Radiology, Vol 197, 73-78, Copyright © 1995 by Radiological Society of North America
ARTICLES |
SE Seltzer, PF Judy, DF Adams, FL Jacobson, P Stark, R Kikinis, RG Swensson, S Hooton, B Head and U Feldman
Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, Boston, MA 02115, USA.
PURPOSE: To determine radiologists' ability to find lung nodules on spiral computed tomographic (CT) scans of the chest with both rapid sequential (cine) and conventional film-based viewing. MATERIALS AND METHODS: Eight radiologists searched for lung nodules on spiral CT images (10-mm collimation, 10 mm/sec table speed) presented in two formats. Cine viewing was performed at a computer work-station; sections were viewed in 2-mm increments at frame rates up to 10 frames per second. Film-based viewing of images from a laser printer was performed with a lightbox; sections were viewed at 4-mm increments. Eight 3-5-mm-diameter simulated nodules were superimposed on each of five normal CT scans. RESULTS: Radiologists found a higher fraction of nodules with the cine presentation than with film (mean, 0.69 +/- 0.02 [standard error] versus 0.58 +/- 0.03, respectively [P = .006]). Diameter thresholds for nodule detection (50% correctly localized) were 3.3 and 3.5 mm, respectively. CONCLUSION: Cine viewing of spiral CT images of the chest improved radiologists' ability to detect nodules.
This article has been cited by other articles:
![]() |
P. Peloschek, J. Sailer, M. Weber, C. J. Herold, M. Prokop, and C. Schaefer-Prokop Pulmonary Nodules: Sensitivity of Maximum Intensity Projection versus That of Volume Rendering of 3D Multidetector CT Data Radiology, May 1, 2007; 243(2): 561 - 569. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Wittram How I Do It: CT Pulmonary Angiography Am. J. Roentgenol., May 1, 2007; 188(5): 1255 - 1261. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Li, H. Arimura, K. Suzuki, J. Shiraishi, Q. Li, H. Abe, R. Engelmann, S. Sone, H. MacMahon, and K. Doi Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization Radiology, November 1, 2005; 237(2): 684 - 690. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. J. Kim, J. K. Han, S. H. Kim, J. Y. Jeong, S. K. An, C. J. Han, K.-R. Son, K. H. Lee, J. M. Lee, and B. I. Choi Small-Bowel Obstruction in a Phantom Model of ex Vivo Porcine Intestine: Comparison of PACS Stack and Tile Modes for CT Interpretation Radiology, September 1, 2005; 236(3): 867 - 871. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Johnson Hard- versus Soft-Copy Interpretation Radiology, June 1, 2003; 227(3): 629 - 630. [Full Text] [PDF] |
||||
![]() |
M. E. J. Pijl, M. N. J. M. Wasser, E. C. Joekes, C. J. H. van de Velde, and J. L. Bloem Metastases of Colorectal Carcinoma: Comparison of Soft- and Hard-Copy Helical CT Interpretation Radiology, June 1, 2003; 227(3): 747 - 751. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, Y. Mori, K. Suzuki, A. Sawaki, S. Iwano, H. Satake, S. Arahata, T. Isomura, M. Ozaki, et al. Lung: Feasibility of a Method for Changing Tube Current during Low-Dose Helical CT Radiology, September 1, 2002; 224(3): 905 - 912. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Gruden, S. Ouanounou, S. Tigges, S. D. Norris, and T. S. Klausner Incremental Benefit of Maximum-Intensity-Projection Images on Observer Detection of Small Pulmonary Nodules Revealed by Multidetector CT Am. J. Roentgenol., July 1, 2002; 179(1): 149 - 157. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Hirsch, W. A. Franklin, A. F. Gazdar, and P. A. Bunn Jr. Early Detection of Lung Cancer: Clinical Perspectives of Recent Advances in Biology and Radiology Clin. Cancer Res., January 1, 2001; 7(1): 5 - 22. [Abstract] [Full Text] |
||||
![]() |
P. M. Boiselle, A. Ernst, and D. D. Karp Lung Cancer Detection in the 21st Century: Potential Contributions and Challenges of Emerging Technologies Am. J. Roentgenol., November 1, 2000; 175(5): 1215 - 1221. [Full Text] [PDF] |
||||
![]() |
S. Itoh, M. Ikeda, S. Arahata, T. Kodaira, T. Isomura, T. Kato, K. Yamakawa, K. Maruyama, and T. Ishigaki Lung Cancer Screening: Minimum Tube Current Required for Helical CT Radiology, April 1, 2000; 215(1): 175 - 183. [Abstract] [Full Text] |
||||
![]() |
C. Karadi, C. F. Beaulieu, R. B. Jeffrey Jr, D. S. Paik, and S. Napel Display Modes for CT Colonography: Part I. Synthesis and Insertion of Polyps into Patient CT Data Radiology, July 1, 1999; 212(1): 195 - 201. [Abstract] [Full Text] |
||||
![]() |
C. F. Beaulieu, R. B. Jeffrey Jr, C. Karadi, D. S. Paik, and S. Napel Display Modes for CT Colonography: Part II. Blinded Comparison of Axial CT and Virtual Endoscopic and Panoramic Endoscopic Volume-rendered Studies Radiology, July 1, 1999; 212(1): 203 - 212. [Abstract] [Full Text] |
||||
![]() |
R. Kakinuma, H. Ohmatsu, M. Kaneko, K. Eguchi, T. Naruke, K. Nagai, Y. Nishiwaki, A. Suzuki, and N. Moriyama Detection Failures in Spiral CT Screening for Lung Cancer: Analysis of CT Findings Radiology, June 1, 1999; 212(1): 61 - 66. [Abstract] [Full Text] |
||||
![]() |
F. E. IV, J. H. Ryu, G. M. Miller, P. H. Luetmer, L. A. Forstrom, O. L. Burnett, C. M. Rowland, S. J. Swensen, and D. E. Midthun Suspected Non–Small Cell Lung Cancer: Incidence of Occult Brain and Skeletal Metastases and Effectiveness of Imaging for Detection—Pilot Study Radiology, April 1, 1999; 211(1): 137 - 145. [Abstract] [Full Text] |
||||
![]() |
R. Ammar, E. Porat, D. S. Eisenberg, and G. Uretzky Utility of spiral CT in minimally invasive approach for aortic valve replacement Eur. J. Cardiothorac. Surg., October 1, 1998; 14(suppl_1): S130 - S133. [Abstract] [Full Text] [PDF] |
||||