Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moritz, J. D.
Right arrow Articles by Oestmann, J. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moritz, J. D.
Right arrow Articles by Oestmann, J. W.

Radiology, Vol 198, 463-466, Copyright © 1996 by Radiological Society of North America


ARTICLES

Infrarenal abdominal aortic aneurysms: implications of CT evaluation of size and configuration for placement of endovascular aortic grafts

JD Moritz, S Rotermund, DP Keating and JW Oestmann
Department of Radiology, University Hospital of Gottingen, Germany.

PURPOSE: To measure infrarenal abdominal aortic aneurysms and assess the implications and potential obstacles for placement of an endovascular aortic graft undergoing clinical testing in Europe. MATERIALS AND METHODS: Helical computed tomography was used to measure 77 infrarenal aortic aneurysms (77 patients) and the distances between the aneurysms and the renal arteries and the aortic bifurcation. RESULTS: Mean length of the aneurysms was 8.2 cm; mean distance to the renal arteries, 2.7 cm; mean aortic diameter 1.5 cm distal to the renal arteries, 1.9 cm; and mean minimal diameter of perfused lumen, 2.5 cm. Thirteen aneurysms extended into the common iliac artery; 40 reached the bifurcation. The mean minimal luminal diameter of the iliac artery was 1.1 cm. CONCLUSION: Sufficient nonaneurysmal segments below the renal arteries and distal to the aneurysms are necessary for stent fixation. The large diameter of the delivery introducer in relation to the iliac arteries may be a major obstacle to graft delivery. At best, 33 patients could have benefited from use of the graft evaluated.


This article has been cited by other articles:


Home page
RadiologyHome page
J. L. Bosch, J. A. Kaufman, M. T. Beinfeld, M. E. A. P. M. Adriaensen, D. C. Brewster, and G. S. Gazelle
Abdominal Aortic Aneurysms: Cost-effectiveness of Elective Endovascular and Open Surgical Repair
Radiology, November 1, 2002; 225(2): 337 - 344.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Tillich, B. B. Hill, D. S. Paik, K. Petz, S. Napel, C. K. Zarins, and G. D. Rubin
Prediction of Aortoiliac Stent-Graft Length: Comparison of Measurement Methods
Radiology, August 1, 2001; 220(2): 475 - 483.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. D. Qanadli, B. Mesurolle, M. Coggia, O. Barre, S. Fukui, O. A. Goeau-Brissonniere, S. Chagnon, and P. Lacombe
Abdominal Aortic Aneurysm: Pretherapy Assessment with Dual-Slice Helical CT Angiography
Am. J. Roentgenol., January 1, 2000; 174(1): 181 - 187.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.