Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vogl, T. J.
Right arrow Articles by Felix, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vogl, T. J.
Right arrow Articles by Felix, R.

Radiology, Vol 200, 59-67, Copyright © 1996 by Radiological Society of North America


ARTICLES

Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA

TJ Vogl, S Kummel, R Hammerstingl, M Schellenbeck, G Schumacher, T Balzer, W Schwarz, PK Muller, WO Bechstein, MG Mack, O Sollner and R Felix
Department of Radiology, Humboldt-University of Berlin, Rudolf Virchow Hospital, Germany.

PURPOSE: To compare the usefulness of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) in the diagnosis of focal liver lesions. MATERIALS AND METHODS: Thirty-one patients with focal liver lesions underwent T2- and T1-weighted spin-echo magnetic resonance (MR) imaging and fast low-angle shot two-dimensional MR imaging before, during, and after intravenous administration of three different doses of Gd-EOB-DTPA (12.5, 25, and 50 mumol per kilogram body weight). Gd-DTPA-enhanced imaging (dose, 0.1 mmol per kilogram body weight) was performed in the same patients within 1 week of Gd-EOB- DTPA imaging. RESULTS: During the perfusion phase (the 3 minutes after injection of contrast material), the dynamic enhancement characteristics seen after injection of 25 and 50 mumol of Gd-EOB-DTPA were similar to those seen with Gd-DTPA. At the lowest dose of Gd-EOB- DTPA (12.5 mumol), the dynamic enhancement characteristics were not comparable to those seen with Gd-DTPA. During the hepatobiliary phase (1.5 minutes to 4 hours after injection), Gd-EOB-DTPA-enhanced images yielded a dose-independent, statistically significant improvement in the detection rate of additional metastases, hepatocellular carcinomas, and hemangiomas compared with unenhanced and Gd-DTPA-enhanced images (P < .05). CONCLUSION: Gd-EOB-DTPA-enhanced MR imaging enables improved detection of hepatic lesions over Gd-DTPA-enhanced MR imaging while providing comparable differential diagnostic information.


This article has been cited by other articles:


Home page
RadiologyHome page
D. A. Bluemke, D. Sahani, M. Amendola, T. Balzer, J. Breuer, J. J. Brown, D. D. Casalino, P. L. Davis, I. R. Francis, G. Krinsky, et al.
Efficacy and Safety of MR Imaging with Liver-specific Contrast Agent: U.S. Multicenter Phase III Study
Radiology, October 1, 2005; 237(1): 89 - 98.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Huppertz, S. Haraida, A. Kraus, C. J. Zech, J. Scheidler, J. Breuer, T. K. Helmberger, and M. F. Reiser
Enhancement of Focal Liver Lesions at Gadoxetic Acid-enhanced MR Imaging: Correlation with Histopathologic Findings and Spiral CT--Initial Observations
Radiology, February 1, 2005; 234(2): 468 - 478.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Huppertz, T. Balzer, A. Blakeborough, J. Breuer, A. Giovagnoni, G. Heinz-Peer, M. Laniado, R. M. Manfredi, D. G. Mathieu, D. Mueller, et al.
Improved Detection of Focal Liver Lesions at MR Imaging: Multicenter Comparison of Gadoxetic Acid-enhanced MR Images with Intraoperative Findings
Radiology, January 1, 2004; 230(1): 266 - 275.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Matsuo, M. Kanematsu, K. Itoh, K. Ito, Y. Maetani, H. Kondo, N. Kako, N. Matsunaga, H. Hoshi, and J. Shiraishi
Detection of Malignant Hepatic Tumors: Comparison of Gadolinium-and Ferumoxide-Enhanced MR Imaging
Am. J. Roentgenol., September 1, 2001; 177(3): 637 - 643.
[Abstract] [Full Text] [PDF]


Home page
Cancer Res.Home page
H. Kobayashi, T. Saga, S. Kawamoto, N. Sato, A. Hiraga, T. Ishimori, J. Konishi, K. Togashi, and M. W. Brechbiel
Dynamic Micro-Magnetic Resonance Imaging of Liver Micrometastasis in Mice with a Novel Liver Macromolecular Magnetic Resonance Contrast Agent DAB-Am64-(1B4M-Gd)64
Cancer Res., July 1, 2001; 61(13): 4966 - 4970.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. C. Semelka and T. K. G. Helmberger
Contrast Agents for MR Imaging of the Liver
Radiology, January 1, 2001; 218(1): 27 - 38.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
H. Kondo, M. Kanematsu, H. Hoshi, T. Murakami, T. Kim, M. Hori, M. Matsuo, and H. Nakamura
Preoperative Detection of Malignant Hepatic Tumors: Comparison of Combined Methods of MR Imaging with Combined Methods of CT
Am. J. Roentgenol., April 1, 2000; 174(4): 947 - 954.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. T. Sica, H. Ji, and P. R. Ros
CT and MR Imaging of Hepatic Metastases
Am. J. Roentgenol., March 1, 2000; 174(3): 691 - 698.
[Full Text] [PDF]


Home page
J. Pharmacol. Exp. Ther.Home page
J. E. van Montfoort, B. Stieger, D. K. F. Meijer, H.-J. Weinmann, P. J. Meier, and K. E. Fattinger
Hepatic Uptake of the Magnetic Resonance Imaging Contrast Agent Gadoxetate by the Organic Anion Transporting Polypeptide Oatp1
J. Pharmacol. Exp. Ther., July 1, 1999; 290(1): 153 - 157.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.