Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Loubeyre, P.
Right arrow Articles by Minh, V. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Loubeyre, P.
Right arrow Articles by Minh, V. A.

Radiology, Vol 205, 153-157, Copyright © 1997 by Radiological Society of North America


ARTICLES

Spiral CT artifact that simulates aortic dissection: image reconstruction with use of 180 degrees and 360 degrees linear- interpolation algorithms

P Loubeyre, E Angelie, F Grozel, H Abidi and VA Minh
Department of Radiology, Lyon-Sud Hospital, Pierre Benite, France.

PURPOSE: To evaluate a computed tomographic (CT) artifact that simulates aortic dissection. MATERIALS AND METHODS: Two groups of 65 patients underwent spiral CT of the chest for reasons other than suspected aortic dissection. In each group, two series of images (10-mm sections) were reconstructed with use of a 180 degrees or 360 degrees linear-interpolation algorithm. Series of images were read by two radiologists, and variance between interpretations was statistically measured. RESULTS: Among series of images, artifacts were seen on 21-26 (32%-40%) with use of a 180 degrees algorithm and 41 (63%) and 44 (68%) with use of a 360 degrees algorithm. Concordance between reviewers was fair (kappa = 0.58, 0.59) or good (kappa = 0.65) with use of a 180 degrees algorithm and excellent (kappa = 0.92) with use of a 360 degrees algorithm. In one group, with use of a 180 degrees algorithm, two series of reconstructed images were separated by 5 mm; artifact was observed on seven (11%) CT studies (on both series of images) and was located along the left or left anterior side of the aorta. CONCLUSION: To reduce the frequency of a spiral CT artifact that simulates aortic dissection, two series of segmented images can be reconstructed with a change of image position along the z axis of the aorta and use of a 180 degrees linear-interpolation algorithm.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
V. D. Raptopoulos, P. B. Boiselle, N. Michailidis, J. Handwerker, A. Sabir, J. A. Edlow, I. Pedrosa, and J. B. Kruskal
MDCT Angiography of Acute Chest Pain: Evaluation of ECG-Gated and Nongated Techniques
Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S346 - S356.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Katoh, J. E. Wildberger, R. W. Gunther, and A. Buecker
Malignant Right Coronary Artery Anomaly Simulated by Motion Artifacts on MDCT
Am. J. Roentgenol., October 1, 2005; 185(4): 1007 - 1010.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. G. Flohr, S. Schaller, K. Stierstorfer, H. Bruder, B. M. Ohnesorge, and U. J. Schoepf
Multi-Detector Row CT Systems and Image-Reconstruction Techniques
Radiology, June 1, 2005; 235(3): 756 - 773.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S.-F. Ko, M.-J. Hsieh, M.-C. Chen, S.-H. Ng, F.-M. Fang, C.-C. Huang, Y.-L. Wan, and T.-Y. Lee
Effects of Heart Rate on Motion Artifacts of the Aorta on Non-ECG-Assisted 0.5-Sec Thoracic MDCT
Am. J. Roentgenol., April 1, 2005; 184(4): 1225 - 1230.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. K. Hofmann, K. H. Zou, P. Costello, and U. J. Schoepf
Electrocardiographically Gated 16-Section CT of the Thorax: Cardiac Motion Suppression
Radiology, December 1, 2004; 233(3): 927 - 933.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
W de Monye, M Murphy, R Hodgson, J Holemans, and R Mcwilliams
Acute aortic syndromes: pathology and imaging
Imaging, August 1, 2004; 16(3): 230 - 239.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. J. Morgan-Hughes, P. E. Owens, A. J. Marshall, and C. A. Roobottom
Thoracic Aorta at Multi-Detector Row CT: Motion Artifact with Various Reconstruction Windows
Radiology, August 1, 2003; 228(2): 583 - 588.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Yoshida, H. Akiba, M. Tamakawa, N. Yama, M. Hareyama, K. Morishita, and T. Abe
Thoracic Involvement of Type A Aortic Dissection and Intramural Hematoma: Diagnostic Accuracy--Comparison of Emergency Helical CT and Surgical Findings
Radiology, August 1, 2003; 228(2): 430 - 435.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
P. Batra, B. Bigoni, J. Manning, D. R. Aberle, K. Brown, E. Hart, and J. Goldin
Pitfalls in the Diagnosis of Thoracic Aortic Dissection at CT Angiography
RadioGraphics, March 1, 2000; 20(2): 309 - 320.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Wang, E. Vidan, and G. W. Bergman
Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR Angiography
Radiology, December 1, 1999; 213(3): 751 - 758.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
C. Sebastia, E. Pallisa, S. Quiroga, A. Alvarez-Castells, R. Dominguez, and A. Evangelista
Aortic Dissection: Diagnosis and Follow-up with Helical CT
RadioGraphics, January 1, 1999; 19(1): 45 - 60.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. E. Roos, J. K. Willmann, D. Weishaupt, M. Lachat, B. Marincek, and P. R. Hilfiker
Thoracic Aorta: Motion Artifact Reduction with Retrospective and Prospective Electrocardiography-assisted Multi-Detector Row CT
Radiology, January 1, 2002; 222(1): 271 - 277.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.