Laboratory of Cardiac Energetics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892-1061, USA.
PURPOSE: To evaluate multiple magnetic resonance (MR) imaging sequences for their ability to provide T1 and T2-weighted images at a field strength of 4 T, and to validate previously obtained relaxation time measurements. MATERIALS AND METHODS: Different spin-echo, inversion- recovery (IR), gradient-recalled acquisition in the steady state (GRASS), and magnetization transfer contrast-enhanced GRASS sequences were evaluated in a single section, each in at least four volunteers. Also, interleaved echo-planar imaging (IEPI) and interleaved gradient- recalled echo (IGRE) sequences were analyzed and compared with standard sequences. RESULTS: Predicted contrast behavior, according to MR relaxation time measurements, was found to agree well with that of the validation experiments. Fair T1 contrast can be achieved on MR images at 4 T, contrary to early predictions. Under other conditions, however, such as partially spin-density-weighted parameters, lower contrast is observed at the high field strength when compared with conventional field strengths. CONCLUSION: The longer T1 values at higher field strengths have a substantial effect on image contrast. Depending on the sequence and parameters chosen, good image contrast can be realized at 4 T. IEPI and hybrid IR IGRE sequences are useful in shortening the prolonged examination times owing to the longer T1 values at higher field strengths.
This article has been cited by other articles:
![]() |
R.H. Tetzlaff, I. Mader, W. Kuker, J. Weber, S. Ziyeh, A. Schulze-Bonhage, J. Hennig, and M. Weigel Hyperecho-Turbo Spin-Echo Sequences at 3T: Clinical Application in Neuroradiology AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 956 - 961. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, E. M. Hecht, B. Taouli, Q. Chen, K. Prince, and N. Oesingmann Body and Cardiovascular MR Imaging at 3.0 T Radiology, September 1, 2007; 244(3): 692 - 705. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. J. de Bazelaire, G. D. Duhamel, N. M. Rofsky, and D. C. Alsop MR Imaging Relaxation Times of Abdominal and Pelvic Tissues Measured in Vivo at 3.0 T: Preliminary Results Radiology, March 1, 2004; 230(3): 652 - 659. [Abstract] [Full Text] [PDF] |
||||
![]() |
E De Vita, D L Thomas, S Roberts, H G Parkes, R Turner, P Kinchesh, K Shmueli, T A Yousry, and R J Ordidge High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging Br. J. Radiol., September 1, 2003; 76(909): 631 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Dousset, L. Ballarino, C. Delalande, M. Coussemacq, P. Canioni, K. G. Petry, and J.-M. Caillé Comparison of Ultrasmall Particles of Iron Oxide (USPIO)-Enhanced T2-Weighted, Conventional T2-Weighted, and Gadolinium-Enhanced T1-Weighted MR Images in Rats with Experimental Autoimmune Encephalomyelitis AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 223 - 227. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |