|
|
||||||||
Radiology, Vol 201, 45-50, Copyright © 1996 by Radiological Society of North America
ARTICLES |
CM Schaefer-Prokop, M Prokop, A Schmidt, U Neitzel and M Galanski
Department of Diagnostic Radiology, Hannover Medical School, Germany.
PURPOSE: To compare selenium detectors with three conventional and digital detector systems for the detection of simulated pulmonary lesions. MATERIALS AND METHODS: Templates containing nodules, linear structures, and micronodular opacities were superimposed over an anthropomorphic chest phantom. The authors compared lesion detection with use of storage phosphor radiography (250 speed), selenium radiography (250 speed) with an antiscatter grid, selenium radiography (450 speed) without an antiscatter grid, an asymmetric screen-film system (400 speed), and a conventional screen-film system (250 speed). Detection performance of 10 radiologists was compared by using a multireader-multicase receiver operating characteristic analysis of variance. RESULTS: For the detection of nodules, no statistically significant differences between imaging modes were seen. For the detection of micronodules and linear lesions, both selenium techniques were superior to all other modes (P < .05). In addition, the asymmetric screen-film radiographs were inferior (P < .05) to the conventional screen-film radiographs and to storage phosphor radiographs for the detection of micronodules. CONCLUSION: The selenium detector improves detection of simulated fine linear and low-contrast micronodular details and appears to be superior to other detector systems for chest radiography.
This article has been cited by other articles:
![]() |
C S Moore, G P Liney, A W Beavis, and J R Saunderson A method to optimize the processing algorithm of a computed radiography system for chest radiography Br. J. Radiol., September 1, 2007; 80(957): 724 - 730. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, J. P. A. van Delft, and J. Geleijns Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography. Radiology, November 1, 2006; 241(2): 392 - 398. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Bacher, P. Smeets, L. Vereecken, A. De Hauwere, P. Duyck, R. De Man, K. Verstraete, and H. Thierens Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems. Am. J. Roentgenol., September 1, 2006; 187(3): 630 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Ono, T Yoshitake, K Akahane, Y Yamada, T Maeda, M Kai, and T Kusama Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinoma lesions using hard copy images Br. J. Radiol., October 1, 2005; 78(934): 922 - 927. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, M. V. Boot, and J. Geleijns Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease Am. J. Roentgenol., August 1, 2005; 185(2): 339 - 346. [Abstract] [Full Text] [PDF] |
||||
![]() |
I D Honey, A Mackenzie, and D S Evans Investigation of optimum energies for chest imaging using film-screen and computed radiography Br. J. Radiol., May 1, 2005; 78(929): 422 - 427. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Metz, P. Damoser, R. Hollweck, R. Roggel, C. Engelke, K. Woertler, B. Renger, E. J. Rummeny, and T. M. Link Chest Radiography with a Digital Flat-Panel Detector: Experimental Receiver Operating Characteristic Analysis Radiology, March 1, 2005; 234(3): 776 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. M. Kroft, J. Geleijns, B. J. A. Mertens, W. J. H. Veldkamp, H. M. Zonderland, and A. de Roos Digital Slot-Scan Charge-coupled Device Radiography versus AMBER and Bucky Screen-Film Radiography for Detection of Simulated Nodules and Interstitial Disease in a Chest Phantom Radiology, April 1, 2004; 231(1): 156 - 163. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, H. J. Lee, M. J. Chung, J. B. Seo, H. Y. Kim, Y.-J. Lee, J.-W. Kang, and J. H. Kim Detection of Simulated Chest Lesions by Using Soft-Copy Reading: Comparison of an Amorphous Silicon Flat-Panel-Detector System and a Storage-Phosphor System Radiology, July 1, 2002; 224(1): 242 - 246. [Abstract] [Full Text] |
||||
![]() |
T. S. Kim, J.-G. Im, J. M. Goo, K. H. Lee, Y.-J. Lee, S. H. Kim, and S. Kim Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography Radiology, June 1, 2002; 223(3): 695 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, M. Komi, and S. Hori Selenium-Based Digital Radiography Versus High-Resolution Storage Phosphor Radiography in the Detection of Solitary Pulmonary Nodules Without Calcification: Receiver Operating Characteristic Curve Analysis Am. J. Roentgenol., November 1, 2001; 177(5): 1141 - 1144. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ludwig, T. M. Link, M. Fiebich, B. Renger, S. Diederich, M. Oelerich, H. Lenzen, and W. Heindel Selenium-based Digital Radiography in the Detection of Bone Lesions: Preliminary Experience with Experimentally Created Defects Radiology, July 1, 2000; 216(1): 220 - 224. [Abstract] [Full Text] |
||||
![]() |
M. Garmer, S. P. Hennigs, H. J. Jager, F. Schrick, T. van de Loo, A. Jacobs, A. Hanusch, A. Christmann, and K. Mathias Digital Radiography Versus Conventional Radiography in Chest Imaging: Diagnostic Performance of a Large-Area Silicon Flat-Panel Detector in a Clinical CT-Controlled Study Am. J. Roentgenol., January 1, 2000; 174(1): 75 - 80. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Bernhardt, D. Otto, G. Reichel, K. Ludwig, S. Seifert, S. Kropf, and U. Rapp-Bernhardt Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based Radiography Radiology, November 1, 1999; 213(2): 445 - 454. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |