Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Halpern, J.
Right arrow Articles by Trautlein, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Halpern, J.
Right arrow Articles by Trautlein, J.

Radiology, Vol 199, 359-362, Copyright © 1996 by Radiological Society of North America


ARTICLES

Patient allergies: role in selective use of nonionic contrast material

JD Halpern, KD Hopper, MG Arredondo and JJ Trautlein
College of Medicine, Pennsylvania State University, Hershey, PA 17033, USA.

PURPOSE: To determine which aspects of patient allergies allergists and immunologists would recommend for the selective use of nonionic contrast material. MATERIALS AND METHODS: A survey about allergy and the selective use of nonionic contrast material was sent to 1,017 allergists and immunologists. RESULTS: Of 287 respondents, 262 believed that a non-contrast material-related allergy alone was not an indication for use of nonionic contrast material. Most (n=219) believed that a previous serious or life-threatening reaction was the best indication and that a minor reaction was not an indication. Most respondents believed that patients with any previous reaction to contrast material should receive nonionic contrast material, steroids and then nonionic contrast material, or no contrast material at all. CONCLUSION: Use of nonionic contrast material in patients with previous non-contrast material-related allergic reactions should be limited to patients with previous serious or life-threatening reactions.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. S. Freed, R. A. Leder, C. Alexander, D. M. DeLong, and M. A. Kliewer
Breakthrough Adverse Reactions to Low-Osmolar Contrast Media After Steroid Premedication
Am. J. Roentgenol., June 1, 2001; 176(6): 1389 - 1392.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.