Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Earls, J. P.
Right arrow Articles by Weinreb, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Earls, J. P.
Right arrow Articles by Weinreb, J. C.

Radiology, Vol 201, 705-710, Copyright © 1996 by Radiological Society of North America


ARTICLES

Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector

JP Earls, NM Rofsky, DR DeCorato, GA Krinsky and JC Weinreb
Department of Radiology, New York University Medical Center, NY 10016, USA.

PURPOSE: To determine the usefulness of a timing examination performed with 1 mL gadopentetate dimeglumine administered with a magnetic resonance (MR) power injector at single-dose three-dimensional (3D) MR aortography. MATERIALS AND METHODS: 3D fast imaging with steady-state precession (repetition time [msec]/echo time [msec] = 5.0/2.0, with 50 degrees flip angle) was performed in 30 patients after administration of 0.1 mmol/kg gadopentetate dimeglumine. In 15 inpatients, a power injector was used and a timing examination was performed (experimental group). In 15 outpatients, manual injection was used and a timing examination was not performed (control group). In the timing examination, 1 mL gadopentetate dimeglumine was followed with 15 mL saline, both at 2 mL/sec, during axial turbo fast low-angle shot imaging (11/4.2/300 [inversion time msec], with a 15 degrees flip angle); one image was obtained every 2 seconds for 60 seconds. Aortic signal-to-noise ratios (S/Ns) and contrast-to-noise ratios (C/Ns) were determined on images obtained in the two groups. RESULTS: In the timing examinations, aortic S/N increased significantly (902% +/- 517 [P < .001]) and was sufficient to help determine the timing of arterial enhancement. Findings on experimental images were superior to those on control images (S/N, 29.8 vs 20.5 [P = .003]; C/N, 23.8 vs 12.8 [P < .001], respectively). The time to perform procedures and calculations at the timing examination added a mean of 4.5 minutes to each examination. CONCLUSION: The combined use of a power injector and a timing examination improved S/Ns and C/Ns at breath-hold single-dose gadolinium-enhanced 3D MR aortography.


This article has been cited by other articles:


Home page
EuropaceHome page
T. H. Hauser, D. C. Peters, J. V. Wylie, and W. J. Manning
Evaluating the left atrium by magnetic resonance imaging
Europace, November 1, 2008; 10(suppl_3): iii22 - iii27.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. A. Schmidt and R. Morgan
Renal Contrast-enhanced MR Angiography: Timing Errors and Accurate Depiction of Renal Artery Origins
Radiology, October 1, 2008; 249(1): 178 - 186.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Miyazaki and V. S. Lee
Nonenhanced MR Angiography
Radiology, July 1, 2008; 248(1): 20 - 43.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh
Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging
Radiology, December 1, 2007; 245(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
C W Ryu, D H Lee, H S Kim, J H Lee, C G Choi, S J Kim, and D C Suh
Acquisition of MR perfusion images and contrast-enhanced MR angiography in acute ischaemic stroke patients: which procedure should be done first?
Br. J. Radiol., December 1, 2006; 79(948): 962 - 967.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. K. An, J. M. Lee, K.-S. Suh, N. J. Lee, S. H. Kim, Y. J. Kim, J. K. Han, and B. I. Choi
Gadobenate dimeglumine-enhanced liver MRI as the sole preoperative imaging technique: a prospective study of living liver donors.
Am. J. Roentgenol., November 1, 2006; 187(5): 1223 - 1233.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Finn, R. Saleh, S. Thesen, S. G. Ruehm, M. H. Lee, J. Grinstead, J. S. Child, and G. Laub
MR Imaging with Remote Control: Feasibility Study in Cardiovascular Disease
Radiology, November 1, 2006; 241(2): 528 - 537.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J.-S. Yu and N. M. Rofsky
Hepatic metastases: perilesional enhancement on dynamic MRI.
Am. J. Roentgenol., April 1, 2006; 186(4): 1051 - 1058.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
I. Pedrosa, M. Morrin, L. Oleaga, J. Baptista, and N. M. Rofsky
Is True FISP Imaging Reliable in the Evaluation of Venous Thrombosis?
Am. J. Roentgenol., December 1, 2005; 185(6): 1632 - 1640.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. B. Pitton, H. Schweitzer, S. Herber, W. Schmiedt, A. Neufang, P. Kalden, M. Thelen, and C. Duber
MRI Versus Helical CT for Endoleak Detection After Endovascular Aneurysm Repair
Am. J. Roentgenol., November 1, 2005; 185(5): 1275 - 1281.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. M. Israel and M. A. Bosniak
How I Do It: Evaluating Renal Masses
Radiology, August 1, 2005; 236(2): 441 - 450.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. L. Zhang, B. Y. Ho, M. Chao, K. C. Kent, H. L. Bush, P. L. Faries, A. I. Benvenisty, and M. R. Prince
Decreased Venous Contamination on 3D Gadolinium-Enhanced Bolus Chase Peripheral MR Angiography Using Thigh Compression
Am. J. Roentgenol., October 1, 2004; 183(4): 1041 - 1047.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
P Manoharan and J Ward
MRI in the assessment of focal liver lesions in the non-cirrhotic patient
Imaging, September 1, 2004; 16(4): 338 - 350.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. M. Hecht, G. M. Israel, G. A. Krinsky, W. Y. Hahn, D. C. Kim, I. Belitskaya-Levy, and V. S. Lee
Renal Masses: Quantitative Analysis of Enhancement with Signal Intensity Measurements versus Qualitative Analysis of Enhancement with Image Subtraction for Diagnosing Malignancy at MR Imaging
Radiology, August 1, 2004; 232(2): 373 - 378.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K.-F. J. Kreitner, S. Ley, H.-U. Kauczor, E. Mayer, T. Kramm, M. B. Pitton, F. Krummenauer, and M. Thelen
Chronic Thromboembolic Pulmonary Hypertension: Pre- and Postoperative Assessment with Breath-hold MR Imaging Techniques
Radiology, August 1, 2004; 232(2): 535 - 543.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. W. Olin, J. A. Kaufman, D. A. Bluemke, R. O. Bonow, M. D. Gerhard, M. R. Jaff, G. D. Rubin, and W. Hall
Atherosclerotic Vascular Disease Conference: Writing Group IV: Imaging
Circulation, June 1, 2004; 109(21): 2626 - 2633.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. P. Kunz, K. Oberholzer, W. Kuroczynski, G. Horstick, F. Krummenauer, M. Thelen, and K.-F. Kreitner
Assessment of Chronic Aortic Dissection: Contribution of Different ECG-Gated Breath-Hold MRI Techniques
Am. J. Roentgenol., May 1, 2004; 182(5): 1319 - 1326.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. T. Bae
Peak Contrast Enhancement in CT and MR Angiography: When Does It Occur and Why? Pharmacokinetic Study in a Porcine Model
Radiology, June 1, 2003; 227(3): 809 - 816.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J.-S. Yu and N. M. Rofsky
Dynamic Subtraction MR Imaging of the Liver: Advantages and Pitfalls
Am. J. Roentgenol., May 1, 2003; 180(5): 1351 - 1357.
[Full Text] [PDF]


Home page
RadiologyHome page
C. J. Francois, S. M. Shors, R. O. Bonow, and J. P. Finn
Analysis of Cardiopulmonary Transit Times at Contrast Material-enhanced MR Imaging in Patients with Heart Disease
Radiology, May 1, 2003; 227(2): 447 - 452.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. S. Lee, H. Rusinek, M. E. Noz, P. Lee, M. Raghavan, and E. L. Kramer
Dynamic Three-dimensional MR Renography for the Measurement of Single Kidney Function: Initial Experience
Radiology, April 1, 2003; 227(1): 289 - 294.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
N. Wolosker, L. Nakano, G. D'Hippolito, R. A. Rosoky, M. L. Borri, and A. M. B. Wolosker
Gadolinium Magnetic Angioresonance in the Study of Aortoiliac Disease
Angiology, March 1, 2003; 54(2): 163 - 168.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
P. V. Pandharipande, V. S. Lee, P. M. Reuss, H. W. Charles, R. J. Rosen, G. A. Krinsky, J. C. Weinreb, and N. M. Rofsky
Two-Station Bolus-Chase MR Angiography with a Stationary Table: A Simple Alternative to Automated-Table Techniques
Am. J. Roentgenol., December 1, 2002; 179(6): 1583 - 1589.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. M. Israel, V. S. Lee, M. Edye, G. A. Krinsky, M. T. Lavelle, T. Diflo, and J. C. Weinreb
Comprehensive MR Imaging in the Preoperative Evaluation of Living Donor Candidates for Laparoscopic Nephrectomy: Initial Experience
Radiology, November 1, 2002; 225(2): 427 - 432.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. S. Swan, T. J. Carroll, T. W. Kennell, D. M. Heisey, F. R. Korosec, R. Frayne, C. A. Mistretta, and T. M. Grist
Time-resolved Three-dimensional Contrast-enhanced MR Angiography of the Peripheral Vessels
Radiology, October 1, 2002; 225(1): 43 - 52.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
N. Kawaharada, K. Morishita, J. Fukada, A. Yamada, S. Muraki, H. Hyodoh, and T. Abe
Thoracoabdominal or descending aortic aneurysm repair after preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography
Eur. J. Cardiothorac. Surg., June 1, 2002; 21(6): 970 - 974.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. J. Kroencke, M. Taupitz, R. Arnold, L. Fritsche, and B. Hamm
Three-Dimensional Gadolinium-Enhanced Magnetic Resonance Venography in Suspected Thrombo-occlusive Disease of the Central Chest Veins
Chest, November 1, 2001; 120(5): 1570 - 1576.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. W. Goldfarb, M. G. Hochman, D. S. Kim, and R. R. Edelman
Contrast-Enhanced MR Angiography and Perfusion Imaging of the Hand
Am. J. Roentgenol., November 1, 2001; 177(5): 1177 - 1182.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. J. Carroll, F. R. Korosec, G. M. Petermann, T. M. Grist, and P. A. Turski
Carotid Bifurcation: Evaluation of Time-resolved Three-dimensional Contrast-enhanced MR Angiography
Radiology, August 1, 2001; 220(2): 525 - 532.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Masunaga, Y. Takehara, H. Isoda, T. Igarashi, M. Sugiyama, S. Isogai, N. Kodaira, H. Takeda, A. Nozaki, and H. Sakahara
Assessment of Gadolinium-Enhanced Time-Resolved Three-Dimensional MR Angiography for Evaluating Renal Artery Stenosis
Am. J. Roentgenol., May 1, 2001; 176(5): 1213 - 1219.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. B. Fain, B. F. King, J. F. Breen, D. G. Kruger, and S. J. Riederer
High-Spatial-Resolution Contrast-enhanced MR Angiography of the Renal Arteries: A Prospective Comparison with Digital Subtraction Angiography
Radiology, February 1, 2001; 218(2): 481 - 490.
[Abstract] [Full Text]


Home page
RadiologyHome page
K. Mitsuzaki, Y. Yamashita, T. Sakaguchi, I. Ogata, M. Takahashi, and Y. Hiai
Abdomen, Pelvis, and Extremities: Diagnostic Accuracy of Dynamic Contrast-enhanced Turbo MR Angiography Compared with Conventional Angiography-Initial Experience
Radiology, September 1, 2000; 216(3): 909 - 915.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
W. B. Eubank, U. P. Schmiedl, A. E. Levy, and C. L. Marsh
Venous Thrombosis and Occlusion After Pancreas Transplantation: Evaluation with Breath-Hold Gadolinium-Enhanced Three-Dimensional MR Imaging
Am. J. Roentgenol., August 1, 2000; 175(2): 381 - 385.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Chiowanich, D. G. Mitchell, H. V. Ortega, and F. Mohamed
Arterial Pseudostenosis on First-Pass Gadolinium-Enhanced Three-Dimensional MR Angiography: New Observation of a Potential Pitfall
Am. J. Roentgenol., August 1, 2000; 175(2): 523 - 527.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
N. Yamada, Y. Okita, K. Minatoya, O. Tagusari, M. Ando, M. Takamiya, and S. Kitamura
Preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography in patients with descending or thoracoabdominal aortic aneurysms
Eur. J. Cardiothorac. Surg., July 1, 2000; 18(1): 104 - 111.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Kreft, H. Strunk, S. Flacke, M. Wolff, R. Conrad, J. Gieseke, D. Pauleit, R. Bachmann, A. Hirner, and H. H. Schild
Detection of Thrombosis in the Portal Venous System: Comparison of Contrast-enhanced MR Angiography with Intraarterial Digital Subtraction Angiography
Radiology, July 1, 2000; 216(1): 86 - 92.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
D. Weishaupt, S. G. Ruhm, C. A. Binkert, M. Schmidt, M. A. Patak, F. Steybe, S. McGill, and J. F. Debatin
Equilibrium-Phase MR Angiography of the Aortoiliac and Renal Arteries Using a Blood Pool Contrast Agent
Am. J. Roentgenol., July 1, 2000; 175(1): 189 - 195.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. S. Lee, D. J. Martin, G. A. Krinsky, and N. M. Rofsky
Gadolinium-Enhanced MR Angiography: Artifacts and Pitfalls
Am. J. Roentgenol., July 1, 2000; 175(1): 197 - 205.
[Full Text] [PDF]


Home page
RadiologyHome page
V. S. Lee, M. T. Lavelle, N. M. Rofsky, G. Laub, D. M. Thomasson, G. A. Krinsky, and J. C. Weinreb
Hepatic MR Imaging with a Dynamic Contrast-enhanced Isotropic Volumetric Interpolated Breath-hold Examination: Feasibility, Reproducibility, and Technical Quality
Radiology, May 1, 2000; 215(2): 365 - 372.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. J. Riederer, M. A. Bernstein, J. F. Breen, R. F. Busse, R. L. Ehman, S. B. Fain, T. C. Hulshizer, J. H. III, B. F. King, D. G. Kruger, et al.
Three-dimensional Contrast-enhanced MR Angiography with Real-time Fluoroscopic Triggering: Design Specifications and Technical Reliability in 330 Patient Studies
Radiology, May 1, 2000; 215(2): 584 - 593.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. B. J. M. Korst, F. B. M. Joosten, C. T. Postma, G. J. Jager, J. K. Krabbe, and J. O. Barentsz
Accuracy of Normal-Dose Contrast-Enhanced MR Angiography in Assessing Renal Artery Stenosis and Accessory Renal Artery Stenosis and Accessory Renal Arteries
Am. J. Roentgenol., March 1, 2000; 174(3): 629 - 634.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
O. Ernst, V. Asnar, G. Sergent, E. Lederman, L. Nicol, J.-C. Paris, and C. L'Hermine
Comparing Contrast-Enhanced Breath-Hold MR Angiography and Conventional Angiography
Am. J. Roentgenol., February 1, 2000; 174(2): 433 - 439.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. S. Lee, N. M. Rofsky, A. T. Ton, G. Johnson, G. A. Krinsky, and J. C. Weinreb
Angiotensin-Converting Enzyme Inhibitor-Enhanced Phase-Contrast MR Imaging to Measure Renal Artery Velocity Waveforms in Patients with Suspected Renovascular Hypertension
Am. J. Roentgenol., February 1, 2000; 174(2): 499 - 508.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. M. Rofsky and M. A. Adelman
MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease
Radiology, February 1, 2000; 214(2): 325 - 338.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
K.-F. Kreitner, P. Kalden, A. Neufang, C. Duber, F. Krummenauer, E. Kustner, G. Laub, and M. Thelen
Diabetes and Peripheral Arterial Occlusive Disease: Prospective Comparison of Contrast-Enhanced Three-Dimensional MR Angiography with Conventional Digital Subtraction
Am. J. Roentgenol., January 1, 2000; 174(1): 171 - 179.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
Y. Watanabe, M. Dohke, A. Okumura, Y. Amoh, T. Ishimori, K. Oda, T. Hayashi, A. Hiyama, and Y. Dodo
Dynamic Subtraction Contrast-enhanced MR Angiography: Technique, Clinical Applications, and Pitfalls
RadioGraphics, January 1, 2000; 20(1): 135 - 152.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Mitsuzaki, Y. Yamashita, I. Ogata, Y. Tang, T. Namimoto, and M. Takahashi
Optimal Protocol for Injection of Contrast Material at MR Angiography: Study of Healthy Volunteers
Radiology, December 1, 1999; 213(3): 913 - 918.
[Abstract] [Full Text]


Home page
CirculationHome page
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce
Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries
Circulation, November 30, 1999; 100(22): 2284 - 2301.
[Full Text] [PDF]


Home page
RadiologyHome page
T. S. Shinde, V. S. Lee, N. M. Rofsky, G. A. Krinsky, and J. C. Weinreb
Three-dimensional Gadolinium-enhanced MR Venographic Evaluation of Patency of Central Veins in the Thorax: Initial Experience
Radiology, November 1, 1999; 213(2): 555 - 560.
[Abstract] [Full Text]


Home page
RadiologyHome page
N. M. Rofsky, V. S. Lee, G. Laub, M. A. Pollack, G. A. Krinsky, D. Thomasson, M. M. Ambrosino, and J. C. Weinreb
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Radiology, September 1, 1999; 212(3): 876 - 884.
[Abstract] [Full Text]


Home page
RadiologyHome page
J. Link, J. C. Steffens, J. Brossmann, J. Graessner, S. Hackethal, and M. Heller
Iliofemoral Arterial Occlusive Disease: Contrast-enhanced MR Angiography for Preinterventional Evaluation and Follow-up after Stent Placement
Radiology, August 1, 1999; 212(2): 371 - 377.
[Abstract] [Full Text]


Home page
RadiologyHome page
L. Kopka, J. Rodenwaldt, R. Vosshenrich, U. Fischer, B. Renner, T. Lorf, J. Graessner, B. Ringe, and E. Grabbe
Hepatic Blood Supply: Comparison of Optimized Dual Phase Contrast-enhanced Three-dimensional MR Angiography and Digital Subtraction Angiography
Radiology, April 1, 1999; 211(1): 51 - 58.
[Abstract] [Full Text]


Home page
RadiologyHome page
V. S. Lee, N. M. Rofsky, G. A. Krinsky, D. H. Stemerman, and J. C. Weinreb
Single-Dose Breath-hold Gadolinium-enhanced Three-dimensional MR Angiography of the Renal Arteries
Radiology, April 1, 1999; 211(1): 69 - 78.
[Abstract] [Full Text]


Home page
RadiologyHome page
E. K. Yucel
Pulmonary MR Angiography: Is It Ready Now?
Radiology, February 1, 1999; 210(2): 301 - 303.
[Full Text]


Home page
RadiologyHome page
V. S. Lee, H. Rusinek, G. Johnson, N. M. Rofsky, G. A. Krinsky, and J. C. Weinreb
MR Renography with Low-Dose Gadopentetate Dimeglumine: Feasibility
Radiology, November 1, 2001; 221(2): 371 - 379.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.