Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhang, M.
Right arrow Articles by Kono, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhang, M.
Right arrow Articles by Kono, M.

Radiology, Vol 205, 471-478, Copyright © 1997 by Radiological Society of North America


ARTICLES

Solitary pulmonary nodules: evaluation of blood flow patterns with dynamic CT

M Zhang and M Kono
Department of Radiology, Kobe University School of Medicine, Japan.

PURPOSE: To evaluate the efficacy of dynamic computed tomography (CT) for differentiating benign from malignant solitary pulmonary nodules (SPNs). MATERIALS AND METHODS: Sixty-five patients with noncalcified SPNs (diameter, < or = 30 mm; 42 malignant, 16 benign, seven inflammatory) underwent single-location dynamic contrast material- enhanced (100 mL, 4 mL/sec) serial CT. Peak height of time-attenuation curves and ratio of peak height of the SPN to that of the aorta were measured. Precontrast attenuation and enhancement pattern were recorded. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. RESULTS: Peak heights of malignant (41.9 HU +/- 2.8) and inflammatory (43.6 HU +/- 7.7) SPNs were significantly higher than that (13.4 HU +/- 2.2) of benign SPNs (P < .001; P < .01). SPN-to-aorta ratios in malignant and inflammatory SPNs were significantly higher than that in benign SPNs (P < .001, P < .05). No statistically significant differences in the peak height and SPN-to-aorta ratio were found between malignant and inflammatory SPNs. Precontrast attenuation of inflammatory SPNs was lower than that of malignant SPNs (P < .05). Perfusion values in malignant and inflammatory SPNs were significantly higher than that of the benign SPNs (P < .01). CONCLUSION: Dynamic CT provides quantitative information about blood flow patterns of SPNs and is an applicable diagnostic method for differentiating SPNs.


This article has been cited by other articles:


Home page
RadiologyHome page
E. J. Chae, J.-W. Song, J. B. Seo, B. Krauss, Y. M. Jang, and K.-S. Song
Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience
Radiology, November 1, 2008; 249(2): 671 - 681.
[Abstract] [Full Text] [PDF]


Home page
Postgrad. Med. J.Home page
A O Soubani
The evaluation and management of the solitary pulmonary nodule
Postgrad. Med. J., September 1, 2008; 84(995): 459 - 466.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Zou, M. Zhang, Q. Wang, D. Shang, L. Wang, and G. Yu
Quantitative Investigation of Solitary Pulmonary Nodules: Dynamic Contrast-Enhanced MRI and Histopathologic Analysis
Am. J. Roentgenol., July 1, 2008; 191(1): 252 - 259.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Cronin, B. A. Dwamena, A. M. Kelly, and R. C. Carlos
Solitary Pulmonary Nodules: Meta-analytic Comparison of Cross-sectional Imaging Modalities for Diagnosis of Malignancy
Radiology, March 1, 2008; 246(3): 772 - 782.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. Honda, T. Johkoh, H. Sumikawa, A. Inoue, N. Tomiyama, N. Mihara, Y. Fujita, M. Tsubamoto, M. Yanagawa, T. Daimon, et al.
Pulmonary Nodules: 3D Volumetric Measurement with Multidetector CT Effect of Intravenous Contrast Medium
Radiology, December 1, 2007; 245(3): 881 - 887.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. K. Gould, J. Fletcher, M. D. Iannettoni, W. R. Lynch, D. E. Midthun, D. P. Naidich, and D. E. Ost
Evaluation of Patients With Pulmonary Nodules: When Is It Lung Cancer?: ACCP Evidence-Based Clinical Practice Guidelines (2nd Edition)
Chest, September 1, 2007; 132(3_suppl): 108S - 130S.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H Bolte, C Riede, S Muller-Hulsbeck, S Freitag-Wolf, G Kohl, T Drews, M Heller, and J Bieder
Precision of computer-aided volumetry of artificial small solid pulmonary nodules in ex vivo porcine lungs
Br. J. Radiol., June 1, 2007; 80(954): 414 - 421.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. Goh, S. Halligan, S. A. Taylor, D. Burling, P. Bassett, and C. I. Bartram
Differentiation between Diverticulitis and Colorectal Cancer: Quantitative CT Perfusion Measurements versus Morphologic Criteria--Initial Experience
Radiology, February 1, 2007; 242(2): 456 - 462.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Kono, K. Fujimoto, H. Terasaki, N. L. Muller, S. Kato, J. Sadohara, N. Hayabuchi, and S. Takamori
Dynamic MRI of Solitary Pulmonary Nodules: Comparison of Enhancement Patterns of Malignant and Benign Small Peripheral Lung Lesions
Am. J. Roentgenol., January 1, 2007; 188(1): 26 - 36.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. J. Jeong, C. A. Yi, and K. S. Lee
Solitary Pulmonary Nodules: Detection, Characterization, and Guidance for Further Diagnostic Workup and Treatment
Am. J. Roentgenol., January 1, 2007; 188(1): 57 - 68.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. T. Winer-Muram
The solitary pulmonary nodule.
Radiology, April 1, 2006; 239(1): 34 - 49.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. H. McCollough, M. R. Bruesewitz, and J. M. Kofler Jr
CT Dose Reduction and Dose Management Tools: Overview of Available Options.
RadioGraphics, March 1, 2006; 26(2): 503 - 512.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. J. Jeong, K. S. Lee, S. Y. Jeong, M. J. Chung, S. S. Shim, H. Kim, O J. Kwon, and S. Kim
Solitary Pulmonary Nodule: Characterization with Combined Wash-in and Washout Features at Dynamic Multi-Detector Row CT
Radiology, November 1, 2005; 237(2): 675 - 683.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. F. Machado, D. Laskowski, O. Deffenderfer, T. Burch, S. Zheng, P. J. Mazzone, T. Mekhail, C. Jennings, J. K. Stoller, J. Pyle, et al.
Detection of Lung Cancer by Sensor Array Analyses of Exhaled Breath
Am. J. Respir. Crit. Care Med., June 1, 2005; 171(11): 1286 - 1291.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Matsuoka, Y. Kurihara, K. Yagihashi, H. Niimi, and Y. Nakajima
Peripheral Solitary Pulmonary Nodule: CT Findings in Patients with Pulmonary Emphysema
Radiology, April 1, 2005; 235(1): 266 - 273.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. V. Sahani, S. P. Kalva, L. M. Hamberg, P. F. Hahn, C. G. Willett, S. Saini, P. R. Mueller, and T.-Y. Lee
Assessing Tumor Perfusion and Treatment Response in Rectal Cancer with Multisection CT: Initial Observations
Radiology, March 1, 2005; 234(3): 785 - 792.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Mattioli, F. D'Ovidio, N. Daddi, L. Ferruzzi, V. Pilotti, A. Ruffato, R. Bolzani, and G. Gavelli
Transthoracic Endosonography for the Intraoperative Localization of Lung Nodules
Ann. Thorac. Surg., February 1, 2005; 79(2): 443 - 449.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
Y.-Y. Yau, W.-S. Chan, Y.-M. Tam, P. Vernon, S. Wong, M. Coel, and S. K.-F. Chu
Application of Intravenous Contrast in PET/CT: Does It Really Introduce Significant Attenuation Correction Error?
J. Nucl. Med., February 1, 2005; 46(2): 283 - 291.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. A Yi, K. S. Lee, E. A Kim, J. Han, H. Kim, O J. Kwon, Y. J. Jeong, and S. Kim
Solitary Pulmonary Nodules: Dynamic Enhanced Multi-Detector Row CT Study and Comparison with Vascular Endothelial Growth Factor and Microvessel Density
Radiology, October 1, 2004; 233(1): 191 - 199.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. F. Schaefer, J. Vollmar, F. Schick, R. Vonthein, M. D. Seemann, H. Aebert, R. Dierkesmann, G. Friedel, and C. D. Claussen
Solitary Pulmonary Nodules: Dynamic Contrast-enhanced MR Imaging--Perfusion Differences in Malignant and Benign Lesions
Radiology, August 1, 2004; 232(2): 544 - 553.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K A Miles
Perfusion CT for the assessment of tumour vascularity: which protocol?
Br. J. Radiol., December 1, 2003; 76(suppl_1): S36 - S42.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
D. Ost, A. M. Fein, and S. H. Feinsilver
The Solitary Pulmonary Nodule
N. Engl. J. Med., June 19, 2003; 348(25): 2535 - 2542.
[Full Text] [PDF]


Home page
RadiologyHome page
K. Fujimoto, T. Abe, N. L. Muller, H. Terasaki, S. Kato, J. Sadohara, R. Kono, O. Edamitsu, T. Ishitake, A. Hayashi, et al.
Small Peripheral Pulmonary Carcinomas Evaluated with Dynamic MR Imaging: Correlation with Tumor Vascularity and Prognosis
Radiology, June 1, 2003; 227(3): 786 - 793.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K A Miles and M R Griffiths
Perfusion CT: a worthwhile enhancement?
Br. J. Radiol., April 1, 2003; 76(904): 220 - 231.
[Full Text] [PDF]


Home page
ChestHome page
U. Tateishi, M. Kusumoto, Y. Akiyama, F. Kishi, M. Nishimura, and N. Moriyama
Role of Contrast-Enhanced Dynamic CT in the Diagnosis of Active Tuberculoma
Chest, October 1, 2002; 122(4): 1280 - 1284.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Ohno, H. Hatabu, D. Takenaka, S. Adachi, M. Kono, and K. Sugimura
Solitary Pulmonary Nodules: Potential Role of Dynamic MR Imaging in Management—Initial Experience
Radiology, August 1, 2002; 224(2): 503 - 511.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
C. Schaefer-Prokop and M. Prokop
New imaging techniques in the treatment guidelines for lung cancer
Eur. Respir. J., February 1, 2002; 19(35_suppl): 71S - 83s.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. A. Miles, M. R. Griffiths, and M. A. Fuentes
Standardized Perfusion Value: Universal CT Contrast Enhancement Scale that Correlates with FDG PET in Lung Nodules
Radiology, August 1, 2001; 220(2): 548 - 553.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. OST and A. FEIN
Evaluation and Management of the Solitary Pulmonary Nodule
Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 782 - 787.
[Full Text]


Home page
RadiologyHome page
S. J. Swensen, R. W. Viggiano, D. E. Midthun, N. L. Müller, A. Sherrick, K. Yamashita, D. P. Naidich, E. F. Patz, T. E. Hartman, J. R. Muhm, et al.
Lung Nodule Enhancement at CT: Multicenter Study1
Radiology, January 1, 2000; 214(1): 73 - 80.
[Abstract] [Full Text]


Home page
ChestHome page
D. D. Maki, W. B. Gefter, and A. Alavi
Recent Advances in Pulmonary Imaging
Chest, November 1, 1999; 116(5): 1388 - 1402.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Silverman, K. Tuncali, D. F. Adams, R. D. Nawfel, K. H. Zou, and P. F. Judy
CT Fluoroscopy-guided Abdominal Interventions: Techniques, Results, and Radiation Exposure
Radiology, September 1, 1999; 212(3): 673 - 681.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1997 by the Radiological Society of North America.