Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jezzard, P
Right arrow Articles by Balaban, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jezzard, P
Right arrow Articles by Balaban, R.

Radiology, Vol 199, 773-779, Copyright © 1996 by Radiological Society of North America


ARTICLES

MR relaxation times in human brain: measurement at 4 T

P Jezzard, S Duewell and RS Balaban
Laboratory of Cardiac Energetics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892-1061, USA.

PURPOSE: To determine the values for relaxation times in human brain for magnetic resonance (MR) imaging at 4 T. MATERIALS AND METHODS: T1 measurements were made with a progressive saturation sequence, an implementation of the Look-Locker sequence, and an inversion-recovery (IR) interleaved echo-planar imaging (IEPI) sequence. T2 measurements were made with a standard spin-echo (SE) sequence and an SE IEPI sequence. RESULTS: The T1 measurements yielded values of 1,724 msec +/- 51 for gray matter, 1,043 msec +/- 27 for white matter, and 4,550 msec +/- 800 msec for cerebrospinal fluid. The deep gray matter regions had T1 values of 1,458 +/- 38 (caudate nucleus) and 1,372 +/- 60 (putamen). The T2 measurements yielded results of 63 msec +/- 6.2 for gray matter and 49.8 msec +/- 2.2 for white matter. CONCLUSION: The T1 values measured at 4 T show a higher value than predicted from extrapolation at lower field strengths. The T2 measurements showed a slight decrease in values over those measured at lower-field strength. The gain in signal-to-noise ratio from the higher field strength may be substantially offset by these altered relaxation time values to a degree that is sequence dependent.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
C.H. Vite, S. Magnitsky, D. Aleman, P. O'Donnell, K. Cullen, W. Ding, S. Pickup, J.H. Wolfe, and H. Poptani
Apparent Diffusion Coefficient Reveals Gray and White Matter Disease, and T2 Mapping Detects White Matter Disease in the Brain in Feline Alpha-Mannosidosis
AJNR Am. J. Neuroradiol., February 1, 2008; 29(2): 308 - 313.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. S. Lee, E. M. Hecht, B. Taouli, Q. Chen, K. Prince, and N. Oesingmann
Body and Cardiovascular MR Imaging at 3.0 T
Radiology, September 1, 2007; 244(3): 692 - 705.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
E. De Vita, A. Bainbridge, J. L. Y. Cheong, C. Hagmann, R. Lombard, W. K. Chong, J. S. Wyatt, E. B. Cady, R. J. Ordidge, and N. J. Robertson
Magnetic Resonance Imaging of Neonatal Encephalopathy at 4.7 Tesla: Initial Experiences
Pediatrics, December 1, 2006; 118(6): e1812 - e1821.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L.-A. Williams, N. Gelman, P. A. Picot, D. S. Lee, J. R. Ewing, V. K. Han, and R. T. Thompson
Neonatal Brain: Regional Variability of in Vivo MR Imaging Relaxation Rates at 3.0 T--Initial Experience
Radiology, May 1, 2005; 235(2): 595 - 603.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. E. Gold, E. Han, J. Stainsby, G. Wright, J. Brittain, and C. Beaulieu
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Am. J. Roentgenol., August 1, 2004; 183(2): 343 - 351.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. M. J. de Bazelaire, G. D. Duhamel, N. M. Rofsky, and D. C. Alsop
MR Imaging Relaxation Times of Abdominal and Pelvic Tissues Measured in Vivo at 3.0 T: Preliminary Results
Radiology, March 1, 2004; 230(3): 652 - 659.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E De Vita, D L Thomas, S Roberts, H G Parkes, R Turner, P Kinchesh, K Shmueli, T A Yousry, and R J Ordidge
High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging
Br. J. Radiol., September 1, 2003; 76(909): 631 - 637.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
O. Gonen, S. Gruber, B. S. Y. Li, V. Mlynarik, and E. Moser
Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison
AJNR Am. J. Neuroradiol., October 1, 2001; 22(9): 1727 - 1731.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Gelman, J. M. Gorell, P. B. Barker, R. M. Savage, E. M. Spickler, J. P. Windham, and R. A. Knight
MR Imaging of Human Brain at 3.0 T: Preliminary Report on Transverse Relaxation Rates and Relation to Estimated Iron Content
Radiology, March 1, 1999; 210(3): 759 - 767.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.