Radiology, Vol 200, 59-67, Copyright © 1996 by Radiological Society of North America
ARTICLES |
TJ Vogl, S Kummel, R Hammerstingl, M Schellenbeck, G Schumacher, T Balzer, W Schwarz, PK Muller, WO Bechstein, MG Mack, O Sollner and R Felix
Department of Radiology, Humboldt-University of Berlin, Rudolf Virchow Hospital, Germany.
PURPOSE: To compare the usefulness of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) in the diagnosis of focal liver lesions. MATERIALS AND METHODS: Thirty-one patients with focal liver lesions underwent T2- and T1-weighted spin-echo magnetic resonance (MR) imaging and fast low-angle shot two-dimensional MR imaging before, during, and after intravenous administration of three different doses of Gd-EOB-DTPA (12.5, 25, and 50 mumol per kilogram body weight). Gd-DTPA-enhanced imaging (dose, 0.1 mmol per kilogram body weight) was performed in the same patients within 1 week of Gd-EOB- DTPA imaging. RESULTS: During the perfusion phase (the 3 minutes after injection of contrast material), the dynamic enhancement characteristics seen after injection of 25 and 50 mumol of Gd-EOB-DTPA were similar to those seen with Gd-DTPA. At the lowest dose of Gd-EOB- DTPA (12.5 mumol), the dynamic enhancement characteristics were not comparable to those seen with Gd-DTPA. During the hepatobiliary phase (1.5 minutes to 4 hours after injection), Gd-EOB-DTPA-enhanced images yielded a dose-independent, statistically significant improvement in the detection rate of additional metastases, hepatocellular carcinomas, and hemangiomas compared with unenhanced and Gd-DTPA-enhanced images (P < .05). CONCLUSION: Gd-EOB-DTPA-enhanced MR imaging enables improved detection of hepatic lesions over Gd-DTPA-enhanced MR imaging while providing comparable differential diagnostic information.
This article has been cited by other articles:
![]() |
D. A. Bluemke, D. Sahani, M. Amendola, T. Balzer, J. Breuer, J. J. Brown, D. D. Casalino, P. L. Davis, I. R. Francis, G. Krinsky, et al. Efficacy and Safety of MR Imaging with Liver-specific Contrast Agent: U.S. Multicenter Phase III Study Radiology, October 1, 2005; 237(1): 89 - 98. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Huppertz, S. Haraida, A. Kraus, C. J. Zech, J. Scheidler, J. Breuer, T. K. Helmberger, and M. F. Reiser Enhancement of Focal Liver Lesions at Gadoxetic Acid-enhanced MR Imaging: Correlation with Histopathologic Findings and Spiral CT--Initial Observations Radiology, February 1, 2005; 234(2): 468 - 478. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Huppertz, T. Balzer, A. Blakeborough, J. Breuer, A. Giovagnoni, G. Heinz-Peer, M. Laniado, R. M. Manfredi, D. G. Mathieu, D. Mueller, et al. Improved Detection of Focal Liver Lesions at MR Imaging: Multicenter Comparison of Gadoxetic Acid-enhanced MR Images with Intraoperative Findings Radiology, January 1, 2004; 230(1): 266 - 275. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Matsuo, M. Kanematsu, K. Itoh, K. Ito, Y. Maetani, H. Kondo, N. Kako, N. Matsunaga, H. Hoshi, and J. Shiraishi Detection of Malignant Hepatic Tumors: Comparison of Gadolinium-and Ferumoxide-Enhanced MR Imaging Am. J. Roentgenol., September 1, 2001; 177(3): 637 - 643. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kobayashi, T. Saga, S. Kawamoto, N. Sato, A. Hiraga, T. Ishimori, J. Konishi, K. Togashi, and M. W. Brechbiel Dynamic Micro-Magnetic Resonance Imaging of Liver Micrometastasis in Mice with a Novel Liver Macromolecular Magnetic Resonance Contrast Agent DAB-Am64-(1B4M-Gd)64 Cancer Res., July 1, 2001; 61(13): 4966 - 4970. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Semelka and T. K. G. Helmberger Contrast Agents for MR Imaging of the Liver Radiology, January 1, 2001; 218(1): 27 - 38. [Abstract] [Full Text] |
||||
![]() |
H. Kondo, M. Kanematsu, H. Hoshi, T. Murakami, T. Kim, M. Hori, M. Matsuo, and H. Nakamura Preoperative Detection of Malignant Hepatic Tumors: Comparison of Combined Methods of MR Imaging with Combined Methods of CT Am. J. Roentgenol., April 1, 2000; 174(4): 947 - 954. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. T. Sica, H. Ji, and P. R. Ros CT and MR Imaging of Hepatic Metastases Am. J. Roentgenol., March 1, 2000; 174(3): 691 - 698. [Full Text] [PDF] |
||||
![]() |
J. E. van Montfoort, B. Stieger, D. K. F. Meijer, H.-J. Weinmann, P. J. Meier, and K. E. Fattinger Hepatic Uptake of the Magnetic Resonance Imaging Contrast Agent Gadoxetate by the Organic Anion Transporting Polypeptide Oatp1 J. Pharmacol. Exp. Ther., July 1, 1999; 290(1): 153 - 157. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |