Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prince, M. R.
Right arrow Articles by Cho, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prince, M. R.
Right arrow Articles by Cho, K. J.

Radiology, Vol 197, 785-792, Copyright © 1995 by Radiological Society of North America


ARTICLES

Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches

MR Prince, DL Narasimham, JC Stanley, TL Chenevert, DM Williams, MV Marx and KJ Cho
Department of Radiology, University of Michigan, Ann Arbor 48109-0030, USA.

PURPOSE: To develop and evaluate a sequence for breath-hold three- dimensional gadolinium-enhanced magnetic resonance (MR) angiography of the abdominal aorta. MATERIALS AND METHODS: In 63 patients, the abdominal aorta and its branches were imaged for 29, 43, or 58 seconds with breath holding. A fast spoiled gradient-echo sequence was used at 1.5 T during infusion of 42 mL of a gadolinium chelate. Correlation with conventional angiography was performed in 19 patients. MR image quality (signal-to-"total" noise ratio [S/N*]) with breath holding was compared with that with free breathing (104 patients). RESULTS: With breath-hold gadolinium-enhanced MR angiography, renal, celiac, and superior mesenteric artery occlusive disease was graded appropriately in 15 of 19 patients, and 10 of 11 accessory renal arteries were depicted correctly. Renal artery branches were visualized in 86 of 95 kidneys on breath-hold images compared with only 84 of 236 kidneys with free breathing (P < .001). Distal renal artery S/N* was 3.1 with breath holding and 2.1 with free breathing (P < .001). CONCLUSION: Breath holding statistically significantly improves three-dimensional gadolinium-enhanced MR angiography of the renal, celiac, and superior mesenteric arteries.


This article has been cited by other articles:


Home page
RadiologyHome page
G. Soulez, M. Pasowicz, G. Benea, L. Grazioli, J. P. Niedmann, M. Konopka, P. C. Douek, G. Morana, F. K. W. Schaefer, A. Vanzulli, et al.
Renal Artery Stenosis Evaluation: Diagnostic Performance of Gadobenate Dimeglumine-enhanced MR Angiography--Comparison with DSA
Radiology, April 1, 2008; 247(1): 273 - 285.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
F. Stepansky, E. M. Hecht, R. Rivera, L. E. Hirsh, B. Taouli, M. Kaur, and V. S. Lee
Dynamic MR Angiography of Upper Extremity Vascular Disease: Pictorial Review
RadioGraphics, January 1, 2008; 28(1): e28 - e28.
[Abstract] [Full Text]


Home page
RadiologyHome page
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh
Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging
Radiology, December 1, 2007; 245(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Wyttenbach, A. Braghetti, M. Wyss, M. Alerci, L. Briner, P. Santini, L. Cozzi, M. Di Valentino, M. Katoh, C. Marone, et al.
Renal Artery Assessment with Nonenhanced Steady-State Free Precession versus Contrast-enhanced MR Angiography
Radiology, October 1, 2007; 245(1): 186 - 195.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. S. Saleh, S. Patel, M. H. Lee, M. I. Boechat, O. Ratib, C. R. Saraiva, and J. P. Finn
Contrast-enhanced MR Angiography of the Chest and Abdomen with Use of Controlled Apnea in Children
Radiology, June 1, 2007; 243(3): 837 - 846.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. M. Groves, W. Bireley, K. Dill, T. J. Carroll, and J. C. Carr
Quantitative Analysis of ECG-Gated High-Resolution Contrast-Enhanced MR Angiography of the Thoracic Aorta
Am. J. Roentgenol., February 1, 2007; 188(2): 522 - 528.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Willoteaux, M. Faivre-Pierret, O. Moranne, C. Lions, J. Bruzzi, M. Finot, V. Gaxotte, C. Mounier-Vehier, and J.-P. Beregi
Fibromuscular Dysplasia of the Main Renal Arteries: Comparison of Contrast-enhanced MR Angiography with Digital Subtraction Angiography
Radiology, December 1, 2006; 241(3): 922 - 929.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Finn, R. Saleh, S. Thesen, S. G. Ruehm, M. H. Lee, J. Grinstead, J. S. Child, and G. Laub
MR Imaging with Remote Control: Feasibility Study in Cardiovascular Disease
Radiology, November 1, 2006; 241(2): 528 - 537.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Nael, H. J. Michaely, U. Kramer, M. H. Lee, J. Goldin, G. Laub, and J. P. Finn
Pulmonary Circulation: Contrast-enhanced 3.0-T MR Angiography--Initial Results
Radiology, September 1, 2006; 240(3): 858 - 868.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Nael, R. Saleh, M. Lee, T. McNamara, S. R. Godinez, G. Laub, J. P. Finn, and S. G. Ruehm
High-spatial-resolution contrast-enhanced MR angiography of abdominal arteries with parallel acquisition at 3.0 T: initial experience in 32 patients.
Am. J. Roentgenol., July 1, 2006; 187(1): W77 - W85.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. W. Huegli, M. Aschwanden, G. Bongartz, K. Jaeger, H.-G. Heidecker, C. Thalhammer, A.-C. Schulte, C. Hashagen, A. L. Jacob, and D. Bilecen
Intraarterial MR Angiography and DSA in Patients with Peripheral Arterial Occlusive Disease: Prospective Comparison
Radiology, June 1, 2006; 239(3): 901 - 908.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Feydy, P. Anract, B. Tomeno, A. Chevrot, and J.-L. Drape
Assessment of Vascular Invasion by Musculoskeletal Tumors of the Limbs: Use of Contrast-enhanced MR Angiography
Radiology, February 1, 2006; 238(2): 611 - 621.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Lapeyre, H. Kobeiter, P. Desgranges, A. Rahmouni, J.-P. Becquemin, and A. Luciani
Assessment of Critical Limb Ischemia in Patients with Diabetes: Comparison of MR Angiography and Digital Subtraction Angiography
Am. J. Roentgenol., December 1, 2005; 185(6): 1641 - 1650.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Sheehy, S. MacNally, C. S. Smith, G. Boyle, P. Madhavan, and J. F. M. Meaney
Contrast-Enhanced MR Angiography of Subclavian Steal Syndrome: Value of the 2D Time-of-Flight "Localizer" Sign
Am. J. Roentgenol., October 1, 2005; 185(4): 1069 - 1073.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Goyen, M. Edelman, P. Perreault, E. O'Riordan, H. Bertoni, J. Taylor, D. Siragusa, M. Sharafuddin, E. R. Mohler III, R. Breger, et al.
MR Angiography of Aortoiliac Occlusive Disease: A Phase III Study of the Safety and Effectiveness of the Blood-Pool Contrast Agent MS-325
Radiology, September 1, 2005; 236(3): 825 - 833.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. P. Sheehy, G. E. Boyle, and J. F. M. Meaney
Normal Anterior Spinal Arteries within the Cervical Region: High-Spatial-Resolution Contrast-enhanced Three-dimensional MR Angiography
Radiology, August 1, 2005; 236(2): 637 - 641.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Prokop, G. Schneider, A. Vanzulli, M. Goyen, S. G. Ruehm, P. Douek, M. Dapra, G. Pirovano, M. A. Kirchin, and A. Spinazzi
Contrast-enhanced MR Angiography of the Renal Arteries: Blinded Multicenter Crossover Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine
Radiology, February 1, 2005; 234(2): 399 - 408.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Vogt, W. Ajaj, P. Hunold, C. U. Herborn, H. H. Quick, J. F. Debatin, and S. G. Ruehm
Venous Compression at High-Spatial-Resolution Three-dimensional MR Angiography of Peripheral Arteries
Radiology, December 1, 2004; 233(3): 913 - 920.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. U. Herborn, M. Goyen, H. H. Quick, S. Bosk, S. Massing, K. Kroeger, D. Stoesser, S. G. Ruehm, and J. F. Debatin
Whole-Body 3D MR Angiography of Patients with Peripheral Arterial Occlusive Disease
Am. J. Roentgenol., June 1, 2004; 182(6): 1427 - 1434.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. W. Olin, J. A. Kaufman, D. A. Bluemke, R. O. Bonow, M. D. Gerhard, M. R. Jaff, G. D. Rubin, and W. Hall
Atherosclerotic Vascular Disease Conference: Writing Group IV: Imaging
Circulation, June 1, 2004; 109(21): 2626 - 2633.
[Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
J. W. Olin and V. Fuster
Acute Aortic Dissection: The Need for Rapid, Accurate, and Readily Available Diagnostic Strategies
Arterioscler. Thromb. Vasc. Biol., October 1, 2003; 23(10): 1721 - 1723.
[Full Text] [PDF]


Home page
RadioGraphicsHome page
K. Yoshioka, H. Niinuma, A. Ohira, K. Nasu, T. Kawakami, M. Sasaki, and K. Kawazoe
MR Angiography and CT Angiography of the Artery of Adamkiewicz: Noninvasive Preoperative Assessment of Thoracoabdominal Aortic Aneurysm
RadioGraphics, September 1, 2003; 23(5): 1215 - 1225.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. T. Bae
Peak Contrast Enhancement in CT and MR Angiography: When Does It Occur and Why? Pharmacokinetic Study in a Porcine Model
Radiology, June 1, 2003; 227(3): 809 - 816.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Goyen, C. U. Herborn, K. Kroger, T. C. Lauenstein, J. F. Debatin, and S. G. Ruehm
Detection of Atherosclerosis: Systemic Imaging for Systemic Disease with Whole-Body Three-dimensional MR Angiography-- Initial Experience
Radiology, April 1, 2003; 227(1): 277 - 282.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. S. Lee, H. Rusinek, M. E. Noz, P. Lee, M. Raghavan, and E. L. Kramer
Dynamic Three-dimensional MR Renography for the Measurement of Single Kidney Function: Initial Experience
Radiology, April 1, 2003; 227(1): 289 - 294.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Wyttenbach, S. Gianella, M. Alerci, A. Braghetti, L. Cozzi, and A. Gallino
Prospective Blinded Evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced Peripheral MR Angiography, as Compared with Digital Subtraction Angiography
Radiology, April 1, 2003; 227(1): 261 - 269.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
N. Wolosker, L. Nakano, G. D'Hippolito, R. A. Rosoky, M. L. Borri, and A. M. B. Wolosker
Gadolinium Magnetic Angioresonance in the Study of Aortoiliac Disease
Angiology, March 1, 2003; 54(2): 163 - 168.
[Abstract] [PDF]


Home page
RadiologyHome page
F. K. Wacker, K. Reither, W. Ebert, M. Wendt, J. S. Lewin, and K.-J. Wolf
MR Image-guided Endovascular Procedures with the Ultrasmall Superparamagnetic Iron Oxide SH U 555 C as an Intravascular Contrast Agent: Study in Pigs
Radiology, February 1, 2003; 226(2): 459 - 464.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. J. Kroencke, M. N. Wasser, P. M. T. Pattynama, J. O. Barentsz, E. Grabbe, G. Marchal, M. V. Knopp, G. Schneider, L. Bonomo, D. J. Pennell, et al.
Gadobenate Dimeglumine--Enhanced MR Angiography of the Abdominal Aorta and Renal Arteries
Am. J. Roentgenol., December 1, 2002; 179(6): 1573 - 1582.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. V. Pandharipande, V. S. Lee, P. M. Reuss, H. W. Charles, R. J. Rosen, G. A. Krinsky, J. C. Weinreb, and N. M. Rofsky
Two-Station Bolus-Chase MR Angiography with a Stationary Table: A Simple Alternative to Automated-Table Techniques
Am. J. Roentgenol., December 1, 2002; 179(6): 1583 - 1589.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. A. Willinek, J. Gieseke, R. Conrad, H. Strunk, R. Hoogeveen, M. von Falkenhausen, E. Keller, H. Urbach, C. K. Kuhl, and H. H. Schild
Randomly Segmented Central k-Space Ordering in High-Spatial-Resolution Contrast-enhanced MR Angiography of the Supraaortic Arteries: Initial Experience
Radiology, November 1, 2002; 225(2): 583 - 588.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Loewe, M. Schoder, T. Rand, U. Hoffmann, J. Sailer, T. Kos, J. Lammer, and S. Thurnher
Peripheral Vascular Occlusive Disease: Evaluation with Contrast-Enhanced Moving-Bed MR Angiography Versus Digital Subtraction Angiography in 106 Patients
Am. J. Roentgenol., October 1, 2002; 179(4): 1013 - 1021.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. S. Swan, T. J. Carroll, T. W. Kennell, D. M. Heisey, F. R. Korosec, R. Frayne, C. A. Mistretta, and T. M. Grist
Time-resolved Three-dimensional Contrast-enhanced MR Angiography of the Peripheral Vessels
Radiology, October 1, 2002; 225(1): 43 - 52.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Finn, V. Baskaran, J. C. Carr, R. M. McCarthy, F. S. Pereles, R. Kroeker, and G. A. Laub
Thorax: Low-Dose Contrast-enhanced Three-dimensional MR Angiography with Subsecond Temporal Resolution—Initial Results
Radiology, September 1, 2002; 224(3): 896 - 904.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
X. Leclerc, J.-F. Navez, J.-Y. Gauvrit, J.-P. Lejeune, and J.-P. Pruvo
Aneurysms of the Anterior Communicating Artery Treated with Guglielmi Detachable Coils: Follow-Up with Contrast-Enhanced MR Angiography
AJNR Am. J. Neuroradiol., August 1, 2002; 23(7): 1121 - 1127.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Geva, G. F. Greil, A. C. Marshall, M. Landzberg, and A. J. Powell
Gadolinium-Enhanced 3-Dimensional Magnetic Resonance Angiography of Pulmonary Blood Supply in Patients With Complex Pulmonary Stenosis or Atresia: Comparison With X-Ray Angiography
Circulation, July 23, 2002; 106(4): 473 - 478.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Goyen, H. H. Quick, J. F. Debatin, M. E. Ladd, J. Barkhausen, C. U. Herborn, S. Bosk, H. Kuehl, M. Schleputz, and S. G. Ruehm
Whole-Body Three-dimensional MR Angiography with a Rolling Table Platform: Initial Clinical Experience
Radiology, July 1, 2002; 224(1): 270 - 277.
[Abstract] [Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
N. Kawaharada, K. Morishita, J. Fukada, A. Yamada, S. Muraki, H. Hyodoh, and T. Abe
Thoracoabdominal or descending aortic aneurysm repair after preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography
Eur. J. Cardiothorac. Surg., June 1, 2002; 21(6): 970 - 974.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. S. Bradbury, P. V. Kavanagh, R. E. Bechtold, M. Y. Chen, D. J. Ott, J. D. Regan, and T. M. Weber
Mesenteric Venous Thrombosis: Diagnosis and Noninvasive Imaging
RadioGraphics, May 1, 2002; 22(3): 527 - 541.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. C. Carr, J. Ma, V. Desphande, S. Pereles, G. Laub, and J. P. Finn
High-Resolution Breath-Hold Contrast-Enhanced MR Angiography of the Entire Carotid Circulation
Am. J. Roentgenol., March 1, 2002; 178(3): 543 - 549.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
S. O. Schoenberg, M. V. Knopp, F. Londy, S. Krishnan, I. Zuna, N. Lang, M. Essig, H. Hawighorst, J. H. Maki, D. Stafford-Johnson, et al.
Morphologic and Functional Magnetic Resonance Imaging of Renal Artery Stenosis: A Multireader Tricenter Study
J. Am. Soc. Nephrol., January 1, 2002; 13(1): 158 - 169.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. V. Pandharipande, V. S. Lee, G. R. Morgan, L. W. Teperman, G. A. Krinsky, N. M. Rofsky, M.-C. Roy, and J. C. Weinreb
Vascular and Extravascular Complications of Liver Transplantation: Comprehensive Evaluation with Three-Dimensional Contrast-Enhanced Volumetric MR Imaging and MR Cholangiopancreatography
Am. J. Roentgenol., November 1, 2001; 177(5): 1101 - 1107.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. W. Goldfarb, M. G. Hochman, D. S. Kim, and R. R. Edelman
Contrast-Enhanced MR Angiography and Perfusion Imaging of the Hand
Am. J. Roentgenol., November 1, 2001; 177(5): 1177 - 1182.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. J. Carroll, F. R. Korosec, G. M. Petermann, T. M. Grist, and P. A. Turski
Carotid Bifurcation: Evaluation of Time-resolved Three-dimensional Contrast-enhanced MR Angiography
Radiology, August 1, 2001; 220(2): 525 - 532.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
T K Mittal, C Evans, T Perkins, and A M Wood
Renal arteriography using gadolinium enhanced 3D MR angiography--clinical experience with the technique, its limitations and pitfalls
Br. J. Radiol., June 1, 2001; 74(882): 495 - 502.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Manke, W. R. Nitz, B. Djavidani, M. Strotzer, M. Lenhart, M. Völk, S. Feuerbach, and J. Link
MR Imaging-guided Stent Placement in Iliac Arterial Stenoses: A Feasibility Study
Radiology, May 1, 2001; 219(2): 527 - 534.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
H. Masunaga, Y. Takehara, H. Isoda, T. Igarashi, M. Sugiyama, S. Isogai, N. Kodaira, H. Takeda, A. Nozaki, and H. Sakahara
Assessment of Gadolinium-Enhanced Time-Resolved Three-Dimensional MR Angiography for Evaluating Renal Artery Stenosis
Am. J. Roentgenol., May 1, 2001; 176(5): 1213 - 1219.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. U. Juergens, B. Tombach, P. Reimer, T. Vestring, and W. Heindel
Three-Dimensional Contrast-Enhanced MR Angiography of Endovascular Covered Stents in Patients with Peripheral Arterial Occlusive Disease
Am. J. Roentgenol., May 1, 2001; 176(5): 1299 - 1303.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. J. Spinosa, A. H. Matsumoto, J. F. Angle, K. D. Hagspiel, D. Cage, E. A. Bissonette, K. G. Koenig, C. R. Ayers, and K. McConnell
Safety of CO2- and Gadodiamide-Enhanced Angiography for the Evaluation and Percutaneous Treatment of Renal Artery Stenosis in Patients with Chronic Renal Insufficiency
Am. J. Roentgenol., May 1, 2001; 176(5): 1305 - 1311.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. A. Thurnher, A. Capelastegui, F. H. Del Olmo, R. F. Dondelinger, C. Gervás, A. G. Jassoy, P. Keto, C. Loewe, C. N. Ludman, L. Marti-Bonmati, et al.
Safety and Effectiveness of Single- versus Triple-Dose Gadodiamide Injection- enhanced MR Angiography of the Abdomen: A Phase III Double-Blind Multicenter Study
Radiology, April 1, 2001; 219(1): 137 - 146.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
J. F. Glockner
Three-dimensional Gadolinium-enhanced MR Angiography: Applications for Abdominal Imaging
RadioGraphics, March 1, 2001; 21(2): 357 - 370.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Nishida, G Sakai, A Morimoto, M Isota, T Kaminou, T Matsuoka, K Nakamura, and R Yamada
Gadolinium enhanced three-dimensional magnetic resonance portography with subtraction
Br. J. Radiol., February 1, 2001; 74(878): 147 - 152.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. T. Lavelle, V. S. Lee, N. M. Rofsky, G. A. Krinsky, and J. C. Weinreb
Dynamic Contrast-enhanced Three-dimensional MR Imaging of Liver Parenchyma: Source Images and Angiographic Reconstructions to Define Hepatic Arterial Anatomy
Radiology, February 1, 2001; 218(2): 389 - 394.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. B. Fain, B. F. King, J. F. Breen, D. G. Kruger, and S. J. Riederer
High-Spatial-Resolution Contrast-enhanced MR Angiography of the Renal Arteries: A Prospective Comparison with Digital Subtraction Angiography
Radiology, February 1, 2001; 218(2): 481 - 490.
[Abstract] [Full Text]


Home page
CirculationHome page
S. G. Ruehm, C. Corot, P. Vogt, S. Kolb, and J. F. Debatin
Magnetic Resonance Imaging of Atherosclerotic Plaque With Ultrasmall Superparamagnetic Particles of Iron Oxide in Hyperlipidemic Rabbits
Circulation, January 23, 2001; 103(3): 415 - 422.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
S. O. SCHOENBERG, M. BOCK, F. KALLINOWSKI, and A. JUST
Correlation of Hemodynamic Impact and Morphologic Degree of Renal Artery Stenosis in a Canine Model
J. Am. Soc. Nephrol., December 1, 2000; 11(12): 2190 - 2198.
[Abstract] [Full Text]


Home page
RadiologyHome page
M. Lenhart, M. Völk, C. Manke, W. R. Nitz, M. Strotzer, S. Feuerbach, and J. Link
Stent Appearance at Contrast-enhanced MR Angiography: In Vitro Examination with 14 Stents
Radiology, October 1, 2000; 217(1): 173 - 178.
[Abstract] [Full Text]


Home page
CirculationHome page
R. J. M. van Geuns, M. Oudkerk, P. J. de Feyter, and S. E. Spitaels
Magnetic Resonance Angiography of a Pulmonary Artery Stenosis Late After Cardiac Surgery
Circulation, September 12, 2000; 102 (11): e71 - e72.
[Full Text] [PDF]


Home page
RadiologyHome page
K. Mitsuzaki, Y. Yamashita, T. Sakaguchi, I. Ogata, M. Takahashi, and Y. Hiai
Abdomen, Pelvis, and Extremities: Diagnostic Accuracy of Dynamic Contrast-enhanced Turbo MR Angiography Compared with Conventional Angiography-Initial Experience
Radiology, September 1, 2000; 216(3): 909 - 915.
[Abstract] [Full Text]