Radiology, Vol 197, 627-633, Copyright © 1995 by Radiological Society of North America
ARTICLES |
VS Lee, RH Wilkinson Jr, GS Leight Jr, AC Coogan and RE Coleman
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA.
PURPOSE: To evaluate the accuracy of technetium-99m sestamibi as a single agent in the detection and localization of hyperfunctioning parathyroid tissue in patients who underwent prior neck exploration or who otherwise are high surgical risks. MATERIALS AND METHODS: Thirty- nine patients with hyperparathyroidism underwent 40 double-phase Tc-99m sestamibi studies. Histopathologic correlation was obtained for all studies. RESULTS: Thirty patients had solitary adenomas, and nine had hyperplastic glands. One developed recurrent hypercalcemia after five- gland resection and underwent repeat imaging and operation. Double- phase sestamibi imaging prospectively enabled localization of 46 (77%) of 60 abnormal glands. Twenty-eight (93%) of 30 adenomas were correctly localized, whereas 18 (60%) of 30 hyperplastic glands were localized. The overall specificity of the study was 98% with one false-positive study. Gland weight and vascularity were statistically significant predictors of uptake of sestamibi. CONCLUSION: Double-phase Tc-99m sestamibi imaging is a promising technique for localization of parathyroid adenomas in high-risk surgical patients. Localization of multiple hyperplastic glands remains a challenge.
This article has been cited by other articles:
![]() |
J. Kollars, A. E. Zarroug, J. van Heerden, A. Lteif, P. Stavlo, L. Suarez, C. Moir, M. Ishitani, and D. Rodeberg Primary Hyperparathyroidism in Pediatric Patients Pediatrics, April 1, 2005; 115(4): 974 - 980. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. P. Purcell, F. M. Dirbas, R. B. Jeffrey, M. J. Lane, T. Desser, I. R. McDougall, and R. J. Weigel Parathyroid Localization With High-Resolution Ultrasound and Technetium Tc 99m Sestamibi Arch Surg, August 1, 1999; 134(8): 824 - 830. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. D. Nguyen Parathyroid Imaging with Tc-99m Sestamibi Planar and SPECT Scintigraphy RadioGraphics, May 1, 1999; 19(3): 601 - 614. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Neumann, C. B. Esselstyn Jr., A. Madera, C. O. Wong, and M. Lieber Parathyroid Detection in Secondary Hyperparathyroidism with 123I/99mTc-Sestamibi Subtraction Single Photon Emission Computed Tomography J. Clin. Endocrinol. Metab., November 1, 1998; 83(11): 3867 - 3871. [Abstract] [Full Text] |
||||
![]() |
R. A. Sofferman and M. H. Nathan The Ectopic Parathyroid Adenoma: A Cost Justification for Routine Preoperative Localization With Technetium Tc 99m Sestamibi Scan Arch Otolaryngol Head Neck Surg, June 1, 1998; 124(6): 649 - 654. [Abstract] [Full Text] [PDF] |
||||