Radiology, Vol 201, 51-60, Copyright © 1996 by Radiological Society of North America
ARTICLES |
T Ishigaki, T Endo, M Ikeda, M Kono, S Yoshida, J Ikezoe, K Murata and M Matsumoto
Department of Radiology, Nagoya University School of Medicine, Japan.
PURPOSE: To determine the diagnostic efficacy of hard- and soft-copy computed radiographic (CR) images versus conventional screen-film images of the chest in the detection of subtle pulmonary abnormalities. MATERIALS AND METHODS: Twenty observes compared 87 hard-copy and soft- copy CR images with hard-copy screen-film images. Of 87 test images, 45 (including two identical sets of 12 images to test intra-observer variability) were abnormal and 42 (including two identical sets of 12 images) were normal. Of the 45 abnormal images, 15 (including two sets of four identical images) showed subtle abnormalities, 15 (including two sets of four identical images) showed mild abnormalities, and 15 (including two sets of four identical images) showed obvious abnormalities. Soft-copy viewing provided three differently processed images of every radiograph. RESULTS: No statistically significant differences in receiver operating characteristic analyses were found among hard-copy screen-film images, hard-copy CR images, and soft-copy CR images, even in the group with subtle interstitial abnormalities. CONCLUSION: Hard-copy and soft-copy chest CR images are acceptable and available in place of screen-film images for primary interpretation of subtle interstitial lung diseases.
This article has been cited by other articles:
![]() |
N Buls, W Shabana, P Verbeek, P Pevenage, and J De Mey Influence of display quality on radiologists' performance in the detection of lung nodules on radiographs Br. J. Radiol., September 1, 2007; 80(957): 738 - 743. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Karlik Visualizing Radiologic Data Am. J. Roentgenol., March 1, 2003; 180(3): 607 - 619. [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, H. J. Lee, M. J. Chung, J. B. Seo, H. Y. Kim, Y.-J. Lee, J.-W. Kang, and J. H. Kim Detection of Simulated Chest Lesions by Using Soft-Copy Reading: Comparison of an Amorphous Silicon Flat-Panel-Detector System and a Storage-Phosphor System Radiology, July 1, 2002; 224(1): 242 - 246. [Abstract] [Full Text] |
||||
![]() |
T. S. Kim, J.-G. Im, J. M. Goo, K. H. Lee, Y.-J. Lee, S. H. Kim, and S. Kim Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography Radiology, June 1, 2002; 223(3): 695 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Y. Kim, K. S. Cho, K.-S. Song, J. H. Kim, J.-G. Kim, and H. K. Ha Urinary Calculi on Computed Radiography: Comparison of Observer Performance with Hard-Copy Versus Soft-Copy Images on Different Viewer Systems Am. J. Roentgenol., August 1, 2001; 177(2): 331 - 335. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P. M. Miró, A. N. Leung, G. D. Rubin, Y. H. Choi, S. T. Kee, R. E. Mindelzun, P. Stark, L. Wexler, S. K. Plevritis, and B. J. Betts Digital Storage Phosphor Chest Radiography: An ROC Study of the Effect of 2K versus 4K Matrix Size on Observer Performance Radiology, February 1, 2001; 218(2): 527 - 532. [Abstract] [Full Text] |
||||
![]() |
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Iinuma, K. Ushio, T. Ishikawa, S. Nawano, R. Sekiguchi, and M. Satake Diagnosis of Gastric Cancers: Comparison of Conventional Radiography and Digital Radiography with a 4 Million-Pixel Charge-coupled Device Radiology, February 1, 2000; 214(2): 497 - 502. [Abstract] [Full Text] |
||||
![]() |
M. Garmer, S. P. Hennigs, H. J. Jager, F. Schrick, T. van de Loo, A. Jacobs, A. Hanusch, A. Christmann, and K. Mathias Digital Radiography Versus Conventional Radiography in Chest Imaging: Diagnostic Performance of a Large-Area Silicon Flat-Panel Detector in a Clinical CT-Controlled Study Am. J. Roentgenol., January 1, 2000; 174(1): 75 - 80. [Abstract] [Full Text] [PDF] |
||||