. A. Carrino, S. Shankar, J. E. Ready, E. vanSonnenberg, and S. G. Silverman MRI-Guided Percutaneous Cryotherapy for Soft-Tissue and Bone Metastases: Initial Experience Am. J. Roentgenol., July 1, 2007; 189(1): 232 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Silverman, Y. U. Gan, K. J. Mortele, K. Tuncali, and E. S. Cibas Renal Masses in the Adult Patient: The Role of Percutaneous Biopsy Radiology, July 1, 2006; 240(1): 6 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. K. Wacker, S. Vogt, A. Khamene, J. A. Jesberger, S. G. Nour, D. R. Elgort, F. Sauer, J. L. Duerk, and J. S. Lewin An Augmented Reality System for MR Image-guided Needle Biopsy: Initial Results in a Swine Model Radiology, February 1, 2006; 238(2): 497 - 504. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Silverman, K. Tuncali, E. vanSonnenberg, P. R. Morrison, S. Shankar, N. Ramaiya, and J. P. Richie Renal Tumors: MR Imaging-guided Percutaneous Cryotherapy--Initial Experience in 23 Patients Radiology, August 1, 2005; 236(2): 716 - 724. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. N. Goldberg, C. J. Grassi, J. F. Cardella, J. W. Charboneau, G. D. Dodd II, D. E. Dupuy, D. Gervais, A. R. Gillams, R. A. Kane, F. T. Lee Jr, et al. Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria Radiology, June 1, 2005; 235(3): 728 - 739. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. N. Goldberg, J. W. Charboneau, G. D. Dodd III, D. E. Dupuy, D. A. Gervais, A. R. Gillams, R. A. Kane, F. T. Lee Jr, T. Livraghi, J. P. McGahan, et al. Image-guided Tumor Ablation: Proposal for Standardization of Terms and Reporting Criteria Radiology, August 1, 2003; 228(2): 335 - 345. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Rybicki, K. M. Shu, E. S. Cibas, J. R. Fielding, E. vanSonnenberg, and S. G. Silverman Percutaneous Biopsy of Renal Masses: Sensitivity and Negative Predictive Value Stratified by Clinical Setting and Size of Masses Am. J. Roentgenol., May 1, 2003; 180(5): 1281 - 1287. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Aschoff, E. M. Merkle, S. N. Emancipator, C. A. Petersilge, J. L. Duerk, and J. S. Lewin Femur: MR Imaging-guided Radio-frequency Ablation in a Porcine Model— Feasibility Study Radiology, November 1, 2002; 225(2): 471 - 478. [Abstract] [Full Text] [PDF] |
||||
![]() |
E A Dick, S D Taylor-Robinson, H C Thomas, and W M W Gedroyc Ablative therapy for liver tumours Gut, May 1, 2002; 50(5): 733 - 739. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. S. Winalski, M. I. Robbins, S. G. Silverman, and J. A.K. Davies Interactive Magnetic Resonance Image-Guided Aspiration Therapy of a Glenoid Labral Cyst : A Case Report J. Bone Joint Surg. Am., August 1, 2001; 83(8): 1237 - 1242. [Full Text] |
||||
![]() |
E. Salomonowitz MR Imaging-Guided Biopsy and Therapeutic Intervention in a Closed-Configuration Magnet: Single-Center Series of 361 Punctures Am. J. Roentgenol., July 1, 2001; 177(1): 159 - 163. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Hata, M. Jinzaki, D. Kacher, R. Cormak, D. Gering, A. Nabavi, S. G. Silverman, A. V. D'Amico, R. Kikinis, F. A. Jolesz, et al. MR Imaging-guided Prostate Biopsy with Surgical Navigation Software: Device Validation and Feasibility Radiology, July 1, 2001; 220(1): 263 - 268. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Martin, H. Liu, W. A. Hall, and C. L. Truwit Preliminary Assessment of Turbo Spectroscopic Imaging for Targeting in Brain Biopsy AJNR Am. J. Neuroradiol., May 1, 2001; 22(5): 959 - 968. [Abstract] [Full Text] |
||||
![]() |
C. M. C. Tempany and B. J. McNeil Advances in Biomedical Imaging JAMA, February 7, 2001; 285(5): 562 - 567. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Silverman, K. Tuncali, D. F. Adams, E. vanSonnenberg, K. H. Zou, D. F. Kacher, P. R. Morrison, and F. A. Jolesz MR Imaging-guided Percutaneous Cryotherapy of Liver Tumors: Initial Experience Radiology, December 1, 2000; 217(3): 657 - 664. [Abstract] [Full Text] |
||||
![]() |
P. L. Pereira, I. Gunaydin, J. Trubenbach, F. Dammann, C. T. Remy, I. Kotter, F. Schick, C. W. Koenig, and C. D. Claussen Interventional MR Imaging for Injection of Sacroiliac Joints in Patients with Sacroiliitis Am. J. Roentgenol., July 1, 2000; 175(1): 265 - 266. [Full Text] [PDF] |
||||
![]() |
J. Lewin Interventional MR Imaging: Concepts, Systems, and Applications in AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 735 - 748. [Full Text] |
||||
![]() |
J. S. Lewin, E. M. Merkle, J. L. Duerk, and R. W. Tarr Low-Flow Vascular Malformations in the Head and Neck: Safety and Feasibility of MR Imaging–guided Percutaneous Sclerotherapy—Preliminary Experience with 14 Procedures in Three Patients Radiology, May 1, 1999; 211(2): 566 - 570. [Abstract] [Full Text] |
||||
![]() |
J. W. Genant, J. E. Vandevenne, A. G. Bergman, C. F. Beaulieu, S. T. Kee, A. M. Norbash, and P. Lang Interventional Musculoskeletal Procedures Performed by Using MR Imaging Guidance with a Vertically Open MR Unit: Assessment of Techniques and Applicability Radiology, April 1, 2002; 223(1): 127 - 136. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |