Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wagner, L. K.
Right arrow Articles by Mulhern, O. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wagner, L. K.
Right arrow Articles by Mulhern, O. R.

Radiology, Vol 200, 45-48, Copyright © 1996 by Radiological Society of North America


ARTICLES

Radiation-attenuating surgical gloves: effects of scatter and secondary electron production

LK Wagner and OR Mulhern
Department of Radiology, University of Texas Houston Medical School 77030, USA.

PURPOSE: To evaluate the effects of scatter and secondary electron production on the protection provided by flexible radiation-attenuating gloves. MATERIALS AND METHODS: Four sets of radiation-attenuating flexible gloves and one set of standard surgical gloves were tested for scattering characteristics and secondary electron production caused by the interactions of x rays inside the gloves. A thin-window ion chamber was used to measure the penetration of secondary electrons in polyethylene. A diagnostic-type chamber was used to measure forward- scattered and backscattered x rays produced by the gloves. RESULTS: Forward-scattered and backscattered x rays added an average of about 13% to the exposure of the hands. Secondary electrons increased the signal in the thin-window chamber by large factors but were weakly penetrating, and only a small fraction produced by x rays of 90 kVp and higher energies contributed to dose to basal cells. CONCLUSION: Forward- scattered and backscattered x rays reduce the effectiveness of radiation-attenuating gloves, and secondary electron dose to basal cells in the back of the hand can further reduce effectiveness.


This article has been cited by other articles:


Home page
J Am Acad Orthop SurgHome page
G. Singer
Occupational Radiation Exposure to the Surgeon
J. Am. Acad. Ortho. Surg., January 1, 2005; 13(1): 69 - 76.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
C. Tsopelas, P. J. Collins, and C. Blefari
A Simple and Effective Technique to Reduce Staff Exposure During the Preparation of Radiopharmaceuticals
J. Nucl. Med. Technol., March 1, 2003; 31(1): 37 - 40.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. N. King, A. M. Champlin, C. A. Kelsey, and D. A. Tripp
Using a Sterile Disposable Protective Surgical Drape for Reduction of Radiation Exposure to Interventionalists
Am. J. Roentgenol., January 1, 2002; 178(1): 153 - 157.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.