Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rubin, J. M.
Right arrow Articles by Carson, P. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rubin, J. M.
Right arrow Articles by Carson, P. L.

Radiology, Vol 197, 183-190, Copyright © 1995 by Radiological Society of North America


ARTICLES

Fractional moving blood volume: estimation with power Doppler US

JM Rubin, RS Adler, JB Fowlkes, S Spratt, JE Pallister, JF Chen and PL Carson
Department of Radiology, University of Michigan, Ann Arbor 48109, USA.

PURPOSE: To estimate the fraction of moving blood in tissue with power Doppler ultrasound (US). MATERIALS AND METHODS: Power Doppler US measurements of moving scatterers in a flow tube were made as a function of successive dilutions of the perfusate. Measurements were normalized relative to the maximum Doppler power in the center of the flow tube at the highest concentration and were used to calculate the fractional dilution of the perfusate for each run with each dilution used to represent increasing amounts of non-moving soft tissue in the sample volume. The technique was also applied to two clinical examples. RESULTS: Successive dilutions of the perfusate in the flow experiment showed a monotonic, linear decrease in the Doppler power as a function of dilution. CONCLUSION: The power Doppler US technique has the potential to more accurately estimate alterations in blood flow and has the advantage of being a continuous parameter that can be depth normalized.


This article has been cited by other articles:


Home page
Ann Rheum DisHome page
S. A Wright, E. Filippucci, C. McVeigh, A. Grey, M. McCarron, W. Grassi, G. D Wright, and A. J Taggart
High-resolution ultrasonography of the first metatarsal phalangeal joint in gout: a controlled study
Ann Rheum Dis, July 1, 2007; 66(7): 859 - 864.
[Abstract] [Full Text] [PDF]


Home page
Cancer Res.Home page
J. W. Xuan, M. Bygrave, H. Jiang, F. Valiyeva, J. Dunmore-Buyze, D. W. Holdsworth, J. I. Izawa, G. Bauman, M. Moussa, S. F. Winter, et al.
Functional Neoangiogenesis Imaging of Genetically Engineered Mouse Prostate Cancer Using Three-Dimensional Power Doppler Ultrasound
Cancer Res., March 15, 2007; 67(6): 2830 - 2839.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
E Filippucci, A Iagnocco, F Salaffi, A Cerioni, G Valesini, and W Grassi
Power Doppler sonography monitoring of synovial perfusion at the wrist joints in patients with rheumatoid arthritis treated with adalimumab
Ann Rheum Dis, November 1, 2006; 65(11): 1433 - 1437.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
O. D. Kripfgans, J. M. Rubin, A. L. Hall, M. B. Gordon, and J. B. Fowlkes
Measurement of volumetric flow.
J. Ultrasound Med., October 1, 2006; 25(10): 1305 - 1311.
[Abstract] [Full Text] [PDF]


Home page
LupusHome page
S Wright, E Filippucci, W Grassi, A Grey, and A Bell
Hand Arthritis in Systemic Lupus Erythematosus: An Ultrasound Pictorial Essay
Lupus, August 1, 2006; 15(8): 501 - 506.
[Abstract] [PDF]


Home page
Rheumatology (Oxford)Home page
J. Strunk, K. Strube, P. Klingenberger, U. Muller-Ladner, and U. Lange
Two- and three-dimensional Doppler sonographic evaluation of the effect of local cryotherapy on synovial perfusion in wrist arthritis
Rheumatology, May 1, 2006; 45(5): 637 - 640.
[Full Text] [PDF]


Home page
J Ultrasound MedHome page
F. Forsberg, J.-B. Liu, W. T. Shi, R. Ro, K. J. Lipcan, X. Deng, and A. L. Hall
In vivo perfusion estimation using subharmonic contrast microbubble signals.
J. Ultrasound Med., January 1, 2006; 25(1): 15 - 21.
[Abstract] [Full Text] [PDF]


Home page
Rheumatology (Oxford)Home page
P. C. Taylor
Serum vascular markers and vascular imaging in assessment of rheumatoid arthritis disease activity and response to therapy
Rheumatology, June 1, 2005; 44(6): 721 - 728.
[Abstract] [Full Text] [PDF]


Home page
Rheumatology (Oxford)Home page
J. Strunk, E. Heinemann, G. Neeck, K. L. Schmidt, and U. Lange
A new approach to studying angiogenesis in rheumatoid arthritis by means of power Doppler ultrasonography and measurement of serum vascular endothelial growth factor
Rheumatology, December 1, 2004; 43(12): 1480 - 1483.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
L Terslev, S Torp-Pedersen, E Qvistgaard, P von der Recke, and H Bliddal
Doppler ultrasound findings in healthy wrists and finger joints
Ann Rheum Dis, June 1, 2004; 63(6): 644 - 648.
[Abstract] [Full Text]


Home page
Ann Rheum DisHome page
E Filippucci, A Farina, M Carotti, F Salaffi, and W Grassi
Grey scale and power Doppler sonographic changes induced by intra-articular steroid injection treatment
Ann Rheum Dis, June 1, 2004; 63(6): 740 - 743.
[Abstract] [Full Text]


Home page
J Ultrasound MedHome page
A. C. Fleischer, E. F. Donnelly, R. J. Grippo, A. S. Black, and D. E. Hallahan
Quantification of Tumor Vascularity With Contrast-Enhanced Sonography: Correlation With Magnetic Resonance Imaging and Fluorodeoxyglucose Autoradiography in an Implanted Tumor
J. Ultrasound Med., January 1, 2004; 23(1): 37 - 41.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H-D Liang and M J K Blomley
The role of ultrasound in molecular imaging
Br. J. Radiol., December 1, 2003; 76(suppl_2): S140 - S150.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
L Terslev, S Torp-Pedersen, E Qvistgaard, B Danneskiold-Samsoe, and H Bliddal
Estimation of inflammation by Doppler ultrasound: quantitative changes after intra-articular treatment in rheumatoid arthritis
Ann Rheum Dis, November 1, 2003; 62(11): 1049 - 1053.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Walther, H. Harms, V. Krenn, S. Radke, S. Kirschner, and F. Gohlke
Synovial Tissue of the Hip at Power Doppler US: Correlation between Vascularity and Power Doppler US Signal
Radiology, October 1, 2002; 225(1): 225 - 231.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
E. R Mohler III, C. M Sehgal, V. A Ferrari, M. Parmacek, A. Shih, and R. L Wilensky
A novel ultrasound method for evaluation of collateral development in limb ischemia
Vascular Medicine, August 1, 2002; 7(3): 169 - 175.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
E. J. Halpern, F. Frauscher, M. Rosenberg, and L. G. Gomella
Directed Biopsy During Contrast-Enhanced Sonography of the Prostate
Am. J. Roentgenol., April 1, 2002; 178(4): 915 - 919.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Claudon, D. Winninger, S. Briançon, and P. Pesque
Power Doppler US: Evaluation of the Morphology of Stenoses with a Flow Phantom
Radiology, January 1, 2001; 218(1): 109 - 117.
[Abstract] [Full Text]


Home page
Vasc MedHome page
E. R Mohler III, B. Klugherz, R. Goldman, S. E Kimmel, M. Wade, and C. M Sehgal
Trial of a novel prostacyclin analog, UT-15, in patients with severe intermittent claudication
Vascular Medicine, November 1, 2000; 5(4): 231 - 237.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
T. S. Keener, T. C. Winter, R. Berger, J. N. Krieger, C. Nodell, I. Rothman, and H. V. Nghiem
Prostate Vascular Flow: The Effect of Ejaculation as Revealed on Transrectal Power Doppler Sonography
Am. J. Roentgenol., October 1, 2000; 175(4): 1169 - 1172.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
G. Seidel, C. Algermissen, A. Christoph, T. Katzer, M. Kaps, and R. W. Baumgartner
Visualization of Brain Perfusion With Harmonic Gray Scale and Power Doppler Technology : An Animal Pilot Study Editorial Comment: An Animal Pilot Study
Stroke, July 1, 2000; 31(7): 1728 - 1734.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Rubin, J. B. Fowlkes, T. A. Tuthill, A. P. Moskalik, R. T. Rhee, R. S. Adler, S. N. Kazanjian, and P. L. Carson
Speckle Decorrelation Flow Measurement with B-Mode US of Contrast Agent Flow in a Phantom and in Rabbit Kidney
Radiology, November 1, 1999; 213(2): 429 - 437.
[Abstract] [Full Text]


Home page
Journal of Diagnostic Medical SonographyHome page
T. Y. Cheng, T. Janik, and R. B. Meacham
Construction of a Flow Phantom for Use in Color Power Sonography
Journal of Diagnostic Medical Sonography, January 1, 1999; 15(1): 23 - 25.
[Abstract] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
G. S. Lin, D. T. Milburn, and S. Briggs
Power Doppler: How It Works, Its Clinical Benefits, and Recent Technologic Advances
Journal of Diagnostic Medical Sonography, July 1, 1998; 14(4): 151 - 161.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.