|
|
||||||||
Radiology, Vol 198, 733-739, Copyright © 1996 by Radiological Society of North America
ARTICLES |
D Saloner, R van Tyen, WP Dillon, LD Jou and SA Berger
Radiology Service, Veteran's Administration Medical Center, San Francisco, California 94121, USA.
PURPOSE: To investigate the appearance of reduced signal intensity in the center of blood vessels on magnetic resonance (MR) angiograms that can mimic intraluminal thrombus. MATERIALS AND METHODS: Simulations and phantom studies were performed to analyze MR angiogram appearance distal to a pronounced curve. RESULTS: Saturation effects substantially lower the signal strength in the center of the vessel relative to that at the vessel periphery. These effects appeared even though the flow was well ordered and laminar. In curved geometries, secondary flow patterns produced counter-rotating vortices, which moved the fastest- moving particles to the outside of the curve and folded the slow-moving particles to the center of the vessel. CONCLUSION: Imaging parameter choices that reduce saturation, such as acquisition of a two- dimensional section transverse to the vessel and through the questionable region, effectively eliminate the central hypointensity effect in vivo.
This article has been cited by other articles:
![]() |
S. Wetzel, S. Meckel, A. Frydrychowicz, L. Bonati, E.-W. Radue, K. Scheffler, J. Hennig, and M. Markl In Vivo Assessment and Visualization of Intracranial Arterial Hemodynamics with Flow-Sensitized 4D MR Imaging at 3T AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 433 - 438. [Abstract] [Full Text] [PDF] |
||||
![]() |
K.-M. Han, L. E. M. Duijm, G. R. P. Thelissen, P. W. M. Cuypers, P. Douwes-Draaijer, A. V. Tielbeek, J. H. M. Wondergem, and H. C. M. van den Bosch Failing Hemodialysis Access Grafts: Evaluation of Complete Vascular Tree with 3D Contrast-enhanced MR Angiography with High Spatial Resolution: Initial Results in 10 Patients Radiology, May 1, 2003; 227(2): 601 - 605. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. M. Smits, C. Bos, O. E. H. Elgersma, W. A. M. A. van der Mark, P. J. Blankestijn, C. J. G. Bakker, J. J. Zijlstra, S. Kalmijn, and W. P. T. M. Mali Hemodialysis Access Imaging: Comparison of Flow-interrupted Contrast-enhanced MR Angiography and Digital Subtraction Angiography Radiology, December 1, 2002; 225(3): 829 - 834. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. G. Ryan, G. H. Westrich, H. G. Potter, N. Sharrock, L. M. Maun, W. Macaulay, P. Katkin, T. P. Sculco, and E. A. Salvati Effect of Mechanical Compression on the Prevalence of Proximal Deep Venous Thrombosis as Assessed by Magnetic Resonance Venography J. Bone Joint Surg. Am., November 12, 2002; 84(11): 1998 - 2004. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. SALVATI, V. D. PELLEGRINI, N. E. SHARROCK, P. A. LOTKE, D. W. MURRAY, H. POTTER, and G. H. WESTRICH Symposium - Recent Advances in Venous Thromboembolic Prophylaxis During and After Total Hip Replacement J. Bone Joint Surg. Am., February 1, 2000; 82(2): 252 - 70. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |