Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Correction (v207,p278)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suleiman, O. H.
Right arrow Articles by Spelic, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suleiman, O. H.
Right arrow Articles by Spelic, D. C.

Radiology, Vol 203, 471-476, Copyright © 1997 by Radiological Society of North America


ARTICLES

Nationwide survey of fluoroscopy: radiation dose and image quality [published erratum appears in Radiology 1998 Apr;207(1):278]

OH Suleiman, BJ Conway, P Quinn, RG Antonsen, FG Rueter, RJ Slayton and DC Spelic
Center for Devices and Radiological Health, U.S. Food and Drug Administration, Rockville, Md. 20850, USA.

PURPOSE: To determine the average abdominal entrance air kerma, low- contrast sensitivity, and spatial resolution in upper gastrointestinal tract fluoroscopy in the United States. MATERIALS AND METHODS: A random sample of fluoroscopic facilities was selected to be surveyed for the Nationwide Evaluation of X-ray Trends program. Measurements were performed by using a newly developed fluoroscopic phantom. The surveys were conducted by state radiation control personnel. RESULTS: Average air kerma rates 1 cm above the tabletop, free in air, were 43 mGy/min (n = 340). The rate increased to 64 mGy/min when a 1.6-mm-thick copper filter, which simulated the use of barium contrast medium, was added to increase attenuation. The average entrance air kerma, free in air, for radiographs was 3.4 mGy, and an average of 12 radiographs were obtained per examination. Of 352 facilities surveyed, 306 (87%) were able to resolve wire mesh with 20 or more lines per inch. Of 339 facilities for which percentage contrast could be calculated, 192 (57%) had minimum percentage contrast values of 4% or more. CONCLUSION: Spatial resolution for fluoroscopy is adequate for most of the facilities surveyed, but a substantial proportion of facilities could not visualize low-contrast test objects, which strongly suggests image quality problems.


This article has been cited by other articles:


Home page
RadiologyHome page
D. C. Spelic, R. V. Kaczmarek, and O. H. Suleiman
Nationwide Evaluation of X-ray Trends Survey of Abdomen and Lumbosacral Spine Radiography
Radiology, July 1, 2004; 232(1): 115 - 125.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. P. Taubel, B. A. Schueler, T. J. Vrieze, and J. E. Gray
Quantification of Fluoroscopic Imaging System Contrast by Using Video Waveform Monitoring
RadioGraphics, March 1, 2001; 21(2): 507 - 518.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. B. Peter, W. Pavlicek, and J. M. Owen
Soft-Copy Quality Control of Digital Spot Images Obtained by Using X-ray Image Intensifiers
Radiology, September 1, 2000; 216(3): 810 - 819.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.