|
|
||||||||
Radiology, Vol 205, 153-157, Copyright © 1997 by Radiological Society of North America
ARTICLES |
P Loubeyre, E Angelie, F Grozel, H Abidi and VA Minh
Department of Radiology, Lyon-Sud Hospital, Pierre Benite, France.
PURPOSE: To evaluate a computed tomographic (CT) artifact that simulates aortic dissection. MATERIALS AND METHODS: Two groups of 65 patients underwent spiral CT of the chest for reasons other than suspected aortic dissection. In each group, two series of images (10-mm sections) were reconstructed with use of a 180 degrees or 360 degrees linear-interpolation algorithm. Series of images were read by two radiologists, and variance between interpretations was statistically measured. RESULTS: Among series of images, artifacts were seen on 21-26 (32%-40%) with use of a 180 degrees algorithm and 41 (63%) and 44 (68%) with use of a 360 degrees algorithm. Concordance between reviewers was fair (kappa = 0.58, 0.59) or good (kappa = 0.65) with use of a 180 degrees algorithm and excellent (kappa = 0.92) with use of a 360 degrees algorithm. In one group, with use of a 180 degrees algorithm, two series of reconstructed images were separated by 5 mm; artifact was observed on seven (11%) CT studies (on both series of images) and was located along the left or left anterior side of the aorta. CONCLUSION: To reduce the frequency of a spiral CT artifact that simulates aortic dissection, two series of segmented images can be reconstructed with a change of image position along the z axis of the aorta and use of a 180 degrees linear-interpolation algorithm.
This article has been cited by other articles:
![]() |
V. D. Raptopoulos, P. B. Boiselle, N. Michailidis, J. Handwerker, A. Sabir, J. A. Edlow, I. Pedrosa, and J. B. Kruskal MDCT Angiography of Acute Chest Pain: Evaluation of ECG-Gated and Nongated Techniques Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S346 - S356. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Katoh, J. E. Wildberger, R. W. Gunther, and A. Buecker Malignant Right Coronary Artery Anomaly Simulated by Motion Artifacts on MDCT Am. J. Roentgenol., October 1, 2005; 185(4): 1007 - 1010. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Flohr, S. Schaller, K. Stierstorfer, H. Bruder, B. M. Ohnesorge, and U. J. Schoepf Multi-Detector Row CT Systems and Image-Reconstruction Techniques Radiology, June 1, 2005; 235(3): 756 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-F. Ko, M.-J. Hsieh, M.-C. Chen, S.-H. Ng, F.-M. Fang, C.-C. Huang, Y.-L. Wan, and T.-Y. Lee Effects of Heart Rate on Motion Artifacts of the Aorta on Non-ECG-Assisted 0.5-Sec Thoracic MDCT Am. J. Roentgenol., April 1, 2005; 184(4): 1225 - 1230. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. K. Hofmann, K. H. Zou, P. Costello, and U. J. Schoepf Electrocardiographically Gated 16-Section CT of the Thorax: Cardiac Motion Suppression Radiology, December 1, 2004; 233(3): 927 - 933. [Abstract] [Full Text] [PDF] |
||||
![]() |
W de Monye, M Murphy, R Hodgson, J Holemans, and R Mcwilliams Acute aortic syndromes: pathology and imaging Imaging, August 1, 2004; 16(3): 230 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Morgan-Hughes, P. E. Owens, A. J. Marshall, and C. A. Roobottom Thoracic Aorta at Multi-Detector Row CT: Motion Artifact with Various Reconstruction Windows Radiology, August 1, 2003; 228(2): 583 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Yoshida, H. Akiba, M. Tamakawa, N. Yama, M. Hareyama, K. Morishita, and T. Abe Thoracic Involvement of Type A Aortic Dissection and Intramural Hematoma: Diagnostic Accuracy--Comparison of Emergency Helical CT and Surgical Findings Radiology, August 1, 2003; 228(2): 430 - 435. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Batra, B. Bigoni, J. Manning, D. R. Aberle, K. Brown, E. Hart, and J. Goldin Pitfalls in the Diagnosis of Thoracic Aortic Dissection at CT Angiography RadioGraphics, March 1, 2000; 20(2): 309 - 320. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Wang, E. Vidan, and G. W. Bergman Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR Angiography Radiology, December 1, 1999; 213(3): 751 - 758. [Abstract] [Full Text] |
||||
![]() |
C. Sebastia, E. Pallisa, S. Quiroga, A. Alvarez-Castells, R. Dominguez, and A. Evangelista Aortic Dissection: Diagnosis and Follow-up with Helical CT RadioGraphics, January 1, 1999; 19(1): 45 - 60. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Roos, J. K. Willmann, D. Weishaupt, M. Lachat, B. Marincek, and P. R. Hilfiker Thoracic Aorta: Motion Artifact Reduction with Retrospective and Prospective Electrocardiography-assisted Multi-Detector Row CT Radiology, January 1, 2002; 222(1): 271 - 277. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |