Radiology, Vol 202, 125-130, Copyright © 1997 by Radiological Society of North America
ARTICLES |
HP Weskott
Department of Internal Medicine II, Stadtisches Krankenhaus Siloah, Hannover, Germany.
PURPOSE: To evaluate the in vitro sensitivity for the detection of slow blood flow in tiny tubes with an amplitude Doppler ultrasound (US) technique at different angles and pulse repetition frequencies. MATERIALS AND METHODS: Human blood treated with heparin was pumped through silicone tubes (flow phantoms made by the author) with lumina of 3.00 mm, 0.30 mm, and 0.05 mm. Slow flow was imaged by using amplitude and color Doppler US techniques with two US devices at different pulse repetition frequencies and angles and in different sound propagation media. RESULTS: Under ideal conditions, the lowest detectable velocity was 0.04-0.06 cm/sec in the 3.00-mm tube. Detection was about three to four times less sensitive in the 0.30-mm and 0.05-mm tubes. Amplitude Doppler US sensitivity is only slightly dependent on the angle of incidence and propagation medium. CONCLUSION: The fractional volume flow determined the sensitivity of the amplitude Doppler technique for detecting low flow. Amplitude Doppler US is nearly angle independent; thus, it is superior to color Doppler US. Amplitude Doppler US is three to four times more sensitive when tube have very tiny lumina and when probes of a lower frequency are used.
This article has been cited by other articles:
![]() |
P. Malliaras, P. J. Richards, G. Garau, and N. Maffulli Achilles Tendon Doppler Flow May Be Associated With Mechanical Loading Among Active Athletes Am. J. Sports Med., November 1, 2008; 36(11): 2210 - 2215. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Kim, J. M. Lee, Y. J. Kim, J. Y. Lee, J. K. Han, and B. I. Choi High-Definition Flow Doppler Ultrasonographic Technique to Assess Hepatic Vasculature Compared With Color or Power Doppler Ultrasonography: Preliminary Experience J. Ultrasound Med., October 1, 2008; 27(10): 1491 - 1501. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Knobloch, R.-J. de Vos, A. Weir, and J. L. Tol Letters to the Editor * Authors' Response Am. J. Sports Med., February 1, 2008; 36(2): 395 - 397. [Full Text] [PDF] |
||||
![]() |
K. Knobloch, R. Kraemer, A. Lichtenberg, M. Jagodzinski, T. Gossling, M. Richter, J. Zeichen, T. Hufner, and C. Krettek Achilles Tendon and Paratendon Microcirculation in Midportion and Insertional Tendinopathy in Athletes Am. J. Sports Med., January 1, 2006; 34(1): 92 - 97. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Aso, G. Enriquez, M. Fite, N. Toran, C. Piro, J. Piqueras, and J. Lucaya Gray-Scale and Color Doppler Sonography of Scrotal Disorders in Children: An Update RadioGraphics, September 1, 2005; 25(5): 1197 - 1214. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Walther, H. Harms, V. Krenn, S. Radke, S. Kirschner, and F. Gohlke Synovial Tissue of the Hip at Power Doppler US: Correlation between Vascularity and Power Doppler US Signal Radiology, October 1, 2002; 225(1): 225 - 231. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Claudon, D. Winninger, S. Briançon, and P. Pesque Power Doppler US: Evaluation of the Morphology of Stenoses with a Flow Phantom Radiology, January 1, 2001; 218(1): 109 - 117. [Abstract] [Full Text] |
||||
![]() |
V. Wolfson, I. Tsikonova, D. Keren, E. Barmeir, D. Yeshurun, and J. E. Naschitz Pulsatile Venous Insufficiency in Severe Tricuspid Regurgitation: Does Pulsatility Protect Against Complications of Venous Disease? Angiology, March 1, 2000; 51(3): 231 - 239. [Abstract] [PDF] |
||||
![]() |
T. Y. Cheng, T. Janik, and R. B. Meacham Construction of a Flow Phantom for Use in Color Power Sonography Journal of Diagnostic Medical Sonography, January 1, 1999; 15(1): 23 - 25. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |