Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liu, B.
Right arrow Articles by Chan, H. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liu, B.
Right arrow Articles by Chan, H. P.

Radiology, Vol 197, 27-32, Copyright © 1995 by Radiological Society of North America


ARTICLES

Normalized average glandular dose in magnification mammography

B Liu, M Goodsitt and HP Chan
Department of Radiology, University of Michigan, Ann Arbor 48105, USA.

PURPOSE: To evaluate the normalized average glandular dose (the average glandular dose per unit entrance skin exposure) in magnification mammography. MATERIALS AND METHODS: Photon transport in the breast was simulated by using Monte Carlo methods. A semielliptical cylinder containing glandular and adipose tissue was used to simulate the breast. Measured mammography spectra for a molybdenum target-molybdenum filter unit were utilized. The normalized average glandular dose was calculated as a function of half-value layer, tube voltage, breast thickness, and breast composition for typical magnification geometries. RESULTS: The normalized average glandular dose in magnification mammography is 7%-25% lower than that with the contact (nonmagnification) technique because of the effects of partial irradiation, smaller field size, and greater percentage depth dose gradient at the reduced source-to-skin distance. CONCLUSION: The normalized average glandular dose in magnification mammography is lower than that in contact mammography. The average glandular dose in magnification mammography, however, is still substantially greater due to the two to three times greater entrance skin exposure.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
S Obenauer, K-P Hermann, and E Grabbe
Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study
Br. J. Radiol., July 1, 2003; 76(907): 478 - 482.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. L. Fricke, L. F. Donnelly, D. P. Frush, T. Yoshizumi, V. Varchena, S. A. Poe, and J. Lucaya
In-Plane Bismuth Breast Shields for Pediatric CT: Effects on Radiation Dose and Image Quality Using Experimental and Clinical Data
Am. J. Roentgenol., February 1, 2003; 180(2): 407 - 411.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Kimme-Smith
New Digital Mammography Systems May Require Different X-ray Spectra and, Therefore, More General Normalized Glandular Dose Values
Radiology, October 1, 1999; 213(1): 7 - 10.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.