|
|
||||||||
Radiology, Vol 204, 101-104, Copyright © 1997 by Radiological Society of North America
ARTICLES |
DM Plecha, DW Goodwin, DY Rowland, ME Varnes and JR Haaga
Department of Radiology, University Hospitals of Cleveland, OH 44106, USA.
PURPOSE: To evaluate different-caliber biopsy cutting needles in terms of the benefits and potential risk of bleeding in a swine model. MATERIALS AND METHODS: A total of 190 sequential liver biopsy specimens were obtained in 11 Yorkshire pigs (weight, 50-70 lb [22.5-31.5 kg]) by using 14-, 18-, and 20-gauge cutting needles. For each biopsy procedure, blood loss was determined by weighing sponges used to absorb bleeding, and sample-tissue DNA content was measured with spectrofluorometry. Analysis of variance was used to compare results. RESULTS: The larger the caliber of needle, the greater the absolute blood loss (for 14-gauge, 1.69 g; for 18-gauge, 0.74 g; for 20-gauge, 0.32 g) and DNA content per sample (for 14 gauge, 40.38 microg; for 18- gauge, 12.18 microg; for 20-gauge, 5.86 microg). The ratio of blood loss to amount of DNA recovered did not differ among the different- caliber needles. To obtain the same amount of diagnostic tissue, more passes were needed with the smaller-caliber needles. CONCLUSION: Use of larger-caliber needles is more efficient despite the greater amount of blood loss, because more tissue can be recovered and because fewer passes are necessary, which reduces the chances of complications.
This article has been cited by other articles:
![]() |
L. F. Pupulim, M. Felce-Dachez, V. Paradis, M.-P. Vullierme, M. Zappa, P. Bedossa, and V. Vilgrain Algorithm for Immediate Cytologic Diagnosis of Hepatic Tumors Am. J. Roentgenol., March 1, 2008; 190(3): W208 - W212. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Heo, H. G. Kattesh, M. P. Roberts, J. L. Morrow, J. W. Dailey, and A. M. Saxton Hepatic corticosteroid-binding globulin (CBG) messenger RNA expression and plasma CBG concentrations in young pigs in response to heat and social stress J Anim Sci, January 1, 2005; 83(1): 208 - 215. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. F. Lang, M. R. Gilbert, V. K. Puduvalli, J. Weinberg, V. A. Levin, W.K. A. Yung, R. Sawaya, G. N. Fuller, and C. A. Conrad Toward better early-phase brain tumor clinical trials: A reappraisal of current methods and proposals for future strategies Neuro-oncol, October 1, 2002; 4(4): 268 - 277. [Abstract] [PDF] |
||||
![]() |
A. Dowlati, J. Haaga, S. C. Remick, T. P. Spiro, S. L. Gerson, L. Liu, S. J. Berger, N. A. Berger, and J. K. V. Willson Sequential Tumor Biopsies in Early Phase Clinical Trials of Anticancer Agents for Pharmacodynamic Evaluation Clin. Cancer Res., October 1, 2001; 7(10): 2971 - 2976. [Abstract] [Full Text] [PDF] |
||||
![]() |
S N SCHOTMAN, R A DE MAN, J STOKER, P E ZONDERVAN, and J N M IJZERMANS Subcutaneous seeding of hepatocellular carcinoma after percutaneous needle biopsy Gut, October 1, 1999; 45(4): 626 - 627. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |