Radiology, Vol 205, 163-169, Copyright © 1997 by Radiological Society of North America
ARTICLES |
NM Rofsky, G Johnson, MA Adelman, RJ Rosen, GA Krinsky and JC Weinreb
Department of Radiology, New York University Medical Center, NY 10016, USA.
PURPOSE: To demonstrate the utility of low-dose gadolinium-enhanced magnetic resonance (MR) angiography of two consecutive anatomic areas for assessment of peripheral vascular disease. MATERIALS AND METHODS: Fifteen patients underwent gadolinium-enhanced MR angiography for evaluation of lower extremity peripheral vascular disease after conventional digital subtraction angiography (DSA). MR angiography was performed with three-dimensional coronal gradient-echo acquisitions before and during administration of gadopentetate dimeglumine. Two separate, contiguous areas were studied with separate doses of 0.075 and 0.1 mmol/kg gadopentetate dimeglumine. MR angiography findings were compared with DSA findings; DSA was the standard of reference. Treatment options were determined first with MR angiograms and then with DSA images. RESULTS: For distinguishing greater than 50% stenosis from 50% or less stenosis, gadolinium-enhanced MR angiography yielded a sensitivity of 97%, a specificity of 96%, and an accuracy of 97%. In 146 (97%) of 150 anatomic segments, there was essential or total agreement on treatments determined with MR angiography and DSA. In two cases (one case of vascular stent placement and one case of surgical anastomosis), extent of disease was overestimated with MR angiography. The MR study of one infrapopliteal area was insufficient for evaluation. CONCLUSION: Accurate gadolinium-enhanced MR angiography of multiple peripheral vascular areas of the lower extremities can be performed in most patients with less than 0.2 mmol/kg contrast material.
This article has been cited by other articles:
![]() |
F. Poschenrieder, O. W. Hamer, T. Herold, T. Schleicher, I. Borisch, S. Feuerbach, and N. Zorger Diagnostic Accuracy of Intraarterial and IV MR Angiography for the Detection of Stenoses of the Infrainguinal Arteries Am. J. Roentgenol., January 1, 2009; 192(1): 117 - 121. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Habibi, M. S. Krishnam, D. G. Lohan, F. Barkhordarian, M. Jalili, R. S. Saleh, S. G. Ruehm, and J. P. Finn High-Spatial-Resolution Lower Extremity MR Angiography at 3.0 T: Contrast Agent Dose Comparison Study Radiology, August 1, 2008; 248(2): 680 - 692. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Zorger, M. Volk, O. W. Hamer, M. Lenhart, J. Seitz, B. Butz, and C. Paetzel Intraarterial Gadolinium-Enhanced MR Angiography in Humans for the Detection of Infrainguinal Arterial Stenoses Before and After Percutaneous Angioplasty Am. J. Roentgenol., October 1, 2005; 185(4): 867 - 872. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Janka, C. Fellner, E. Wenkel, W. Lang, W. Bautz, and F. A. Fellner Contrast-enhanced MR Angiography of Peripheral Arteries including Pedal Vessels at 1.0 T: Feasibility Study with Dedicated Peripheral Angiography Coil Radiology, April 1, 2005; 235(1): 319 - 326. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Vogt, W. Ajaj, P. Hunold, C. U. Herborn, H. H. Quick, J. F. Debatin, and S. G. Ruehm Venous Compression at High-Spatial-Resolution Three-dimensional MR Angiography of Peripheral Arteries Radiology, December 1, 2004; 233(3): 913 - 920. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Olin, J. A. Kaufman, D. A. Bluemke, R. O. Bonow, M. D. Gerhard, M. R. Jaff, G. D. Rubin, and W. Hall Atherosclerotic Vascular Disease Conference: Writing Group IV: Imaging Circulation, June 1, 2004; 109(21): 2626 - 2633. [Full Text] [PDF] |
||||
![]() |
H. Ota, K. Takase, K. Igarashi, Y. Chiba, K. Haga, H. Saito, and S. Takahashi MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images Am. J. Roentgenol., January 1, 2004; 182(1): 201 - 209. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Tatli, M. J. Lipton, B. D. Davison, R. B. Skorstad, and E. K. Yucel From the RSNA Refresher Courses: MR Imaging of Aortic and Peripheral Vascular Disease RadioGraphics, October 1, 2003; 23(90001): S59 - 78. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Wyttenbach, S. Gianella, M. Alerci, A. Braghetti, L. Cozzi, and A. Gallino Prospective Blinded Evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced Peripheral MR Angiography, as Compared with Digital Subtraction Angiography Radiology, April 1, 2003; 227(1): 261 - 269. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. V. Pandharipande, V. S. Lee, P. M. Reuss, H. W. Charles, R. J. Rosen, G. A. Krinsky, J. C. Weinreb, and N. M. Rofsky Two-Station Bolus-Chase MR Angiography with a Stationary Table: A Simple Alternative to Automated-Table Techniques Am. J. Roentgenol., December 1, 2002; 179(6): 1583 - 1589. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Loewe, M. Schoder, T. Rand, U. Hoffmann, J. Sailer, T. Kos, J. Lammer, and S. Thurnher Peripheral Vascular Occlusive Disease: Evaluation with Contrast-Enhanced Moving-Bed MR Angiography Versus Digital Subtraction Angiography in 106 Patients Am. J. Roentgenol., October 1, 2002; 179(4): 1013 - 1021. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Goyen, H. H. Quick, J. F. Debatin, M. E. Ladd, J. Barkhausen, C. U. Herborn, S. Bosk, H. Kuehl, M. Schleputz, and S. G. Ruehm Whole-Body Three-dimensional MR Angiography with a Rolling Table Platform: Initial Clinical Experience Radiology, July 1, 2002; 224(1): 270 - 277. [Abstract] [Full Text] |
||||
![]() |
J. W. Goldfarb, M. G. Hochman, D. S. Kim, and R. R. Edelman Contrast-Enhanced MR Angiography and Perfusion Imaging of the Hand Am. J. Roentgenol., November 1, 2001; 177(5): 1177 - 1182. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. U. Juergens, B. Tombach, P. Reimer, T. Vestring, and W. Heindel Three-Dimensional Contrast-Enhanced MR Angiography of Endovascular Covered Stents in Patients with Peripheral Arterial Occlusive Disease Am. J. Roentgenol., May 1, 2001; 176(5): 1299 - 1303. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. W. Koelemay, J. G. Lijmer, J. Stoker, D. A. Legemate, and P. M. M. Bossuyt Magnetic Resonance Angiography for the Evaluation of Lower Extremity Arterial Disease: A Meta-analysis JAMA, March 14, 2001; 285(10): 1338 - 1345. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Glockner Three-dimensional Gadolinium-enhanced MR Angiography: Applications for Abdominal Imaging RadioGraphics, March 1, 2001; 21(2): 357 - 370. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Nelemans, T. Leiner, H. C. W. de Vet, and J. M. A. van Engelshoven Peripheral Arterial Disease: Meta-analysis of the Diagnostic Performance of MR Angiography Radiology, October 1, 2000; 217(1): 105 - 114. [Abstract] [Full Text] |
||||
![]() |
K. Visser and M. G. Myriam Hunink Peripheral Arterial Disease: Gadolinium-enhanced MR Angiography versus Color-guided Duplex US-A Meta-analysis Radiology, July 1, 2000; 216(1): 67 - 77. [Abstract] [Full Text] |
||||
![]() |
D. Weishaupt, S. G. Ruhm, C. A. Binkert, M. Schmidt, M. A. Patak, F. Steybe, S. McGill, and J. F. Debatin Equilibrium-Phase MR Angiography of the Aortoiliac and Renal Arteries Using a Blood Pool Contrast Agent Am. J. Roentgenol., July 1, 2000; 175(1): 189 - 195. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, D. J. Martin, G. A. Krinsky, and N. M. Rofsky Gadolinium-Enhanced MR Angiography: Artifacts and Pitfalls Am. J. Roentgenol., July 1, 2000; 175(1): 197 - 205. [Full Text] [PDF] |
||||
![]() |
T. Leiner, K. Y. J.A.M. Ho, J. M.A. van Engelshoven, and Y. Watanabe Techniques of Dynamic Subtraction Contrast-enhanced MR Angiography RadioGraphics, July 1, 2000; 20(4): 1113 - 1114. [Full Text] [PDF] |
||||
![]() |
N. M. Rofsky and M. A. Adelman MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease Radiology, February 1, 2000; 214(2): 325 - 338. [Abstract] [Full Text] |
||||
![]() |
K.-F. Kreitner, P. Kalden, A. Neufang, C. Duber, F. Krummenauer, E. Kustner, G. Laub, and M. Thelen Diabetes and Peripheral Arterial Occlusive Disease: Prospective Comparison of Contrast-Enhanced Three-Dimensional MR Angiography with Conventional Digital Subtraction Am. J. Roentgenol., January 1, 2000; 174(1): 171 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries Circulation, November 30, 1999; 100(22): 2284 - 2301. [Full Text] [PDF] |
||||
![]() |
E. Sueyoshi, I. Sakamoto, Y. Matsuoka, Y. Ogawa, H. Hayashi, R. Hashmi, and K. Hayashi Aortoiliac and Lower Extremity Arteries: Comparison of Three-dimensional Dynamic Contrast-enhanced Subtraction MR Angiography and Conventional Angiography Radiology, March 1, 1999; 210(3): 683 - 688. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |