Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wang, Y.
Right arrow Articles by Ehman, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, Y.
Right arrow Articles by Ehman, R. L.

Radiology, Vol 198, 55-60, Copyright © 1996 by Radiological Society of North America


ARTICLES

Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography

Y Wang, PJ Rossman, RC Grimm, SJ Riederer and RL Ehman
Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905, USA.

PURPOSE: To test the hypothesis that respiration effects in three- dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Real-time respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real- time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory- gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
B. S. Kim, J. H. Kim, G. M. Choi, S. H. Kim, J. K. Park, B.-C. Song, and W. Kang
Comparison of Three Free-Breathing T2-Weighted MRI Sequences in the Evaluation of Focal Liver Lesions
Am. J. Roentgenol., January 1, 2008; 190(1): W19 - W27.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M. Eichinger, M. Puderbach, H-J. Smith, R. Tetzlaff, A. Kopp-Schneider, M. Bock, J. Biederer, and H-U. Kauczor
Magnetic resonance-compatible-spirometry: principle, technical evaluation and application
Eur. Respir. J., November 1, 2007; 30(5): 972 - 979.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. W. van der Meer, J. Doornbos, S. Kozerke, M. Schar, J. J. Bax, S. Hammer, MSc, J. W. A. Smit, J. A. Romijn, M. Diamant, L. J. Rijzewijk, et al.
Metabolic Imaging of Myocardial Triglyceride Content: Reproducibility of 1H MR Spectroscopy with Respiratory Navigator Gating in Volunteers
Radiology, October 1, 2007; 245(1): 251 - 257.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Wyttenbach, A. Braghetti, M. Wyss, M. Alerci, L. Briner, P. Santini, L. Cozzi, M. Di Valentino, M. Katoh, C. Marone, et al.
Renal Artery Assessment with Nonenhanced Steady-State Free Precession versus Contrast-enhanced MR Angiography
Radiology, October 1, 2007; 245(1): 186 - 195.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Takemura, A. Suzuki, R. Inaba, T. Sonobe, K. Tsuchiya, M. Omuro, and T. Korenaga
Utility of Coronary MR Angiography in Children with Kawasaki Disease
Am. J. Roentgenol., June 1, 2007; 188(6): W534 - W539.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. C. Peters, J. V. Wylie, T. H. Hauser, K. V. Kissinger, R. M. Botnar, V. Essebag, M. E. Josephson, and W. J. Manning
Detection of Pulmonary Vein and Left Atrial Scar after Catheter Ablation with Three-dimensional Navigator-gated Delayed Enhancement MR Imaging: Initial Experience
Radiology, March 1, 2007; 243(3): 690 - 695.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Muthupillai, J. Smink, S. Hong, R. Ravindran, V. V. Lee, and S. D. Flamm
SENSE or k-MAG to accelerate free breathing navigator-guided coronary MR angiography.
Am. J. Roentgenol., June 1, 2006; 186(6): 1669 - 1675.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. L. Wilensky, H. K. Song, and V. A. Ferrari
Role of magnetic resonance and intravascular magnetic resonance in the detection of vulnerable plaques.
J. Am. Coll. Cardiol., April 18, 2006; 47(8 Suppl): C48 - C56.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. M. Kramer
The comprehensive approach to ischemic heart disease by cardiovascular magnetic resonance imaging: Are we there yet?
J. Am. Coll. Cardiol., December 7, 2004; 44(11): 2182 - 2184.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. J. Budoff, S. Achenbach, and A. Duerinckx
Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography
J. Am. Coll. Cardiol., December 3, 2003; 42(11): 1867 - 1878.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. S. Dirksen, H. J. Lamb, P. Kunz, P. Robert, C. Corot, and A. de Roos
Improved MR Coronary Angiography with Use of a New Rapid Clearance Blood Pool Contrast Agent in Pigs
Radiology, June 1, 2003; 227(3): 802 - 808.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Plein, S. Bulugahapitiya, T. R. Jones, G. J. Bainbridge, J. P. Ridgway, and M. U. Sivananthan
Cardiac MR Imaging with External Respirator: Synchronizing Cardiac and Respiratory Motion—Feasibility Study
Radiology, June 1, 2003; 227(3): 877 - 882.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. M. McCarthy, S. M. Shea, V. S. Deshpande, J. D. Green, F. S. Pereles, J. C. Carr, J. P. Finn, and D. Li
Coronary MR Angiography: True FISP Imaging Improved by Prolonging Breath Holds with Preoxygenation in Healthy Volunteers
Radiology, April 1, 2003; 227(1): 283 - 288.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Spuentrup, W. J. Manning, P. Bornert, K. V. Kissinger, R. M. Botnar, and M. Stuber
Renal Arteries: Navigator-gated Balanced Fast Field-Echo Projection MR Angiography with Aortic Spin Labeling: Initial Experience
Radiology, November 1, 2002; 225(2): 589 - 596.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
D J Sahn and G W Vick III
Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease
Heart, December 1, 2001; 86(90002): ii41 - 53.
[Full Text] [PDF]


Home page
RadiologyHome page
D. Li, J. C. Carr, S. M. Shea, J. Zheng, V. S. Deshpande, P. A. Wielopolski, and J. P. Finn
Coronary Arteries: Magnetization-prepared Contrast-enhanced Three-dimensional Volume-targeted Breath-hold MR Angiography
Radiology, April 1, 2001; 219(1): 270 - 277.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
K. P. McGee, J. P. Felmlee, C. R. Jack Jr., A. Manduca, S. J. Riederer, and R. L. Ehman
Autocorrection of Three-Dimensional Time-of-Flight MR Angiography of the Circle of Willis
Am. J. Roentgenol., February 1, 2001; 176(2): 513 - 518.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Wang, R. Watts, I. R. Mitchell, T. D. Nguyen, J. W. Bezanson, G. W. Bergman, and M. R. Prince
Coronary MR Angiography: Selection of Acquisition Window of Minimal Cardiac Motion with Electrocardiography-triggered Navigator Cardiac Motion Prescanning--Initial Results
Radiology, February 1, 2001; 218(2): 580 - 585.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
M. Regenfus, D. Ropers, S. Achenbach, W. Kessler, G. Laub, W. G. Daniel, and W. Moshage
Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography
J. Am. Coll. Cardiol., July 1, 2000; 36(1): 44 - 50.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Wang, P. A. Winchester, L. Yu, R. Watts, G. Ding, H. M. Lee, and G. W. Bergman
Breath-Hold Three-dimensional Contrast-enhanced Coronary MR Angiography: Motion-matched k-Space Sampling for Reducing Cardiac Motion Effects
Radiology, May 1, 2000; 215(2): 600 - 607.
[Abstract] [Full Text]


Home page
RadiologyHome page
F. Sardanelli, G. Molinari, F. Zandrino, and M. Balbi
Three-dimensional, Navigator-Echo MR Coronary Angiography in Detecting Stenoses of the Major Epicardial Vessels, with Conventional Coronary Angiography as the Standard of Reference
Radiology, March 1, 2000; 214(3): 808 - 814.
[Abstract] [Full Text]


Home page
RadiologyHome page
Y. Wang, E. Vidan, and G. W. Bergman
Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR Angiography
Radiology, December 1, 1999; 213(3): 751 - 758.
[Abstract] [Full Text]


Home page
CirculationHome page
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce
Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries
Circulation, November 30, 1999; 100(22): 2284 - 2301.
[Full Text] [PDF]


Home page
HeartHome page
R J M van Geuns, H G de Bruin, B J W M Rensing, P A Wielopolski, M D Hulshoff, P M A van Ooijen, M Oudkerk, and P J de Feyter
Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique
Heart, October 1, 1999; 82(4): 515 - 519.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Stuber, R. M. Botnar, P. G. Danias, D. K. Sodickson, K. V. Kissinger, M. Van Cauteren, J. De Becker, and W. J. Manning
Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography
J. Am. Coll. Cardiol., August 1, 1999; 34(2): 524 - 531.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Stuber, R. M. Botnar, P. G. Danias, K. V. Kissinger, and W. J. Manning
Submillimeter Three-dimensional Coronary MR Angiography with Real-time Navigator Correction: Comparison of Navigator Locations
Radiology, August 1, 1999; 212(2): 579 - 587.
[Abstract] [Full Text]


Home page
CirculationHome page
R. M. Botnar, M. Stuber, P. G. Danias, K. V. Kissinger, and W. J. Manning
Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Circulation, June 22, 1999; 99(24): 3139 - 3148.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. H. Ahlström, L. O. Johansson, J. B. Rodenburg, A. S. Ragnarsson, P. Åkeson, and A. Börseth
Pulmonary MR Angiography with Ultrasmall Superparamagnetic Iron Oxide Particles as a Blood Pool Agent and a Navigator Echo for Respiratory Gating: Pilot Study
Radiology, June 1, 1999; 211(3): 865 - 869.
[Abstract] [Full Text]


Home page
RadiologyHome page
E. K. Yucel
Pulmonary MR Angiography: Is It Ready Now?
Radiology, February 1, 1999; 210(2): 301 - 303.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.