Radiology, Vol 202, 117-124, Copyright © 1997 by Radiological Society of North America
ARTICLES |
E Samei, MJ Flynn and WR Eyler
Department of Diagnostic Radiology, Henry Ford Health System, Detroit, MI 48202, USA.
PURPOSE: To measure the radiologic characteristics of subtle lung nodules and develop nodule phantoms that simulate these characteristics. MATERIALS AND METHODS: From a database of chest radiographs, 16 radiographs that showed confirmed subtle lung nodules were selected. The optical density values surrounding each nodule were obtained, and the radiologic characteristic of the nodules were evaluated. A set of Teflon nodule phantoms with similar x-ray transmission and variability was designed and fabricated. The contrast characteristics of the images of the nodule phantoms were measured. RESULTS: Most of the subtle nodules appeared to have diffuse edges with Gaussian-like contrast profiles. The contrast and size characteristics of the nodule phantom images fulfilled the design criteria within a 4% deviation. CONCLUSION: The radiologic pattern of subtle lung nodules is poorly simulated by nodule phantoms with simple spherical or disk shapes. The nodule phantoms in this study produce realistic radiographic patterns with an energy-dependent attenuation equivalent to that of tissue. The nodule phantoms are intended for use in experiments involving human subjects.
This article has been cited by other articles:
![]() |
E. Samei, S. A. Stebbins, J. T. Dobbins III, and J. Y. Lo Multiprojection Correlation Imaging for Improved Detection of Pulmonary Nodules Am. J. Roentgenol., May 1, 2007; 188(5): 1239 - 1245. [Abstract] [Full Text] [PDF] |
||||
![]() |
D S Brettle, E Berry, and M A Smith The effect of experience on detectability in local area anatomical noise Br. J. Radiol., March 1, 2007; 80(951): 186 - 193. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. Hoe, E. Samei, D. P. Frush, and D. M. Delong Simulation of Liver Lesions for Pediatric CT Radiology, December 21, 2005; (2005) 2381050477. [Abstract] [Full Text] |
||||
![]() |
K Ono, T Yoshitake, K Akahane, Y Yamada, T Maeda, M Kai, and T Kusama Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinoma lesions using hard copy images Br. J. Radiol., October 1, 2005; 78(934): 922 - 927. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. R. Turner, E. Samei, B. S. Hertzberg, D. M. DeLong, R. Vargas-Voracek, A. Singer, C. H. Maynor, and M. A. Kliewer Sonography of Fetal Choroid Plexus Cysts: Detection Depends on Cyst Size and Gestational Age J. Ultrasound Med., November 1, 2003; 22(11): 1219 - 1227. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Samei, M. J. Flynn, E. Peterson, and W. R. Eyler Subtle Lung Nodules: Influence of Local Anatomic Variations on Detection Radiology, July 1, 2003; 228(1): 76 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Samei, M. J. Flynn, and W. R. Eyler Detection of Subtle Lung Nodules: Relative Influence of Quantum and Anatomic Noise on Chest Radiographs Radiology, December 1, 1999; 213(3): 727 - 734. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |