Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Duewell, S
Right arrow Articles by Jezzard, P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Duewell, S
Right arrow Articles by Jezzard, P

Radiology, Vol 199, 780-786, Copyright © 1996 by Radiological Society of North America


ARTICLES

MR imaging contrast in human brain tissue: assessment and optimization at 4 T

S Duewell, SD Wolff, H Wen, RS Balaban and P Jezzard
Laboratory of Cardiac Energetics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892-1061, USA.

PURPOSE: To evaluate multiple magnetic resonance (MR) imaging sequences for their ability to provide T1 and T2-weighted images at a field strength of 4 T, and to validate previously obtained relaxation time measurements. MATERIALS AND METHODS: Different spin-echo, inversion- recovery (IR), gradient-recalled acquisition in the steady state (GRASS), and magnetization transfer contrast-enhanced GRASS sequences were evaluated in a single section, each in at least four volunteers. Also, interleaved echo-planar imaging (IEPI) and interleaved gradient- recalled echo (IGRE) sequences were analyzed and compared with standard sequences. RESULTS: Predicted contrast behavior, according to MR relaxation time measurements, was found to agree well with that of the validation experiments. Fair T1 contrast can be achieved on MR images at 4 T, contrary to early predictions. Under other conditions, however, such as partially spin-density-weighted parameters, lower contrast is observed at the high field strength when compared with conventional field strengths. CONCLUSION: The longer T1 values at higher field strengths have a substantial effect on image contrast. Depending on the sequence and parameters chosen, good image contrast can be realized at 4 T. IEPI and hybrid IR IGRE sequences are useful in shortening the prolonged examination times owing to the longer T1 values at higher field strengths.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
R.H. Tetzlaff, I. Mader, W. Kuker, J. Weber, S. Ziyeh, A. Schulze-Bonhage, J. Hennig, and M. Weigel
Hyperecho-Turbo Spin-Echo Sequences at 3T: Clinical Application in Neuroradiology
AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 956 - 961.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. S. Lee, E. M. Hecht, B. Taouli, Q. Chen, K. Prince, and N. Oesingmann
Body and Cardiovascular MR Imaging at 3.0 T
Radiology, September 1, 2007; 244(3): 692 - 705.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. M. J. de Bazelaire, G. D. Duhamel, N. M. Rofsky, and D. C. Alsop
MR Imaging Relaxation Times of Abdominal and Pelvic Tissues Measured in Vivo at 3.0 T: Preliminary Results
Radiology, March 1, 2004; 230(3): 652 - 659.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E De Vita, D L Thomas, S Roberts, H G Parkes, R Turner, P Kinchesh, K Shmueli, T A Yousry, and R J Ordidge
High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging
Br. J. Radiol., September 1, 2003; 76(909): 631 - 637.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
V. Dousset, L. Ballarino, C. Delalande, M. Coussemacq, P. Canioni, K. G. Petry, and J.-M. Caillé
Comparison of Ultrasmall Particles of Iron Oxide (USPIO)-Enhanced T2-Weighted, Conventional T2-Weighted, and Gadolinium-Enhanced T1-Weighted MR Images in Rats with Experimental Autoimmune Encephalomyelitis
AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 223 - 227.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.