Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strecker, E. P.
Right arrow Articles by Gottmann, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strecker, E. P.
Right arrow Articles by Gottmann, D.

Radiology, Vol 205, 375-383, Copyright © 1997 by Radiological Society of North America


ARTICLES

Femoropopliteal artery stent placement: evaluation of long-term success

EP Strecker, IB Boos and D Gottmann
Department of Radiology, Diakonissen Hospital, Karlsruhe, Germany.

PURPOSE: To evaluate the long-term success of femoropopliteal artery stent placement after technical failure of balloon angioplasty and to determine potential factors predictive of stent failure. MATERIALS AND METHODS: In 80 patients, flexible tantalum stents were implanted for treatment of residual stenosis greater than 30% after balloon angioplasty of femoropopliteal artery stenoses (n = 33) or occlusions (n = 47). Follow-up examinations were performed at 1-72 months to evaluate early and late stent failure according to risk factors such as lesion type, anatomic location, stent length, runoff quality, and restenosis after balloon angioplasty. RESULTS: Early stent thrombosis occurred within 10 days after stent placement in four (5%) patients; the frequency was higher (P < .01) in stents longer than 4 cm (14%) versus that in stents 4 cm or shorter (2%). For all stents, the 2-year primary patency rate was 51% and the 3-year rate was 48%. The 2-year primary patency rate was significantly better (P < .05) for shorter stents (59%) versus that for longer stents (30%) and for treated stenoses (73%) versus treated occlusions (33%). Multivariate analysis revealed that lesion type and lesion length were the most reliable factors predictive of stent failure. CONCLUSION: Successful stent therapy does not seem to depend on the type of stent used but rather on lesion type, lesion length, and other predisposing factors.


This article has been cited by other articles:


Home page
Vasc MedHome page
T. Zeller
Current state of endovascular treatment of femoro-popliteal artery disease
Vascular Medicine, August 1, 2007; 12(3): 223 - 234.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
R. Bonvini, I. Baumgartner, D. D. Do, M. Alerci, J.-M. Segatto, P. Tutta, K. Jager, M. Aschwanden, E. Schneider, B. Amann-Vesti, et al.
Late acute thrombotic occlusion after endovascular brachytherapy and stenting of femoropopliteal arteries
J. Am. Coll. Cardiol., February 5, 2003; 41(3): 409 - 412.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. S. R. Muradin, J. L. Bosch, T. Stijnen, and M. G. M. Hunink
Balloon Dilation and Stent Implantation for Treatment of Femoropopliteal Arterial Disease: Meta-Analysis
Radiology, October 1, 2001; 221(1): 137 - 145.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
I. L. Gordon, R. M. Conroy, M. Arefi, J. M. Tobis, E. A. Stemmer, and S. E. Wilson
Three-Year Outcome of Endovascular Treatment of Superficial Femoral Artery Occlusion
Arch Surg, February 1, 2001; 136(2): 221 - 228.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Lammer, M. D. Dake, J. Bleyn, B. T. Katzen, M. Cejna, P. Piquet, G. J. Becker, and R. A. Settlage
Peripheral Arterial Obstruction: Prospective Study of Treatment with a Transluminally Placed Self-expanding Stent-Graft
Radiology, October 1, 2000; 217(1): 95 - 104.
[Abstract] [Full Text]


Home page
RadiologyHome page
P. H. Rolland, A.-B. Charifi, C. Verrier, H. Bodard, A. Friggi, P. Piquet, G. Moulin, and J.-M. Bartoli
Hemodynamics and Wall Mechanics after Stent Placement in Swine Iliac Arteries: Comparative Results from Six Stent Designs
Radiology, October 1, 1999; 213(1): 229 - 246.
[Abstract] [Full Text]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
R. J. Powell and D. B. Walsh
Lesions of the Superficial Femoral Artery: Which Ones Need Treatment and How
Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1999; 10(2): 119 - 132.
[Abstract] [PDF]


Home page
RadiologyHome page
H. F. Lugmayr, H. Holzer, M. Kastner, H. Riedelsberger, and A. Auterith
Treatment of Complex Arteriosclerotic Lesions with Nitinol Stents in the Superficial Femoral and Popliteal Arteries: A Midterm Follow-up
Radiology, January 1, 2002; 222(1): 37 - 43.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.