Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anzai, Y.
Right arrow Articles by Wahl, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anzai, Y.
Right arrow Articles by Wahl, R. L.

Radiology, Vol 200, 135-141, Copyright © 1996 by Radiological Society of North America


ARTICLES

Recurrence of head and neck cancer after surgery or irradiation: prospective comparison of 2-deoxy-2-[F-18]fluoro-D-glucose PET and MR imaging diagnoses

Y Anzai, WR Carroll, DJ Quint, CR Bradford, S Minoshima, GT Wolf and RL Wahl
Department of Radiology, University of Michigan Medical Center, University Hospital, Ann Arbor 48109-0028, USA.

PURPOSE: To evaluate the diagnostic accuracy of positron emission tomography (PET) with administration of 2-deoxy-2-[fluorine-18]fluoro-D- glucose (FDG) relative to that of magnetic resonance (MR) imaging and/or computed tomography (CT) in recurrent head and neck cancers. MATERIALS AND METHODS: Twelve adult patients (mean age, 63 years) with previously treated head and neck cancers and clinical suspicion of recurrence underwent FDG PET and MR imaging and/or CT. All images were blindly and independently interpreted without histopathologic findings (obtained within 1 week of imaging). The level of confidence in image interpretation was graded by using a five-point rating system (0 = definitely no recurrence to 4 = definite recurrence). RESULTS: Recurrence was confirmed in eight patients. With a rating of 4 as a positive finding, FDG PET yielded a sensitivity and specificity of 88% (seven of eight) and 100% (four of four), respectively; MR imaging and/or CT, 25% (two of eight) and 75% (three of four), respectively. Receiver-operating characteristic analysis showed significantly better diagnostic accuracy with FDG PET than with MR imaging and/or CT (area under curve = 0.96 vs 0.55, P < .03). CONCLUSION: These data indicate that PET metabolic imaging, as compared with anatomic methods, has improved diagnostic accuracy for recurrent head and neck cancer.


This article has been cited by other articles:


Home page
RadiologyHome page
M. Comoretto, L. Balestreri, E. Borsatti, M. Cimitan, G. Franchin, and M. Lise
Detection and Restaging of Residual and/or Recurrent Nasopharyngeal Carcinoma after Chemotherapy and Radiation Therapy: Comparison of MR Imaging and FDG PET/CT
Radiology, October 1, 2008; 249(1): 203 - 211.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. Y. Kim, S.-w. Lee, S. Y. Nam, K. C. Im, J.-S. Kim, S. J. Oh, S. D. Ahn, S. S. Shin, E. K. Choi, and J. H. Kim
The Feasibility of 18F-FDG PET Scans 1 Month After Completing Radiotherapy of Squamous Cell Carcinoma of the Head and Neck
J. Nucl. Med., March 1, 2007; 48(3): 373 - 378.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. M. Blodgett, C. C. Meltzer, and D. W. Townsend
PET/CT: Form and Function
Radiology, February 1, 2007; 242(2): 360 - 385.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. B. Fukui, T. M. Blodgett, C. H. Snyderman, J. J. Johnson, E. N. Myers, D. W. Townsend, and C. C. Meltzer
Combined PET-CT in the Head and Neck: Part 2. Diagnostic Uses and Pitfalls of Oncologic Imaging
RadioGraphics, July 1, 2005; 25(4): 913 - 930.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. F. Branstetter IV, T. M. Blodgett, L. A. Zimmer, C. H. Snyderman, J. T. Johnson, S. Raman, and C. C. Meltzer
Head and Neck Malignancy: Is PET/CT More Accurate than PET or CT Alone?
Radiology, May 1, 2005; 235(2): 580 - 586.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T.-C. Yen, J. T.-C. Chang, S.-H. Ng, Y.-C. Chang, S.-C. Chan, K.-J. Lin, W.-J. Lin, Y.-K. Fu, and C.-Y. Lin
The Value of 18F-FDG PET in the Detection of Stage M0 Carcinoma of the Nasopharynx
J. Nucl. Med., March 1, 2005; 46(3): 405 - 410.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. Kapoor, M. B. Fukui, and B. M. McCook
Role of 18FFDG PET/CT in the Treatment of Head and Neck Cancers: Posttherapy Evaluation and Pitfalls
Am. J. Roentgenol., February 1, 2005; 184(2): 589 - 597.
[Full Text] [PDF]


Home page
JNMHome page
N. Shu-Hang, J. C. Tung-Chieh, C. Sheng-Chieh, K. Sheung-Fat, W. Hung-Ming, L. Chun-Ta, C. Yu-Chen, W.-J. Lin, F. Ying-Kai, and Y. Tzu-Chen
Clinical Usefulness of 18F-FDG PET in Nasopharyngeal Carcinoma Patients with Questionable MRI Findings for Recurrence
J. Nucl. Med., October 1, 2004; 45(10): 1669 - 1676.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. K. Mukherji, I. M. Schmalfuss, J. Castelijns, and A. A. Mancuso
Clinical Applications of Tumor Volume Measurements for Predicting Outcome in Patients with Squamous Cell Carcinoma of the Upper Aerodigestive Tract
AJNR Am. J. Neuroradiol., September 1, 2004; 25(8): 1425 - 1432.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Schoder, H. W. D. Yeung, M. Gonen, D. Kraus, and S. M. Larson
Head and Neck Cancer: Clinical Usefulness and Accuracy of PET/CT Image Fusion
Radiology, April 1, 2004; 231(1): 65 - 72.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S-H Liu, J T Chang, S-H Ng, S-C Chan, and T-C Yen
False positive fluorine-18 fluorodeoxy-D-glucose positron emission tomography finding caused by osteoradionecrosis in a nasopharyngeal carcinoma patient
Br. J. Radiol., March 1, 2004; 77(915): 257 - 260.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. K. Mukherji and G. T. Wolf
Evaluation of Head and Neck Squamous Cell Carcinoma After Treatment
AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1743 - 1746.
[Full Text] [PDF]


Home page
JCOHome page
T.-C. Yen, K.-K. Ng, S.-Y. Ma, H.-H. Chou, C.-S. Tsai, S. Hsueh, T.-C. Chang, J.-H. Hong, L.-C. See, W.-J. Lin, et al.
Value of Dual-Phase 2-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography in Cervical Cancer
J. Clin. Oncol., October 1, 2003; 21(19): 3651 - 3658.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
G J R Cook
Nuclear medicine in imaging head and neck malignancies
Imaging, September 1, 2003; 15(3): 141 - 148.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
E. Chesnay, E. Babin, J. M. Constans, D. Agostini, A. Bequignon, A. Regeasse, F. Sobrio, and S. Moreau
Early Response to Chemotherapy in Hypopharyngeal Cancer: Assessment with 11C-Methionine PET, Correlation with Morphologic Response, and Clinical Outcome
J. Nucl. Med., April 1, 2003; 44(4): 526 - 532.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S.-Y. Ryu, M.-H. Kim, S.-C. Choi, C.-W. Choi, and K.-H. Lee
Detection of Early Recurrence with 18F-FDG PET in Patients with Cervical Cancer
J. Nucl. Med., March 1, 2003; 44(3): 347 - 352.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. Kostakoglu, H. Agress Jr, and S. J. Goldsmith
Clinical Role of FDG PET in Evaluation of Cancer Patients
RadioGraphics, March 1, 2003; 23(2): 315 - 340.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. S. Gambhir, J. Czernin, J. Schwimmer, D. H. S. Silverman, R. E. Coleman, and M. E. Phelps
A Tabulated Summary of the FDG PET Literature
J. Nucl. Med., May 1, 2001; 42(90050): 1S - 93.
[Full Text] [PDF]


Home page
JCOHome page
V. J. Lowe, J. H. Boyd, F. R. Dunphy, H. Kim, T. Dunleavy, B. T. Collins, D. Martin, B. C. Stack Jr, C. Hollenbeak, and J. W. Fletcher
Surveillance for Recurrent Head and Neck Cancer Using Positron Emission Tomography
J. Clin. Oncol., February 1, 2000; 18(3): 651 - 651.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
K. N. Ganjoo, R. J. Chan, M. Sharma, and L. H. Einhorn
Positron Emission Tomography Scans in the Evaluation of Postchemotherapy Residual Masses in Patients With Seminoma
J. Clin. Oncol., November 1, 1999; 17(11): 3457 - 3460.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. J. Lowe, H. Kim, J. H. Boyd, J. F. Eisenbeis, F. R. Dunphy, and J. W. Fletcher
Primary and Recurrent Early Stage Laryngeal Cancer: Preliminary Results of 2-[Fluorine 18]fluoro-2-deoxy-D-glucose PET Imaging
Radiology, September 1, 1999; 212(3): 799 - 802.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
S. K. Mukherji, M. Gapany, D. Phillips, B. Neelon, S. O' O'Brien, W. McCartney, S. Buejenovich, J. S. Parekh, J. P. Noordzij, and M. Castillo
Thallium-201 Single-Photon Emission CT versus CT for the Detection of Recurrent Squamous Cell Carcinoma of the Head and Neck
AJNR Am. J. Neuroradiol., August 1, 1999; 20(7): 1215 - 1220.
[Abstract] [Full Text]


Home page
RadiologyHome page
Y. Anzai, S. Minoshima, G. T. Wolf, and R. L. Wahl
Head and Neck Cancer: Detection of Recurrence with Three-dimensional Principal Components Analysis at Dynamic FDG PET
Radiology, July 1, 1999; 212(1): 285 - 290.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.