|
|
||||||||
Radiology, Vol 199, 37-40, Copyright © 1996 by Radiological Society of North America
ARTICLES |
CP Davis, ME Ladd, BJ Romanowski, S Wildermuth, JF Knoplioch and JF Debatin
Magnetic Resonance Imaging Center, Department of Radiology, University Hospital, Zurich, Switzerland.
PURPOSE: To determine the feasibility of use of magnetic resonance (MR) imaging data sets to perform virtual intraarterial endoscopy (VIE). MATERIALS AND METHODS: Seven female and 14 male patients (aged 9-86 years [mean, 42 years]) with various pathologic aortic conditions underwent three-dimensional gadolinium-enhanced spoiled gradient-echo MR imaging. With prototype software, VIE postprocessing algorithms (based on ray casting) were applied to the imaging data sets. Findings at conventional angiography were used as the standards of reference. RESULTS: The vessel wall was seen from the inside in each case, and the following pathologic conditions were depicted clearly: the two lumina in a congenial double aortic arch and the single lumen after correction, vessel narrowing in coarctations, characteristics of Leriche syndrome, stenoses, occlusions, and the true and false lumina of dissections. CONCLUSIONS: Limitations of VIE include the image quality of the original data set, the threshold chosen to minimize intraluminal artifacts, and the inherent smoothing of vessel walls.
This article has been cited by other articles:
![]() |
Q. Liu, J. P. Lu, F. Wang, L. Wang, and J. M. Tian Three-dimensional Contrast-enhanced MR Angiography of Aortic Dissection: A Pictorial Essay RadioGraphics, September 1, 2007; 27(5): 1311 - 1321. [Abstract] [Full Text] [PDF] |
||||
![]() |
N Rilinger, H Seifarth, R Sokiranski, S Kramer, F Liewald, J Goerich, A Tomzcak, and C E E Nierhoff Virtual intra-arterial angioscopy (VIA) of the carotid artery based on helical CT data Br. J. Radiol., November 1, 2003; 76(911): 792 - 797. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Glockner Navigating the Aorta: MR Virtual Vascular Endoscopy RadioGraphics, March 1, 2003; 23(2): e11 - e11. [Abstract] [Full Text] |
||||
![]() |
E. Neri, P. Boraschi, D. Caramella, L. Battolla, R. Gigoni, N. Armillotta, G. Braccini, and C. Bartolozzi MR Virtual Endoscopy of the Upper Urinary Tract Am. J. Roentgenol., December 1, 2000; 175(6): 1697 - 1702. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Nakanishi, M. Kohata, K. Miyasaka, H. Fukuoka, K. Ito, and M. Imazu Virtual Endoscopy of Coronary Arteries Using Contrast-Enhanced ECG-Triggered Electron Beam CT Data Sets Am. J. Roentgenol., May 1, 2000; 174(5): 1345 - 1347. [Full Text] [PDF] |
||||
![]() |
E. Neri, D. Caramella, F. Falaschi, P. Sbragia, C. Vignali, E. Laiolo, A. Viviani, and C. Bartolozzi Virtual CT Intravascular Endoscopy of the Aorta: Pierced Surface and Floating Shape Thresholding Artifacts Radiology, July 1, 1999; 212(1): 276 - 279. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |