Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rofsky, N. M.
Right arrow Articles by Weinreb, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rofsky, N. M.
Right arrow Articles by Weinreb, J. C.

Radiology, Vol 205, 163-169, Copyright © 1997 by Radiological Society of North America


ARTICLES

Peripheral vascular disease evaluated with reduced-dose gadolinium- enhanced MR angiography

NM Rofsky, G Johnson, MA Adelman, RJ Rosen, GA Krinsky and JC Weinreb
Department of Radiology, New York University Medical Center, NY 10016, USA.

PURPOSE: To demonstrate the utility of low-dose gadolinium-enhanced magnetic resonance (MR) angiography of two consecutive anatomic areas for assessment of peripheral vascular disease. MATERIALS AND METHODS: Fifteen patients underwent gadolinium-enhanced MR angiography for evaluation of lower extremity peripheral vascular disease after conventional digital subtraction angiography (DSA). MR angiography was performed with three-dimensional coronal gradient-echo acquisitions before and during administration of gadopentetate dimeglumine. Two separate, contiguous areas were studied with separate doses of 0.075 and 0.1 mmol/kg gadopentetate dimeglumine. MR angiography findings were compared with DSA findings; DSA was the standard of reference. Treatment options were determined first with MR angiograms and then with DSA images. RESULTS: For distinguishing greater than 50% stenosis from 50% or less stenosis, gadolinium-enhanced MR angiography yielded a sensitivity of 97%, a specificity of 96%, and an accuracy of 97%. In 146 (97%) of 150 anatomic segments, there was essential or total agreement on treatments determined with MR angiography and DSA. In two cases (one case of vascular stent placement and one case of surgical anastomosis), extent of disease was overestimated with MR angiography. The MR study of one infrapopliteal area was insufficient for evaluation. CONCLUSION: Accurate gadolinium-enhanced MR angiography of multiple peripheral vascular areas of the lower extremities can be performed in most patients with less than 0.2 mmol/kg contrast material.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. Poschenrieder, O. W. Hamer, T. Herold, T. Schleicher, I. Borisch, S. Feuerbach, and N. Zorger
Diagnostic Accuracy of Intraarterial and IV MR Angiography for the Detection of Stenoses of the Infrainguinal Arteries
Am. J. Roentgenol., January 1, 2009; 192(1): 117 - 121.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Habibi, M. S. Krishnam, D. G. Lohan, F. Barkhordarian, M. Jalili, R. S. Saleh, S. G. Ruehm, and J. P. Finn
High-Spatial-Resolution Lower Extremity MR Angiography at 3.0 T: Contrast Agent Dose Comparison Study
Radiology, August 1, 2008; 248(2): 680 - 692.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Zorger, M. Volk, O. W. Hamer, M. Lenhart, J. Seitz, B. Butz, and C. Paetzel
Intraarterial Gadolinium-Enhanced MR Angiography in Humans for the Detection of Infrainguinal Arterial Stenoses Before and After Percutaneous Angioplasty
Am. J. Roentgenol., October 1, 2005; 185(4): 867 - 872.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Janka, C. Fellner, E. Wenkel, W. Lang, W. Bautz, and F. A. Fellner
Contrast-enhanced MR Angiography of Peripheral Arteries including Pedal Vessels at 1.0 T: Feasibility Study with Dedicated Peripheral Angiography Coil
Radiology, April 1, 2005; 235(1): 319 - 326.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Vogt, W. Ajaj, P. Hunold, C. U. Herborn, H. H. Quick, J. F. Debatin, and S. G. Ruehm
Venous Compression at High-Spatial-Resolution Three-dimensional MR Angiography of Peripheral Arteries
Radiology, December 1, 2004; 233(3): 913 - 920.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. W. Olin, J. A. Kaufman, D. A. Bluemke, R. O. Bonow, M. D. Gerhard, M. R. Jaff, G. D. Rubin, and W. Hall
Atherosclerotic Vascular Disease Conference: Writing Group IV: Imaging
Circulation, June 1, 2004; 109(21): 2626 - 2633.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Ota, K. Takase, K. Igarashi, Y. Chiba, K. Haga, H. Saito, and S. Takahashi
MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images
Am. J. Roentgenol., January 1, 2004; 182(1): 201 - 209.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. Tatli, M. J. Lipton, B. D. Davison, R. B. Skorstad, and E. K. Yucel
From the RSNA Refresher Courses: MR Imaging of Aortic and Peripheral Vascular Disease
RadioGraphics, October 1, 2003; 23(90001): S59 - 78.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Wyttenbach, S. Gianella, M. Alerci, A. Braghetti, L. Cozzi, and A. Gallino
Prospective Blinded Evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced Peripheral MR Angiography, as Compared with Digital Subtraction Angiography
Radiology, April 1, 2003; 227(1): 261 - 269.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. V. Pandharipande, V. S. Lee, P. M. Reuss, H. W. Charles, R. J. Rosen, G. A. Krinsky, J. C. Weinreb, and N. M. Rofsky
Two-Station Bolus-Chase MR Angiography with a Stationary Table: A Simple Alternative to Automated-Table Techniques
Am. J. Roentgenol., December 1, 2002; 179(6): 1583 - 1589.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Loewe, M. Schoder, T. Rand, U. Hoffmann, J. Sailer, T. Kos, J. Lammer, and S. Thurnher
Peripheral Vascular Occlusive Disease: Evaluation with Contrast-Enhanced Moving-Bed MR Angiography Versus Digital Subtraction Angiography in 106 Patients
Am. J. Roentgenol., October 1, 2002; 179(4): 1013 - 1021.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Goyen, H. H. Quick, J. F. Debatin, M. E. Ladd, J. Barkhausen, C. U. Herborn, S. Bosk, H. Kuehl, M. Schleputz, and S. G. Ruehm
Whole-Body Three-dimensional MR Angiography with a Rolling Table Platform: Initial Clinical Experience
Radiology, July 1, 2002; 224(1): 270 - 277.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
J. W. Goldfarb, M. G. Hochman, D. S. Kim, and R. R. Edelman
Contrast-Enhanced MR Angiography and Perfusion Imaging of the Hand
Am. J. Roentgenol., November 1, 2001; 177(5): 1177 - 1182.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. U. Juergens, B. Tombach, P. Reimer, T. Vestring, and W. Heindel
Three-Dimensional Contrast-Enhanced MR Angiography of Endovascular Covered Stents in Patients with Peripheral Arterial Occlusive Disease
Am. J. Roentgenol., May 1, 2001; 176(5): 1299 - 1303.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
M. J. W. Koelemay, J. G. Lijmer, J. Stoker, D. A. Legemate, and P. M. M. Bossuyt
Magnetic Resonance Angiography for the Evaluation of Lower Extremity Arterial Disease: A Meta-analysis
JAMA, March 14, 2001; 285(10): 1338 - 1345.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. F. Glockner
Three-dimensional Gadolinium-enhanced MR Angiography: Applications for Abdominal Imaging
RadioGraphics, March 1, 2001; 21(2): 357 - 370.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. J. Nelemans, T. Leiner, H. C. W. de Vet, and J. M. A. van Engelshoven
Peripheral Arterial Disease: Meta-analysis of the Diagnostic Performance of MR Angiography
Radiology, October 1, 2000; 217(1): 105 - 114.
[Abstract] [Full Text]


Home page
RadiologyHome page
K. Visser and M. G. Myriam Hunink
Peripheral Arterial Disease: Gadolinium-enhanced MR Angiography versus Color-guided Duplex US-A Meta-analysis
Radiology, July 1, 2000; 216(1): 67 - 77.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
D. Weishaupt, S. G. Ruhm, C. A. Binkert, M. Schmidt, M. A. Patak, F. Steybe, S. McGill, and J. F. Debatin
Equilibrium-Phase MR Angiography of the Aortoiliac and Renal Arteries Using a Blood Pool Contrast Agent
Am. J. Roentgenol., July 1, 2000; 175(1): 189 - 195.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
V. S. Lee, D. J. Martin, G. A. Krinsky, and N. M. Rofsky
Gadolinium-Enhanced MR Angiography: Artifacts and Pitfalls
Am. J. Roentgenol., July 1, 2000; 175(1): 197 - 205.
[Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Leiner, K. Y. J.A.M. Ho, J. M.A. van Engelshoven, and Y. Watanabe
Techniques of Dynamic Subtraction Contrast-enhanced MR Angiography
RadioGraphics, July 1, 2000; 20(4): 1113 - 1114.
[Full Text] [PDF]


Home page
RadiologyHome page
N. M. Rofsky and M. A. Adelman
MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease
Radiology, February 1, 2000; 214(2): 325 - 338.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
K.-F. Kreitner, P. Kalden, A. Neufang, C. Duber, F. Krummenauer, E. Kustner, G. Laub, and M. Thelen
Diabetes and Peripheral Arterial Occlusive Disease: Prospective Comparison of Contrast-Enhanced Three-Dimensional MR Angiography with Conventional Digital Subtraction
Am. J. Roentgenol., January 1, 2000; 174(1): 171 - 179.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce
Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries
Circulation, November 30, 1999; 100(22): 2284 - 2301.
[Full Text] [PDF]


Home page
RadiologyHome page
E. Sueyoshi, I. Sakamoto, Y. Matsuoka, Y. Ogawa, H. Hayashi, R. Hashmi, and K. Hayashi
Aortoiliac and Lower Extremity Arteries: Comparison of Three-dimensional Dynamic Contrast-enhanced Subtraction MR Angiography and Conventional Angiography
Radiology, March 1, 1999; 210(3): 683 - 688.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.