Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harika, L.
Right arrow Articles by Papisov, M. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harika, L.
Right arrow Articles by Papisov, M. I.

Radiology, Vol 198, 365-370, Copyright © 1996 by Radiological Society of North America


ARTICLES

Macromolecular intravenous contrast agent for MR lymphography: characterization and efficacy studies

L Harika, R Weissleder, K Poss and MI Papisov
Department of Radiology, Massachusetts General Hospital, Boston, USA.

PURPOSE: To determine the pharmacokinetic and magnetic resonance (MR) imaging properties of diethylenetriaminepentaacetic acid (DTPA) conjugated with a polyglucose-associated macrocomplex (PGM), which accumulates in lymph nodes. MATERIALS AND METHODS: In 124 normal and 20 tumor-bearing rats, Gd-DTPA PGM was administered intravenously in doses of 2, 10, 20 mumol gadolinium per kilogram of tissue. RESULTS: Mean blood half-life was 2 hours. Maximum accumulation in peripheral (33.0% injected dose [ID]/g +/- 16.2 [standard deviation]) and central lymph nodes (63.2% ID/g +/- 16.5) was observed within 24 hours after administration. The optimum dose range was 10-20 mumol Gd/kg in rats. At 24 hours after administration of 20 mumol Gd/kg, the signal-to-noise ratio increased from 30.9 +/- 0.4 to 83.2 +/- 5.2 in normal lymph nodes (P < .001). Differentiation between normal and metastatic lymph nodes was improved. CONCLUSION: When labeled with Gd-DTPA, the PGM-based graft copolymer significantly increases signal intensity at MR imaging of normal but not metastatic lymph nodes without causing distortion artifacts.


This article has been cited by other articles:


Home page
RadiologyHome page
B. Misselwitz, J. Platzek, and H.-J. Weinmann
Early MR Lymphography with Gadofluorine M in Rabbits
Radiology, June 1, 2004; 231(3): 682 - 688.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. G. Torchia and B. Misselwitz
Combined MR Lymphangiography and MR Imaging--Guided Needle Localization of Sentinel Lymph Nodes Using Gadomer-17
Am. J. Roentgenol., December 1, 2002; 179(6): 1561 - 1565.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. U. Herborn, T. C. Lauenstein, F. M. Vogt, R. B. Lauffer, J. F. Debatin, and S. G. Ruehm
Interstitial MR Lymphography with MS-325: Characterization of Normal and Tumor-Invaded Lymph Nodes in a Rabbit Model
Am. J. Roentgenol., December 1, 2002; 179(6): 1567 - 1572.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Staatz, C. C. A. Nolte-Ernsting, G. B. Adam, S. Grosskortenhaus, B. Misselwitz, A. Bucker, and R. W. Gunther
Interstitial T1-weighted MR Lymphography: Lipophilic Perfluorinated Gadolinium Chelates in Pigs
Radiology, July 1, 2001; 220(1): 129 - 134.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. G. Mack, J. O. Balzer, R. Straub, K. Eichler, and T. J. Vogl
Superparamagnetic Iron Oxide-enhanced MR Imaging of Head and Neck Lymph Nodes
Radiology, January 1, 2002; 222(1): 239 - 244.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.