Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schurmann, K.
Right arrow Articles by Gunther, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schurmann, K.
Right arrow Articles by Gunther, R. W.

Radiology, Vol 203, 55-63, Copyright © 1997 by Radiological Society of North America


ARTICLES

Iliac arteries: plain and heparin-coated Dacron-covered stent-grafts compared with noncovered metal stents--an experimental study

K Schurmann, D Vorwerk, R Uppenkamp, B Klosterhalfen, A Bucker and RW Gunther
Department of Diagnostic Radiology, University of Technology, Aachen, Germany.

PURPOSE: To compare lumen patency, neointimal thickening, and local inflammatory reaction with noncovered metal stents and plain and heparin-coated Dacron-covered stent-grafts. MATERIALS AND METHODS: In each of 16 sheep, four prostheses were placed in the iliac arteries: a plain and a heparin-coated Dacron-covered Cragg stent-graft, a noncovered Cragg stent, and a noncovered Memotherm nitinol stent. Two prostheses were inserted in the iliac artery on each side. Patency was monitored with angiography and intravascular ultrasound (US). Eight animals were killed at 1-month follow-up, and the other eight at 6 month follow-up. Neointimal thickening and inflammatory foreign-body reaction to the prostheses were determined macroscopically and with light microscopy. RESULTS: More than 50% stenosis developed in 10 heparin-coated and three plain Dacron-covered stent-grafts but not in the noncovered stents. Two heparin-coated and one plain Dacron-covered stent-graft occluded completely. Neointimal thickening and inflammatory reaction were severe with the heparin-coated Dacron-covered stent- grafts, were less with the plain Dacron-covered stent-grafts, and were least with the noncovered stents. CONCLUSION: Neointimal thickening and inflammatory reaction significantly increased with covered compared with noncovered prostheses in the iliac arteries in sheep and were worst with heparin-coated Dacron-covered stent-grafts. If possible, use of noncovered stents should thus be preferred to use of Dacron-covered stent-grafts.


This article has been cited by other articles:


Home page
RadiologyHome page
K. Schurmann, J. Lahann, P. Niggemann, B. Klosterhalfen, J. Meyer, A. Kulisch, D. Klee, R. W. Gunther, and D. Vorwerk
Biologic Response to Polymer-coated Stents: In Vitro Analysis and Results in an Iliac Artery Sheep Model
Radiology, January 1, 2004; 230(1): 151 - 162.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. A. Meyer, B. Nowak, K. Schuermann, A. Buecker, F. Moltzahn, A. Kulisch, N. Heussen, T. Gorgen, U. Bull, and R. W. Gunther
Inhibition of Neointimal Proliferation with 188Re-labeled Self-Expanding Nitinol Stent in a Sheep Model
Radiology, December 1, 2003; 229(3): 847 - 854.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Ahmadi, M. Schillinger, T. Maca, and E. Minar
Femoropopliteal Arteries: Immediate and Long-term Results with a Dacron-covered Stent-Graft
Radiology, March 21, 2002; (2002) 2232010971.
[Abstract] [Full Text]


Home page
RadiologyHome page
Z. J. Haskal and L. H. Brennecke
Transjugular Intrahepatic Portosystemic Shunts Formed with Polyethylene Terephthalate-covered Stents: Experimental Evaluation in Pigs
Radiology, December 1, 1999; 213(3): 853 - 859.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. Ahmadi, M. Schillinger, T. Maca, and E. Minar
Femoropopliteal Arteries: Immediate and Long-term Results with a Dacron-covered Stent-Graft
Radiology, May 1, 2002; 223(2): 345 - 350.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.