Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blum, U.
Right arrow Articles by Cragg, A. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blum, U.
Right arrow Articles by Cragg, A. H.

Radiology, Vol 198, 25-31, Copyright © 1996 by Radiological Society of North America


ARTICLES

Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts

U Blum, M Langer, G Spillner, C Mialhe, F Beyersdorf, C Buitrago-Tellez, G Voshage, C Duber, V Schlosser and AH Cragg
Department of Diagnostic Radiology, University Hospital Freiburg, Germany.

PURPOSE: To evaluate treatment of infrarenal abdominal aortic aneurysm (AAA) with a new endoluminal stent-graft. MATERIALS AND METHODS: In 26 male patients, straight or bifurcated nitinol stents covered with woven Dacron graft material were implanted to treat eccentric saccular AAA (n = 3) or AAA involving the bifurcation and common iliac arteries (n = 23), with follow-up from 8 days to 8 1/2 months. RESULTS: Implantation was technically successful in all but one of the 26 (96%) patients (leak of the stent-graft for more than 3 months necessitated implantation of an additional covered stent). In seven of the 26 patients, minor residual perfusion persisted immediately after implantation, but complete thrombosis occurred within 7 days. Five procedure-related complications occurred: distal embolization (n = 2); local hematoma, which necessitated surgery (n = 1); acute hepatic failure due to gastric bleeding, in a patient with liver cirrhosis (n = 1); and stent-graft occlusion due to emboli originating from the left atrium (n = 1). CONCLUSION: Exclusion of AAA from circulation was feasible, safe, and clinically effective with the new stent-graft.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
M. Czerny, M. Grimm, D. Zimpfer, S. Rodler, R. Gottardi, D. Hutschala, J. Lammer, E. Wolner, and M. Schoder
Results After Endovascular Stent Graft Placement in Atherosclerotic Aneurysms Involving the Descending Aorta
Ann. Thorac. Surg., February 1, 2007; 83(2): 450 - 455.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Neragi-Miandoab, J. Tuchak, M. Bakhos, and J. P. Schwartz
Open repair of a new aneurysm of the thoracoabdominal aorta after endovascular stent placement
J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 157 - 158.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y.-C. Weon, S.-G. Kang, J. W. Chung, Y. I. Kim, J. H. Park, and D. Y. Lee
Technical feasibility and biocompatibility of a newly designed separating stent-graft in the normal canine aorta.
Am. J. Roentgenol., April 1, 2006; 186(4): 1148 - 1154.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. M. Auyeung, W. M. Lui, L. C.K. Chow, and F. L. Chan
Massive Epistaxis Related to Petrous Carotid Artery Pseudoaneurysm After Radiation Therapy: Emergency Treatment with Covered Stent in Two Cases
AJNR Am. J. Neuroradiol., August 1, 2003; 24(7): 1449 - 1452.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. M. Rozenblit, M. Patlas, A. T. Rosenbaum, T. Okhi, F. J. Veith, M. P. Laks, and Z. J. Ricci
Detection of Endoleaks after Endovascular Repair of Abdominal Aortic Aneurysm: Value of Unenhanced and Delayed Helical CT Acquisitions
Radiology, May 1, 2003; 227(2): 426 - 433.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. C. G. Simons, H. van Overhagen, C. M. A. Bruijninckx, R. F. Kropman, and K. C. Kuijpers
Periaortitis with Ureteral Obstruction After Endovascular Repair of an Abdominal Aortic Aneurysm
Am. J. Roentgenol., July 1, 2002; 179(1): 118 - 120.
[Full Text] [PDF]


Home page
CirculationHome page
G. Sangiorgi, R. D'Averio, A. Mauriello, M. Bondio, M. Pontillo, S. Castelvecchio, S. Trimarchi, V. Tolva, G. Nano, V. Rampoldi, et al.
Plasma Levels of Metalloproteinases-3 and -9 as Markers of Successful Abdominal Aortic Aneurysm Exclusion After Endovascular Graft Treatment
Circulation, September 18, 2001; 104(90001): I-288 - 295.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Tillich, B. B. Hill, D. S. Paik, K. Petz, S. Napel, C. K. Zarins, and G. D. Rubin
Prediction of Aortoiliac Stent-Graft Length: Comparison of Measurement Methods
Radiology, August 1, 2001; 220(2): 475 - 483.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S.-G. Kang, D. Y. Lee, M. Maeda, E. S. Kim, D. Choi, B.-O. Kim, H. K. Yoon, K. B. Sung, and H.-Y. Song
Aortic Dissection: Percutaneous Management with a Separating Stent-Graft—Preliminary Results
Radiology, August 1, 2001; 220(2): 533 - 539.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Sawhney, R. K. Kerlan, S. D. Wall, T. A. M. Chuter, D. E. Ruiz, C. J. Canto, J. M. LaBerge, L. M. Reilly, J. Yee, M. W. Wilson, et al.
Analysis of Initial CT Findings after Endovascular Repair of Abdominal Aortic Aneurysm
Radiology, July 1, 2001; 220(1): 157 - 160.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Tillich, R. E. Bell, D. S. Paik, D. Fleischmann, M. C. Sofilos, L. J. Logan, and G. D. Rubin
Iliac Arterial Injuries after Endovascular Repair of Abdominal Aortic Aneurysms: Correlation with Iliac Curvature and Diameter
Radiology, April 1, 2001; 219(1): 129 - 136.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
T. Mita, T. Arita, N. Matsunaga, M. Furukawa, N. Zempo, K. Esato, and M. Matsuzaki
Complications of Endovascular Repair for Thoracic and Abdominal Aortic Aneurysm: An Imaging Spectrum
RadioGraphics, September 1, 2000; 20(5): 1263 - 1278.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Ishiguchi, N. Nishikimi, A. Usui, and T. Ishigaki
Endovascular Stent-Graft Deployment: Temporary Vena Caval Occlusion with Balloons to Control Aortic Blood Flow-Experimental Canine Study and Initial Clinical Experience
Radiology, May 1, 2000; 215(2): 594 - 599.
[Abstract] [Full Text]


Home page
RadiologyHome page
M. D. Armerding, G. D. Rubin, C. F. Beaulieu, S. M. Slonim, E. W. Olcott, S. L. Samuels, M. J. Jorgensen, C. P. Semba, R. B. Jeffrey Jr, and M. D. Dake
Aortic Aneurysmal Disease: Assessment of Stent-Graft Treatment-CT versus Conventional Angiography
Radiology, April 1, 2000; 215(1): 138 - 146.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
J. L. Fidler, J. P. Cheatham, S. E. Fletcher, A. B. Martin, J. D. Kugler, C. H. Gumbiner, and D. A. Danford
CT Angiography of Complications in Pediatric Patients Treated with Intravascular Stents
Am. J. Roentgenol., February 1, 2000; 174(2): 355 - 359.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Thalhammer, A. S. Kirchherr, F. Uhlich, J. Waigand, and C. M. Gross
Postcatheterization Pseudoaneurysms and Arteriovenous Fistulas: Repair with Percutaneous Implantation of Endovascular Covered Stents1
Radiology, January 1, 2000; 214(1): 127 - 131.
[Abstract] [Full Text]


Home page
RadiologyHome page
J. Görich, N. Rilinger, R. Sokiranski, K.-H. Orend, C. Ermis, S. C. Krämer, H.-J. Brambs, L. Sunder-Plassmann, and R. Pamler
Leakages after Endovascular Repair of Aortic Aneurysms: Classification Based on Findings at CT, Angiography, and Radiography
Radiology, December 1, 1999; 213(3): 767 - 772.
[Abstract] [Full Text]


Home page
HeartHome page
A G Magee, G Brzezinska-Rajszys, S A Qureshi, E Rosenthal, M Zubrzycka, J Ksiazyk, and M Tynan
Stent implantation for aortic coarctation and recoarctation
Heart, November 1, 1999; 82(5): 600 - 606.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
M. Tillich, K. A. Hausegger, K. Tiesenhausen, J. Tauss, R. Groell, and D. H. Szolar
Helical CT Angiography of Stent-Grafts in Abdominal Aortic Aneurysms: Morphologic Changes and Complications
RadioGraphics, November 1, 1999; 19(6): 1573 - 1583.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Sakai, M. D. Dake, C. P. Semba, T. Yamada, A. Arakawa, S. T. Kee, N. Hayashi, M. K. Razavi, and D. Y. Sze
Descending Thoracic Aortic Aneurysm: Thoracic CT Findings after Endovascular Stent-Graft Placement
Radiology, July 1, 1999; 212(1): 169 - 174.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
R. S. Mitchell, D. C. Miller, M. D. Dake, C. P. Semba, K. A. Moore, and T. Sakai
Thoracic aortic aneurysm repair with an endovascular stent graft: the ""first generation""
Ann. Thorac. Surg., June 1, 1999; 67(6): 1971 - 1974.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Schellhammer, M. Walter, A. Berlis, H.-G. Bloss, E. Wellens, and M. Schumacher
Polyethylene Terephthalate and Polyurethane Coatings for Endovascular Stents: Preliminary Results in Canine Experimental Arteriovenous Fistulas
Radiology, April 1, 1999; 211(1): 169 - 175.
[Abstract] [Full Text]


Home page
CirculationHome page
C. E. Ruiz, H. P. Zhang, A. I. Butt, and P. Whittaker
Percutaneous Treatment of Abdominal Aortic Aneurysm in a Swine Model : Understanding the Behavior of Aortic Aneurysm Closure Through a Serial Histopathological Analysis
Circulation, October 7, 1997; 96(7): 2438 - 2448.
[Abstract] [Full Text]


Home page
NEJMHome page
U. Blum, G. Voshage, J. Lammer, F. Beyersdorf, D. Tollner, G. Kretschmer, G. Spillner, P. Polterauer, G. Nagel, T. Holzenbein, et al.
Endoluminal Stent-Grafts for Infrarenal Abdominal Aortic Aneurysms
N. Engl. J. Med., January 2, 1997; 336(1): 13 - 20.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
C. B. Ernst
Current Therapy for Infrarenal Aortic Aneurysms
N. Engl. J. Med., January 2, 1997; 336(1): 58 - 60.
[Full Text]


Home page
RadiologyHome page
T. Kuehne, M. Saeed, P. Moore, K. Gleason, G. Reddy, D. Teitel, and C. B. Higgins
Influence of Blood-Pool Contrast Media on MR Imaging and Flow Measurements in the Presence of Pulmonary Arterial Stents in Swine
Radiology, May 1, 2002; 223(2): 439 - 445.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. B. Pitton, R. P. Schmenger, A. Neufang, M. A. Konerding, C. Duber, and M. Thelen
Endovascular Aneurysm Repair: Magnetic Resonance Monitoring of Histological Organization Processes in the Excluded Aneurysm
Circulation, April 23, 2002; 105(16): 1995 - 1999.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.