Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Link, J.
Right arrow Articles by Heller, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Link, J.
Right arrow Articles by Heller, M.

Radiology, Vol 200, 397-401, Copyright © 1996 by Radiological Society of North America


ARTICLES

Dacron-covered stent-grafts for the percutaneous treatment of carotid aneurysms: effectiveness and biocompatibility--experimental study in swine

J Link, B Feyerabend, M Grabener, U Linstedt, J Brossmann, H Thomsen and M Heller
Department of Radiology, Christian-Albrechts-University of Kiel, Germany.

PURPOSE: To evaluate the short-term effectiveness and biocompatibility of Dacron-covered stent-grafts for percutaneous treatment of carotid aneurysms. MATERIALS AND METHODS: In eight swine, nine aneurysms were created surgically in the common carotid artery. Percutaneous treatment was performed with Dacron-covered stent-grafts. Seven of eight swine underwent follow-up angiography at 2, 3, 4, and 5 weeks after stent implantation. Histologic examinations of tissue from the site of stent implantation were performed at the same intervals. RESULTS: Initial closing off of the aneurysm was possible in all swine. Angiographic follow-up revealed patency of only one Dacron-covered stent-graft after 2 weeks. In six of seven swine, the stent was occluded on the follow-up angiogram. One of the swine died of unclear cause after 1 week. The stent-graft of this swine was not occluded. In all Dacron-covered stent- grafts, inflammatory reaction with granulocyte infiltration was found next to the Dacron material. CONCLUSION: Primary treatment of carotid aneurysms with Dacron-covered stent-grafts is effective. However, the short-term patency rate is poor, which probably can be attributed to the limited biocompatibility of the Dacron cover. An acute inflammatory reaction against Dacron seems responsible for the poor patency rate.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
E. Archondakis, G. Pero, L. Valvassori, E. Boccardi, and G. Scialfa
Angiographic Follow-Up of Traumatic Carotid Cavernous Fistulas Treated with Endovascular Stent Graft Placement
AJNR Am. J. Neuroradiol., February 1, 2007; 28(2): 342 - 347.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y.-C. Weon, S.-G. Kang, J. W. Chung, Y. I. Kim, J. H. Park, and D. Y. Lee
Technical feasibility and biocompatibility of a newly designed separating stent-graft in the normal canine aorta.
Am. J. Roentgenol., April 1, 2006; 186(4): 1148 - 1154.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
J. F.W. Keuren, S. J.H. Wielders, A. Driessen, M. Verhoeven, M. Hendriks, and T. Lindhout
Covalently-Bound Heparin Makes Collagen Thromboresistant
Arterioscler. Thromb. Vasc. Biol., March 1, 2004; 24(3): 613 - 617.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
B. Mehta, T. Burke, M. Kole, A. Bydon, D. Seyfried, and G. Malik
Stent-within-a-Stent Technique for the Treatment of Dissecting Vertebral Artery Aneurysms
AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1814 - 1818.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. J. Cloft, D. F. Kallmes, H.-B. Lin, S.-T. Li, W. F. Marx, S. B. Hudson, G. A. Helm, M. B. Lopes, J. K. McGraw, J. E. Dion, et al.
Bovine Type I Collagen as an Endovascular Stent-Graft Material: Biocompatibility Study in Rabbits
Radiology, February 1, 2000; 214(2): 557 - 562.
[Abstract] [Full Text]


Home page
VASC ENDOVASCULAR SURGHome page
P. Szopinski, J. Iwanowski, M. Kielar, and W. Noszczyk
Posttraumatic Pseudoaneurysm of Stenotic Internal Carotid Artery Repair by Stent Graft: A Case Report
Vascular and Endovascular Surgery, January 1, 2000; 34(1): 81 - 85.
[Abstract] [PDF]


Home page
RadiologyHome page
T. Sakai, M. D. Dake, C. P. Semba, T. Yamada, A. Arakawa, S. T. Kee, N. Hayashi, M. K. Razavi, and D. Y. Sze
Descending Thoracic Aortic Aneurysm: Thoracic CT Findings after Endovascular Stent-Graft Placement
Radiology, July 1, 1999; 212(1): 169 - 174.
[Abstract] [Full Text]


Home page
RadiologyHome page
F. Schellhammer, M. Walter, A. Berlis, H.-G. Bloss, E. Wellens, and M. Schumacher
Polyethylene Terephthalate and Polyurethane Coatings for Endovascular Stents: Preliminary Results in Canine Experimental Arteriovenous Fistulas
Radiology, April 1, 1999; 211(1): 169 - 175.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.