Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kuhl, C. K.
Right arrow Articles by Schild, H. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuhl, C. K.
Right arrow Articles by Schild, H. H.

Radiology, Vol 204, 667-675, Copyright © 1997 by Radiological Society of North America


ARTICLES

Interventional breast MR imaging: clinical use of a stereotactic localization and biopsy device

CK Kuhl, A Elevelt, CC Leutner, J Gieseke, E Pakos and HH Schild
Department of Radiology, University of Bonn, Germany.

PURPOSE: To evaluate the usefulness of preoperative magnetic resonance (MR) imaging-guided stereotactic localization and core biopsy of suspicious breast lesions that are visible at breast MR imaging alone (ie, that are clinically, mammographically, and ultrasonographically occult), with the goal of integrating this technique into the diagnostic and therapeutic work-up of MR-suspicious lesions in a clinical setting. MATERIALS AND METHODS: A stereotactic breast biopsy device was used for needle placement in and guide wire localization of 97 lesions in 66 patients or core biopsy of five lesions in five patients; all lesions were visible at MR imaging. Interventions were performed with MR guidance on a 0.5- or 1.5-T system. RESULTS: Lesion localization and resection were successful in 95 of the 97 lesions; two of the lesions were not resected in spite of correct guide wire localization. In this series, 53 (55%) of 97 lesions proved malignant (11 [21%] in situ; 42 [79%] invasive). Lesions were 4-19 mm (mean, 8.7 mm); all invasive cancers corresponded to a pT1 tumor stage. Location of the lesion in the parenchyma (retroareolar or prepectoral) did not interfere with accessibility. CONCLUSION: MR imaging-guided stereotactic hook-wire placement and excisional biopsy are accurate and effective in managing lesions identified at only breast MR imaging. MR imaging-guided core biopsy holds promise for allowing a definite work- up of these lesions.


This article has been cited by other articles:


Home page
RadiologyHome page
A. Gossmann, C. Bangard, M. Warm, R. K. Schmutzler, P. Mallmann, and K.-J. Lackner
Real-time MR-guided Wire Localization of Breast Lesions by Using an Open 1.0-T Imager: Initial Experience
Radiology, May 1, 2008; 247(2): 535 - 542.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
S. H. Javid, J. W. Carlson, J. E. Garber, R. L. Birdwell, S. Lester, S. Lipsitz, and M. Golshan
Breast MRI Wire-Guided Excisional Biopsy: Specimen Size as Compared to Mammogram Wire-Guided Excisional Biopsy and Implications for Use.
Ann. Surg. Oncol., December 1, 2007; 14(12): 3352 - 3358.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Kuhl
The Current Status of Breast MR Imaging * Part I. Choice of Technique, Image Interpretation, Diagnostic Accuracy, and Transfer to Clinical Practice
Radiology, August 1, 2007; 244(2): 356 - 378.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
K. J. Macura, R. Ouwerkerk, M. A. Jacobs, and D. A. Bluemke
Patterns of Enhancement on Breast MR Images: Interpretation and Imaging Pitfalls
RadioGraphics, November 1, 2006; 26(6): 1719 - 1734.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Erguvan-Dogan, G. J. Whitman, V. A. Nguyen, M. J. Dryden, R. J. Stafford, J. Hazle, K. R. McAlee, M. J. Phelps, M. F. Ice, H. M. Kuerer, et al.
Specimen radiography in confirmation of MRI-guided needle localization and surgical excision of breast lesions.
Am. J. Roentgenol., August 1, 2006; 187(2): 339 - 344.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. A. Causer, C. A. Piron, R. A. Jong, B. N. Curpen, C. A. Luginbuhl, J. E. Glazier, E. Warner, K. Hill, J. Muldoon, G. Taylor, et al.
MR Imaging-guided Breast Localization System with Medial or Lateral Access
Radiology, August 1, 2006; 240(2): 369 - 379.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. V. Ghate, E. L. Rosen, M. S. C. Soo, and J. A. Baker
MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system.
Am. J. Roentgenol., June 1, 2006; 186(6): 1733 - 1736.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, G. Mason, E. A. Morris, and D. D. Dershaw
Does Size Matter? Positive Predictive Value of MRI-Detected Breast Lesions as a Function of Lesion Size
Am. J. Roentgenol., February 1, 2006; 186(2): 426 - 430.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Orel, M. Rosen, C. Mies, and M. D. Schnall
MR Imaging-guided 9-gauge Vacuum-assisted Core-Needle Breast Biopsy: Initial Experience
Radiology, December 1, 2005; 238(1): 54 - 61.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
C. K. Kuhl, S. Schrading, C. C. Leutner, N. Morakkabati-Spitz, E. Wardelmann, R. Fimmers, W. Kuhn, and H. H. Schild
Mammography, Breast Ultrasound, and Magnetic Resonance Imaging for Surveillance of Women at High Familial Risk for Breast Cancer
J. Clin. Oncol., November 20, 2005; 23(33): 8469 - 8476.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. D. Lehman, E. R. DePeri, S. Peacock, M. D. McDonough, W. B. DeMartini, and J. Shook
Clinical Experience with MRI-Guided Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., June 1, 2005; 184(6): 1782 - 1787.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. L. Pereira, J. Fritz, C. W. Koenig, F. Maurer, P. Boehm, A. Badke, M. Mueller-Schimpfle, M. Bitzer, and C. D. Claussen
Preoperative Marking of Musculoskeletal Tumors Guided by Magnetic Resonance Imaging
J. Bone Joint Surg. Am., August 1, 2004; 86(8): 1761 - 1767.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
X. Chen, C. D. Lehman, and K. E. Dee
MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy Needle
Am. J. Roentgenol., April 1, 2004; 182(4): 1075 - 1080.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Morakkabati, C. C. Leutner, A. Schmiedel, H. H. Schild, and C. K. Kuhl
Breast MR Imaging during or Soon after Radiation Therapy
Radiology, December 1, 2003; 229(3): 893 - 901.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, E. A. Morris, D. D. Dershaw, C. M. Thornton, K. J. Van Zee, and L. K. Tan
Fast MRI-Guided Vacuum-Assisted Breast Biopsy: Initial Experience
Am. J. Roentgenol., November 1, 2003; 181(5): 1283 - 1293.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Teifke, H. A. Lehr, T. W. Vomweg, A. Hlawatsch, and M. Thelen
Outcome Analysis and Rational Management of Enhancing Lesions Incidentally Detected on Contrast-Enhanced MRI of the Breast
Am. J. Roentgenol., September 1, 2003; 181(3): 655 - 662.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. D. Lehman, P. R. Eby, X. Chen, K. E. Dee, B. Thursten, and J. McCloskey
MR Imaging--Guided Breast Biopsy Using a Coaxial Technique with a 14-Gauge Stainless Steel Core Biopsy Needle and a Titanium Sheath
Am. J. Roentgenol., July 1, 2003; 181(1): 183 - 185.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Hlawatsch, A. Teifke, M. Schmidt, and M. Thelen
Preoperative Assessment of Breast Cancer: Sonography Versus MR Imaging
Am. J. Roentgenol., December 1, 2002; 179(6): 1493 - 1501.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
I. Bedrosian, J. Schlencker, F. R. Spitz, S. G. Orel, D. L. Fraker, L. S. Callans, M. Schnall, C. Reynolds, and B. J. Czerniecki
Magnetic Resonance Imaging-Guided Biopsy of Mammographically and Clinically Occult Breast Lesions
Ann. Surg. Oncol., June 1, 2002; 9(5): 457 - 461.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. C. Siegmann, M. Muller-Schimpfle, F. Schick, C. T. Remy, N. Fersis, P. Ruck, C. Gorriz, and C. D. Claussen
MR Imaging--Detected Breast Lesions: Histopathologic Correlation of Lesion Characteristics and Signal Intensity Data
Am. J. Roentgenol., June 1, 2002; 178(6): 1403 - 1409.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. A. Morris, L. Liberman, D. D. Dershaw, J. B. Kaplan, L. R. LaTrenta, A. F. Abramson, and D. J. Ballon
Preoperative MR Imaging--Guided Needle Localization of Breast Lesions
Am. J. Roentgenol., May 1, 2002; 178(5): 1211 - 1220.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Orel and M. D. Schnall
MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Radiology, July 1, 2001; 220(1): 13 - 30.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild
MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone
Radiology, July 1, 2001; 220(1): 31 - 39.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
R Warren and P Kessar
A method of coil localization for breast lesions seen only on MRI
Br. J. Radiol., June 1, 2001; 74(882): 548 - 551.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. J. Brenner
Percutaneous Removal of Postbiopsy Marking Clip in the Breast Using Stereotactic Technique
Am. J. Roentgenol., February 1, 2001; 176(2): 417 - 419.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman
Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium
Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199.
[Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, R. K. Schmutzler, C. C. Leutner, A. Kempe, E. Wardelmann, A. Hocke, M. Maringa, U. Pfeifer, D. Krebs, and H. H. Schild
Breast MR Imaging Screening in 192 Women Proved or Suspected to Be Carriers of a Breast Cancer Susceptibility Gene: Preliminary Results
Radiology, April 1, 2000; 215(1): 267 - 279.
[Abstract] [Full Text]


Home page
RadiologyHome page
U. Fischer, L. Kopka, and E. Grabbe
Breast Carcinoma: Effect of Preoperative Contrast-enhanced MR Imaging on the Therapeutic Approach
Radiology, December 1, 1999; 213(3): 881 - 888.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.