Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kicken, P. J.
Right arrow Articles by Bos, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kicken, P. J.
Right arrow Articles by Bos, A. J.

Radiology, Vol 197, 473-478, Copyright © 1995 by Radiological Society of North America


ARTICLES

Effectiveness of lead aprons in vascular radiology: results of clinical measurements

PJ Kicken and AJ Bos
Department of Radiology, University Hospital Maastricht, The Netherlands.

PURPOSE: To determine the effectiveness of 0.5-mm-thick lead-equivalent aprons in vascular radiology. MATERIALS AND METHODS: The radiation dose to radiology personnel was measured under and over lead aprons in more than 100 patient examinations. Thermoluminescent dosimeters of high and normal sensitivities (detection levels of 1 and 10 microGy, respectively) were used. Dose measurements in clinical practice were complemented with real-time measurement of generating potential, dose- area product, and fluoroscopy time. In addition, measurements of the radiation attenuation of aprons were performed in simulated exposure conditions. The generating potential in fluoroscopy--weighted for the contribution to the occupational exposure--varied between about 70 and 95 kV per examination (average, 78 kV). RESULTS: On the basis of measurements obtained under clinical conditions in vascular radiology, attenuation factors between 70 and 280 were derived. The typical radiation attenuation factor for 0.5-mm-thick lead-equivalent aprons was 200. CONCLUSION: The effectiveness of 0.5-mm-thick lead-equivalent aprons, determined with clinical measurements, agrees with estimates based on generating potential. Previously published effective doses, inferred from nonclinically determined radiation transmission factors, probably overestimate the actual dose levels.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
F. W. Schultz and J. Zoetelief
Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters
Radiat Prot Dosimetry, May 1, 2006; 118(2): 196 - 204.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
F W Schultz, J Geleijns, F M Spoelstra, and J Zoetelief
Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations
Br. J. Radiol., September 1, 2003; 76(909): 638 - 647.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.