Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nath, M. E.
Right arrow Articles by Sumkin, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nath, M. E.
Right arrow Articles by Sumkin, J. H.

Radiology, Vol 197, 739-742, Copyright © 1995 by Radiological Society of North America


ARTICLES

Automated large-core needle biopsy of surgically removed breast lesions: comparison of samples obtained with 14-, 16-, and 18-gauge needles

ME Nath, TM Robinson, H Tobon, DM Chough and JH Sumkin
Department of Pathology, University of Pittsburgh School of Medicine, Pa, USA.

PURPOSE: To determine the needle size that would consistently enable the pathologist to correctly diagnose tissue core biopsy specimens. MATERIALS AND METHODS: Fifty-seven surgically removed mass lesions of the breast were sampled with a short-throw automated biopsy gun and an 18-gauge needle first, followed by a 16- and a 14-gauge needle. Samples were evaluated independently by three pathologists, and findings were compared with the final diagnosis made at surgical excision biopsy. RESULTS: The sensitivity for the diagnosis of all 26 malignant lesions was 100%, 92%, and 65% for biopsy samples obtained with 14-, 16-, and 18-gauge needles, respectively. Specificity for malignancy was 100% for all three needle sizes. All of the benign diseases were correctly diagnosed in samples obtained with all three size needles except for two samples that did not survive processing. CONCLUSION: Biopsy samples obtained with a 14-gauge needle provide the most accurate diagnosis, which correlates with the diagnosis made with the surgical excision biopsy technique.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
M. B. Mainiero, I. F. Gareen, C. E. Bird, W. Smith, C. Cobb, and B. Schepps
Preferential Use of Sonographically Guided Biopsy to Minimize Patient Discomfort and Procedure Time in a Percutaneous Image-Guided Breast Biopsy Program
J. Ultrasound Med., November 1, 2002; 21(11): 1221 - 1226.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild
MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone
Radiology, July 1, 2001; 220(1): 31 - 39.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al.
Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial
Radiology, March 1, 2001; 218(3): 866 - 872.
[Abstract] [Full Text]


Home page
Arch SurgHome page
H. Seoudi, J. Mortier, R. Basile, and E. Curletti
Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique
Arch Surg, April 1, 1998; 133(4): 366 - 372.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.