Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huda, W
Right arrow Articles by Palmer, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huda, W
Right arrow Articles by Palmer, C.

Radiology, Vol 199, 249-252, Copyright © 1996 by Radiological Society of North America


ARTICLES

Mottle on computed radiographs of the chest in pediatric patients

W Huda, RM Slone, CJ Belden, JL Williams, WA Cumming and CK Palmer
Department of Radiology, University of Florida College of Medicine, Gainesville 32610-0374, USA.

PURPOSE: To investigate the relationship between radiation exposure and perceived mottle at bedside pediatric chest examinations performed with screen-film and computed radiographic techniques. MATERIALS AND METHODS: In a pediatric intensive care unit, chest radiographs were obtained with both computed radiography (60 radiographs) and a 600- speed screen-film system (14 radiographs). The relative radiation exposure was estimated by using the sensitivity value obtained in the processing of each computed radiograph. Five radiologists assessed the mottle present in the computed radiographs and screen-film images. RESULTS: For computed radiographs, the perceived level of mottle was inversely related to radiation exposure. For the same radiation exposure, the perceived mottle on computed radiographs was significantly higher than that on screen-film images (P < .001 for small cassettes; P < .01 for large cassettes). CONCLUSION: Pediatric computed radiography of the chest requires approximately twice the exposure of a 600-speed screen-film system to attain the same level of mottle.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
S. Mazzocchi, G. Belli, S. Busoni, C. Gori, I. Menchi, P. Salucci, A. Taddeucci, and G. Zatelli
AEC set-up optimisation with computed radiography imaging
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 169 - 173.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Neofotistou, V. Tsapaki, S. Kottou, A. Schreiner-Karoussou, and E. Vano
Does digital imaging decrease patient dose? A pilot study and review of the literature
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. Huda, E. M. Scalzetti, and G. Levin
Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CT
Radiology, November 1, 2000; 217(2): 430 - 435.
[Abstract] [Full Text]