|
|
||||||||
Radiology, Vol 198, 573-578, Copyright © 1996 by Radiological Society of North America
ARTICLES |
F Kimura, Y Shen, S Date, S Azemoto and T Mochizuki
Department of Radiology, Tsuchiya General Hospital, Hiroshima-shi, Japan.
Three-dimensional (3D) endoscopic-mode software was used at helical computed tomography (CT) to evaluate distal aortic arch aneurysms (n = 12) and aortic dissections (n = 10); images were compared with two- dimensional (2D) axial source images. In distal aortic arch aneurysms, the 3D endoscopic mode depicted the relationship of the arterial orifices and the aneurysm, which is difficult to evaluate with 2D axial images alone. In aortic dissections, however, the 3D endoscopic mode did not provide additional information to that provided on the 2D axial source images.
This article has been cited by other articles:
![]() |
Q. Liu, J. P. Lu, F. Wang, L. Wang, and J. M. Tian Three-dimensional Contrast-enhanced MR Angiography of Aortic Dissection: A Pictorial Essay RadioGraphics, September 1, 2007; 27(5): 1311 - 1321. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. C. Dalrymple, S. R. Prasad, M. W. Freckleton, and K. N. Chintapalli Informatics in Radiology (infoRAD): Introduction to the Language of Three-dimensional Imaging with Multidetector CT RadioGraphics, September 1, 2005; 25(5): 1409 - 1428. [Abstract] [Full Text] [PDF] |
||||
![]() |
N Rilinger, H Seifarth, R Sokiranski, S Kramer, F Liewald, J Goerich, A Tomzcak, and C E E Nierhoff Virtual intra-arterial angioscopy (VIA) of the carotid artery based on helical CT data Br. J. Radiol., November 1, 2003; 76(911): 792 - 797. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Morgan-Hughes, A. J. Marshall, and C. Roobottom Morphologic Assessment of Patent Ductus Arteriosus in Adults Using Retrospectively ECG-Gated Multidetector CT Am. J. Roentgenol., September 1, 2003; 181(3): 749 - 754. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. P. Lawler and E. K. Fishman Multi-Detector Row CT of Thoracic Disease with Emphasis on 3D Volume Rendering and CT Angiography RadioGraphics, September 1, 2001; 21(5): 1257 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Nakanishi, M. Kohata, K. Miyasaka, H. Fukuoka, K. Ito, and M. Imazu Virtual Endoscopy of Coronary Arteries Using Contrast-Enhanced ECG-Triggered Electron Beam CT Data Sets Am. J. Roentgenol., May 1, 2000; 174(5): 1345 - 1347. [Full Text] [PDF] |
||||
![]() |
E. Neri, D. Caramella, F. Falaschi, P. Sbragia, C. Vignali, E. Laiolo, A. Viviani, and C. Bartolozzi Virtual CT Intravascular Endoscopy of the Aorta: Pierced Surface and Floating Shape Thresholding Artifacts Radiology, July 1, 1999; 212(1): 276 - 279. [Abstract] [Full Text] |
||||
![]() |
K. Saku, Y. Takeda, T. Nii, K. Shirai, M. Okabe, T. Ohta, K. Arakawa, and K. Saku Three-Dimensional Spiral Computed Tomography Angiography as an Alternative Imaging Modality for a Silent Dissecting Aortic Aneurysm: A Case Report Angiology, December 1, 1997; 48(12): 1067 - 1071. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |