Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olcott, E. W.
Right arrow Articles by Napel, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olcott, E. W.
Right arrow Articles by Napel, S.

Radiology, Vol 204, 19-25, Copyright © 1997 by Radiological Society of North America


ARTICLES

Accuracy of detection and measurement of renal calculi: in vitro comparison of three-dimensional spiral CT, radiography, and nephrotomography

EW Olcott, FG Sommer and S Napel
Veterans Affairs Palo Alto Health Care System, and the Department of Radiology, Stanford University School of Medicine, Calif 94304, USA.

PURPOSE: To compare accuracy of three-dimensional (3D) spiral computed tomography (CT) performed without administration of contrast material with that of radiography and linear nephrotomography in detection and measurement of renal calculi. MATERIALS AND METHODS: Fifty renal calculi within an abdominal phantom were imaged with 3D spiral CT, radiography, and linear nephrotomography. Spiral CT data were analyzed with workstation-based 3D imaging software, with a thresholding procedure based on the maximally attenuating voxel within each calculus during measurement. Measurement accuracy and detection rates were compared according to modality. Conventional and magnification- corrected measurements from radiography and linear nephrotomography were included. RESULTS: Spiral CT depicted calculi and allowed determination of the collective two-dimensional and 3D linear measurements statistically significantly more accurately than the other techniques; the mean linear measurement errors along individual axes did not exceed 3.6%. With 3D spiral CT, calculus volumes were determined with a mean error of -4.8%. CONCLUSION: 3D spiral CT enabled highly accurate determination of the volumes and all three linear dimensions of renal calculi. In addition, 3D spiral CT depicted calculi more sensitively than traditional techniques and provided new information and improved accuracy in the evaluation of nephrolithiasis.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. Grosjean, B. Sauer, R. M. Guerra, M. Daudon, A. Blum, J. Felblinger, and J. Hubert
Characterization of Human Renal Stones with MDCT: Advantage of Dual Energy and Limitations Due to Respiratory Motion
Am. J. Roentgenol., March 1, 2008; 190(3): 720 - 728.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. E. Van Beers, S. Dechambre, P. Hulcelle, R. Materne, and J. Jamart
Value of Multislice Helical CT Scans and Maximum-Intensity-Projection Images to Improve Detection of Ureteral Stones at Abdominal Radiography
Am. J. Roentgenol., November 1, 2001; 177(5): 1117 - 1121.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. C. Saw, J. A. McAteer, A. G. Monga, G. T. Chua, J. E. Lingeman, and J. C. Williams Jr.
Helical CT of Urinary Calculi: Effect of Stone Composition, Stone Size, and Scan Collimation
Am. J. Roentgenol., August 1, 2000; 175(2): 329 - 332.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. A. Urban and E. K. Fishman
Tailored Helical CT Evaluation of Acute Abdomen : (CME available in print version and on RSNA Link)
RadioGraphics, May 1, 2000; 20(3): 725 - 749.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Sudah, R. L. Vanninen, K. Partanen, S. Kainulainen, A. Malinen, A. Heino, and M. Ala-Opas
Patients with Acute Flank Pain: Comparison of MR Urography with Unenhanced Helical CT
Radiology, April 1, 2002; 223(1): 98 - 105.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.