Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gupta, H.
Right arrow Articles by Weissleder, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gupta, H.
Right arrow Articles by Weissleder, R.

Radiology, Vol 197, 665-669, Copyright © 1995 by Radiological Society of North America


ARTICLES

Inflammation: imaging with methoxy poly(ethylene glycol)-poly-L-lysine- DTPA, a long-circulating graft copolymer

H Gupta, RA Wilkinson, AA Bogdanov Jr, RJ Callahan and R Weissleder
Department of Radiology, Massachusetts General Hospital, Charlestown 02129, USA.

PURPOSE: To test whether a nontargeted, long-circulating, synthetic polymer accumulates in areas of inflammation, with high capillary permeability and increased regional blood flow. MATERIALS AND METHODS: Methoxy poly(ethylene glycol)-poly-L-lysine (PL)- diethylenetriaminepentaacetic acid (MPEG-PL-DTPA) was labeled with technetium-99m for scintigraphy and with gadolinium for magnetic resonance (MR) imaging. Eleven Escherichia coli-infected rats were injected with 1.0 mCi (37 MBq) of Tc-99m-labeled MPEG-PL-DTPA for scintigraphy. Twelve rats underwent 1.5-T MR imaging after intravenous injection of gadolinium-labeled MPEG-PL-DTPA (35 mumol/kg). RESULTS: Tc- 99m-labeled MPEG-PL-DTPA demonstrated nearly eight-fold higher accumulation in infected muscle when compared with normal muscle. Scintigrams and MR images showed areas of inflammation with peak accumulation at 24 hours after injection of Tc-99m- or gadolinium- labeled MPEG-PL-DTPA. CONCLUSION: Nontargeted, long-circulating, copolymers can efficiently accumulate in sites of inflammation and thus represent an alternative to inflammation-specific agents.


This article has been cited by other articles:


Home page
DiabetesHome page
Z. Medarova, G. Castillo, G. Dai, E. Bolotin, A. Bogdanov, and A. Moore
Noninvasive Magnetic Resonance Imaging of Microvascular Changes in Type 1 Diabetes
Diabetes, November 1, 2007; 56(11): 2677 - 2682.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. K. Moon, K. H. Chang, H.-J. Weinmann, Y. H. Koh, J.-G. Im, K. M. Yeon, and M. C. Han
Dynamic Contrast-Enhanced MR Imaging of Bacterial Abscess and VX2 Carcinoma in Rabbits: Comparison of Gadopentetate Dimeglumine and a Macromolecular Contrast Agent
Am. J. Roentgenol., May 1, 2000; 174(5): 1385 - 1389.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.