Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piplani, M. A.
Right arrow Articles by Cousins, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piplani, M. A.
Right arrow Articles by Cousins, J. P.

Radiology, Vol 198, 855-859, Copyright © 1996 by Radiological Society of North America


ARTICLES

Articular cartilage volume in the knee: semiautomated determination from three-dimensional reformations of MR images

MA Piplani, DG Disler, TR McCauley, TJ Holmes and JP Cousins
Department of Radiology, Albany Medical College, New York 12208, USA.

PURPOSE: To determine the accuracy of semiautomated quantification of articular cartilage volume from three-dimensional (3D) reformations of magnetic resonance (MR) images. MATERIALS AND METHODS: Sagittal, fat- suppressed, 3D, spoiled gradient-recalled-echo MR imaging of two bovine and two human cadaver knees was performed. Articular cartilage volume was calculated from 3D reformations of the MR images by using a semiautomated program written at the authors' institution. Calculated volumes were compared with directly measured volumes of the surgically removed articular cartilage. RESULTS: The percentage of error of the MR imaging-determined volumes was 6.53% +/- 4.75 (mean +/- standard deviation). A strong correlation between the two sets of observations was shown (r=.997). Linear regression showed the calculated volumes to be highly accurate (slope=1.002, P>.25). Repeated reformations yielded volumes that were reproducible (mean absolute error, 0.013 mL +/- 0.019) and not significantly different from the measured volume (P>.10). CONCLUSION: Semiautomated quantification of knee articular cartilage from MR images yields highly accurate cartilage volumes.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
D R Jeffrey and I Watt
Imaging hyaline cartilage
Br. J. Radiol., November 1, 2003; 76(911): 777 - 787.
[Full Text] [PDF]


Home page
Ann Rheum DisHome page
J-P Pelletier and J Martel-Pelletier
Therapeutic targets in osteoarthritis: from today to tomorrow with new imaging technology
Ann Rheum Dis, November 1, 2003; 62(90002): ii79 - 82.
[Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
T. R. McCauley and D. G. Disler
Magnetic Resonance Imaging of Articular Cartilage of the Knee
J. Am. Acad. Ortho. Surg., January 1, 2001; 9(1): 2 - 8.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
R. Muhlbauer, S. Lukasz, S. Faber, T. Stammberger, and F. Eckstein
Comparison of Knee Joint Cartilage Thickness in Triathletes and Physically Inactive Volunteers Based on Magnetic Resonance Imaging and Three-Dimensional Analysis
Am. J. Sports Med., July 1, 2000; 28(4): 541 - 546.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.