PURPOSE: To evaluate endovascular stent-graft placement for management of aortoiliac aneurysms. MATERIALS AND METHODS: Balloon-expandable stents covered with polytetrafluoroethylene were placed in 11 aortoiliac lesions in nine male non-surgical candidates (mean age, 63.5 years). There were six abdominal aortic aneurysms, four iliac artery aneurysms, and one acute pseudoaneurysm from a ruptured iliac artery. Stent-grafts were dilated up to 14 mm (iliac) and 24 mm (aorta). Patients underwent follow-up computed tomography and angiography. RESULTS: Stent-grafts were successfully placed in all 11 cases. There were two complications: a ruptured iliac artery treated with placement of an additional covered stent and a lower-extremity vessel embolization and bowel infarction resulting in death. All stent-grafts remained patent without increased aneurysmal diameter. Three leaks (27%) were detected. Two leaks were treated with placement of additional covered stents. One still is asymptomatic. CONCLUSION: Endovascular treatment of aortoiliac aneurysms with stent-graft devices may be an alternative to surgery.
This article has been cited by other articles:
![]() |
C. Hong, J. P. Heiken, G. A. Sicard, T. K. Pilgram, and K. T. Bae Clinical Significance of Endoleak Detected on Follow-Up CT After Endovascular Repair of Abdominal Aortic Aneurysm Am. J. Roentgenol., September 1, 2008; 191(3): 808 - 813. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Rozenblit, M. Patlas, A. T. Rosenbaum, T. Okhi, F. J. Veith, M. P. Laks, and Z. J. Ricci Detection of Endoleaks after Endovascular Repair of Abdominal Aortic Aneurysm: Value of Unenhanced and Delayed Helical CT Acquisitions Radiology, May 1, 2003; 227(2): 426 - 433. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Greenfield, E. J. Halpern, J. Bonn, R. J. Wechsler, and M. B. Kahn Application of Duplex US for Characterization of Endoleaks in Abdominal Aortic Stent-Grafts: Report of Five Cases Radiology, December 1, 2002; 225(3): 845 - 851. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Schoder, L. Zaunbauer, T. Holzenbein, D. Fleischmann, M. Cejna, G. Kretschmer, S. Thurnher, and J. Lammer Internal Iliac Artery Embolization Before Endovascular Repair of Abdominal Aortic Aneurysms: Frequency, Efficacy, and Clinical Results Am. J. Roentgenol., September 1, 2001; 177(3): 599 - 605. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Park, J. W. Chung, J. H. Joh, S. Y. Song, S. J. Shin, K. S. Chung, D. Y. Lee, J. Y. Won, and S. J. Kim Aortic and Arterial Aneurysms in Behcet Disease: Management with Stent-Grafts—Initial Experience Radiology, September 1, 2001; 220(3): 745 - 750. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Sawhney, R. K. Kerlan, S. D. Wall, T. A. M. Chuter, D. E. Ruiz, C. J. Canto, J. M. LaBerge, L. M. Reilly, J. Yee, M. W. Wilson, et al. Analysis of Initial CT Findings after Endovascular Repair of Abdominal Aortic Aneurysm Radiology, July 1, 2001; 220(1): 157 - 160. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Mita, T. Arita, N. Matsunaga, M. Furukawa, N. Zempo, K. Esato, and M. Matsuzaki Complications of Endovascular Repair for Thoracic and Abdominal Aortic Aneurysm: An Imaging Spectrum RadioGraphics, September 1, 2000; 20(5): 1263 - 1278. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ishiguchi, N. Nishikimi, A. Usui, and T. Ishigaki Endovascular Stent-Graft Deployment: Temporary Vena Caval Occlusion with Balloons to Control Aortic Blood Flow-Experimental Canine Study and Initial Clinical Experience Radiology, May 1, 2000; 215(2): 594 - 599. [Abstract] [Full Text] |
||||
![]() |
J. L. Fidler, J. P. Cheatham, S. E. Fletcher, A. B. Martin, J. D. Kugler, C. H. Gumbiner, and D. A. Danford CT Angiography of Complications in Pediatric Patients Treated with Intravascular Stents Am. J. Roentgenol., February 1, 2000; 174(2): 355 - 359. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Thalhammer, A. S. Kirchherr, F. Uhlich, J. Waigand, and C. M. Gross Postcatheterization Pseudoaneurysms and Arteriovenous Fistulas: Repair with Percutaneous Implantation of Endovascular Covered Stents1 Radiology, January 1, 2000; 214(1): 127 - 131. [Abstract] [Full Text] |
||||
![]() |
U. Blum, G. Voshage, J. Lammer, F. Beyersdorf, D. Tollner, G. Kretschmer, G. Spillner, P. Polterauer, G. Nagel, T. Holzenbein, et al. Endoluminal Stent-Grafts for Infrarenal Abdominal Aortic Aneurysms N. Engl. J. Med., January 2, 1997; 336(1): 13 - 20. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Pitton, R. P. Schmenger, A. Neufang, M. A. Konerding, C. Duber, and M. Thelen Endovascular Aneurysm Repair: Magnetic Resonance Monitoring of Histological Organization Processes in the Excluded Aneurysm Circulation, April 23, 2002; 105(16): 1995 - 1999. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |