Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McAdams, H. P.
Right arrow Articles by Davis, R. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McAdams, H. P.
Right arrow Articles by Davis, R. D.

Radiology, Vol 203, 202-206, Copyright © 1997 by Radiological Society of North America


ARTICLES

Telescoping bronchial anastomoses for unilateral or bilateral sequential lung transplantation: CT appearance

HP McAdams, JG Murray, JJ Erasmus, PC Goodman, VF Tapson and RD Davis
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA.

PURPOSE: To determine the computed tomographic (CT) appearance of telescoping bronchial anastomoses. MATERIALS AND METHODS: CT scans obtained in 36 adult patients with 54 telescoping anastomoses (30 right bronchus, 24 left bronchus) were retrospectively reviewed. Seventeen scans were obtained with 10-mm collimation, one with 5-mm collimation, and 18 with 3-mm collimation. Multiplanar volume reconstruction images were retrospectively generated in 19 patients. CT findings were correlated with fiberoptic bronchoscopic findings and clinical records. RESULTS: Smooth, spherical air collections caused by diverticula of redundant mucosa were seen at the inferior or medial aspect of 22 anastomoses (41%). Endoluminal flaps and linear air collections caused by separation of the invaginated bronchus from the recipient bronchus were seen in 16 anastomoses (30%). Flaps and linear air collections were seen only at the anterior, superior, or inferior aspects of the anastomosis. Flaps and diverticula were more common at right anastomoses than at left anastomoses. No patient with an endoluminal flap or diverticulum at CT had dehiscence at bronchoscopy. Irregular air collections or posterior wall defects were suggestive of dehiscence at four anastomoses (7%). Dehiscence was confirmed bronchoscopically at two of these four anastomoses. CONCLUSION: Endoluminal flaps and linear or spherical air collections can be a normal feature of the telescoping anastomosis and should not necessarily be interpreted as dehiscence.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. R. Gill, A. C. Poh, P. C. Camp, J. M. Allen, M. T. Delano, F. L. Jacobson, A. Hunsaker, and Y. L. Colson
MDCT Evaluation of Central Airway and Vascular Complications of Lung Transplantation
Am. J. Roentgenol., October 1, 2008; 191(4): 1046 - 1056.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G.R. Ferretti, I. Bricault, and M. Coulomb
Virtual tools for imaging of the thorax
Eur. Respir. J., August 1, 2001; 18(2): 381 - 392.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.