Radiology, Vol 201, 279-282, Copyright © 1996 by Radiological Society of North America
ARTICLES |
ME Delclos, R Komaki, RC Morice, PK Allen, M Davis and A Garden
Department of radiotherapy, University of Texas, M.D. Anderson Cancer Center, Houston, TX 77030, USA.
PURPOSE: To evaluate toxicity and efficacy of endobronchial brachytherapy with high-dose-rate (HDR) after-loading of iridium-192 for recurrent endobronchial lesions. MATERIALS AND METHODS: From 1988 to 1993, 81 patients with lung cancer previously treated with external beam radiation therapy were treated with palliative HDR endobronchial brachytherapy for symptoms due to relapse or persistent tumor of endobronchial bronchogenic origin. For most patients, Ir-192 was delivered in a dose of 3,000 cGy at 6 mm in two fractions over 2 weeks. RESULTS: Sixty-eight patients (84%) achieved some response: Twenty-six (32%) had excellent, 25 (31%) had moderate, and 17 (21%) had minimal symptomatic improvement with HDR endobronchial brachytherapy. Eleven patients had no change, and two became worse. The median duration of responses was 4.5 months. Those patients with an excellent response had a significantly better survival (13.3 months) compared with that of the other patients (5.4 months) (P = .01). There were two fatal complications, which were due to fistula and tracheal malacia. CONCLUSION: HDR endobronchial brachytherapy is an effective method to relieve airway obstruction promptly for patients with recurrent endobronchial lesions and may be considered as a boost for obstructive lesions before chemotherapy and external beam radiation therapy.
This article has been cited by other articles:
![]() |
N. Fuwa, T. Kodaira, H. Tachibana, T. Nakamura, N. Tomita, and T. Daimon Long-term Observation of 64 Patients with Roentgenographically Occult Lung Cancer Treated with External Irradiation and Intraluminal Irradiation Using Low-dose-rate Iridium Jpn. J. Clin. Oncol., September 1, 2008; 38(9): 581 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Kishi, T Yoshimasu, S Shirai, Y Minakata, M Kimura, T Sonomura, Y Shioyama, and M Sato Usefulness of mini-tracheostomy and torque controlled insertion of applicator in fractionated endobronchial brachytherapy. Br. J. Radiol., June 1, 2006; 79(942): 522 - 527. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ernst, D. Feller-Kopman, H. D. Becker, and A. C. Mehta Central Airway Obstruction Am. J. Respir. Crit. Care Med., June 15, 2004; 169(12): 1278 - 1297. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Morice, T. Ece, F. Ece, and L. Keus Endobronchial Argon Plasma Coagulation for Treatment of Hemoptysis and Neoplastic Airway Obstruction Chest, March 1, 2001; 119(3): 781 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Tanaka, T. Abe, K. Kojima, H. Nishimura, and N. Hayabuchi Applicability and Advantages of Flow artifact-insensitive Fluid-attenuated Inversion-recovery MR Sequences for Imaging the Posterior Fossa AJNR Am. J. Neuroradiol., June 1, 2000; 21(6): 1095 - 1098. [Abstract] [Full Text] |
||||
![]() |
V. P. Mathews, K. S. Caldemeyer, M. J. Lowe, S. L. Greenspan, D. M. Weber, and J. L. Ulmer Brain: Gadolinium-enhanced Fast Fluid-attenuated Inversion-Recovery MR Imaging Radiology, April 1, 1999; 211(1): 257 - 263. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |